Parker Hannifin Corporation
Instrumentation Valve Division
Jacksonville, Alabama
MI-101
DISASSEMBLY
WARNING: MAKE CERTAIN THE SYSTEM IN WHICH THE VALVE IS INSTALLED IS DRAINED AND/OR EXHAUSTED
OF ALL PRESSURE BEFORE STARTING VALVE REMOVAL OR DISASSEMBLY. FAILURE TO DO SO CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
1. Verify that the Toggle Needle Valve Maintenance Kit being used is appropriate for the Valves size, Stem Seat, and
service requirements. Always contact your authorized Parker representative if any questions arise.
2. Open the Valve by actuating the Handle such that it is parallel to the Valve Stem.
3. Remove the Panel Nut (if applicable) by turning counter-clockwise with the appropriate wrench:
V Q 11/16 inch hex wrench
V6Q 3/16 inch hex wrench
. Remove the Valve from its mounting panel (if applicable).
5. Close the valve, then remove and discard the Handle Spring Pin by lightly tapping the Spring Pin with a 3/6 inch
diameter punch. Gently remove the Handle by pulling it from the Stem.
6. Refer to Figure 2. Remove the Handle Washer located directly above the Cap. Set this piece aside for later
reassembly.
7. Remove the Cap by turning counter-clockwise with the appropriate wrench as noted below:
V Q 5/8 inch hex wrench
V6Q 3/ inch hex wrench
8. Gently remove the Stem Sub-Assembly and components from the Cap.
9. Remove the Stem Washer and Spring. Discard the Stem Washer.
10.Remove and discard the Stem O-Ring.
11.Discard the Stem Sub-Assembly.
REASSEMBLY
1. Make certain all parts are free of dirt or other contamination before starting reassembly of the Valve.
2. Apply a liberal amount of lubricant, as consistent with the valves service requirements, to the Stem O-Ring. Always
contact your authorized Parker representative if questions arise.
3. Refer to Figure 2. Stack the components listed below on the Stem Sub-Assembly in the following order, with the
first item being placed directly above the landing on the Stem.
A) Spring
B) Stem Washer
C) O-Ring, lubricated.
. Gently insert the modified Stem Sub-Assembly (from Step 3) through the stem hole in the Cap until the modified
Stem Sub-Assembly has bottomed-out in the Cap. NOTE: Exercise extreme care not to damage the O-Ring.
5. Install the Cap on the Body by turning clockwise until two or three threads are engaged, and torque as follows:
Val e Size Brass Val e Bodies Stainless Steel Bodies
V Q 100 in-lbs (11.3 N-m) 175 in-lbs (19.7 N-m)
V6Q 100 in-lbs (11.3 N-m) 300 in-lbs ((33.8 N-m)
6. Place the Handle Washer over the Stem.
7. Install the Handle on the Stem at right-angles with respect to the Stem. Align the Handles pin-attachment hole with
the corresponding hole in the Stem.
8. Gently install the Spring Pin in the Handles pin-attachment hole.
NOTE: A minimum gap of 1/32 inch (0.03125) must exist between the Handle and Handle Washer.
9. Actuate the Toggle Valve Handle through at least one (1) Open and Close cycle to verify proper operation of the
Handle.
10.Rebuild the Toggle Valve if it exhibits rough or irregular Handle operation. Always contact your authorized Parker
representative if questions arise.
11.Place the Valve in its mounting panel hole, if applicable, by turning the Panel Nut clockwise with the appropriate
wrench.
V Q 11/16 inch hex wrench
V6Q 13/16 inch hex wrench
3