DMX Address
To select the DMX Address, press the E TER button to show DMX ADDRESS on the display. Use the DOW /UP button to adjust the address from 1
to 512. Once the address has been selected, press the E TER button to setup, to go back to the functions without any changes press the ME U button
again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Setup
To select Setup press the E TER button to confirm, use the UP/DOW button to select DMX Modes, Dimmer Settings, Output Modes, Data Input,
Ethernet Interface, Display Setting or Frequency.
DMX Modes
To select the DMX Modes, press the E TER button to show DMX Modes on the display. Use the DOW /UP button to select the Mode1, Mode2, Mode3,
Mode4 or Mode5. Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press the
ME U button again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Dimmer Settings
To select the Dimmer Settings, press the E TER button to show Dimmer Settings on the display. Use the DOW /UP button to select the Dimmer
Curve or Dimmer Speed. Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press
the ME U button again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Dimmer Curve
To select the Dimmer Curve, press the E TER button to show Dimmer Curve on the display. Use the DOW /UP button to select the Quadratic, Linear,
Inv.square or S Curve. Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press the
ME U button again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
DIMMER CURVES
Curve 1 - Linear:
The increase in light intensity appears to be linear as DMX value is increased.
Curve 2 - Quadratic:
ight intensity control is finer at low levels and coarser at high levels.
Curve 3 - Inverse Square:
ight intensity control is coarser at low levels and finger at high levels.
Curve 4 - (S-curve):
ight intensity control is finer at low levels and high levels and coarser at medium levels.
Dimmer Speed
To select the Dimmer Speed, press the E TER button to show Dimmer Speed on the display. Use the DOW /UP button to select the Fast or Smooth.
Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press the ME U button again.
Hold and press the ME U button for one second or wait for one
Output Modes
To select the Output Modes, press the E TER button to show Output Modes on the display. Use the DOW /UP button to select the Boost, Regulated,
Silent or Ultra Silent. Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press the
ME U button again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Data Input
To select the Data Input, press the E TER button to show Data Input on the display. Use the DOW /UP button to select the Auto, DMX or Art- et.
Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes press the ME U button again.
Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Ethernet interface
To select the Ethernet Interface, press the E TER button to show Ethernet Interface on the display. Use the DOW /UP button to select the etwork,
Art-net or Repeat on DMX. Once the mode has been selected, press the E TER button to setup, to go back to the functions without any changes
press the ME U button again. Hold and press the ME U button for one second or wait for one minute to exit the menu mode.
Linear Quadratic Inverse Square S-curve