manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Philips
  6. •
  7. Lighting Equipment
  8. •
  9. Philips ED-37 User manual

Philips ED-37 User manual

QOrdering Information
Ordering Code CDM350/V/O/PS/4K/ALTO
ANSI Designation M171/O, M131/O
Product Number 132571
Description MasterColor Pulse Start
Ceramic Metal Halide
Package Quantity 6
QPhysical Characteristics
Bulb Size ED-37
Bulb Finish Clear
Base Extended Eyelet
Mogul Screw (EX39)
Max. Overall Length (MOL) 11.5 (292mm)
Light Center Length (LCL) 7.0 (178mm)
Arc Length 24mm
Arc Tube Material Polycrystalline Alumina
Max. Permissible Bulb Temp. 400°C (752°F)
Max. Permissible Base Temp. 210°C (410°F)
Maximum Bulb to Base Eccentricity 3º
Maximum Arc Tube to Base Eccentricity 3º
QOperating Characteristics (Photometric)
ated Initial Lumens131,500
Mean Lumens,Approx.225,200
ated Average Life, Hours 24,000
Correlated Color Temp. (CCT)24200K
CIE Chromaticity Approx.2x-.371, y-.372
Color endering Index (C I) 90
Efficacy (lpw) 90
QOperating Position
Vertical ± 15°-Open or Enclosed Luminiares
CDM 350/C/V/O/PS/4K/ALTO
Lumen Maintenance
BURNING HOURS
RATED AVERAGE LIFE 24,000 HOURS
80%
100%
60%
40%
20%
0% 0 5000 10,000 15,000 20,000 24,000
% LUMEN
MAINTENANCE
Patented coil design
offers protectionfor
open fixture rating
Patented dual frame
offers improved life
and reliability
MasterColor®Pulse Start Ceramic Metal Halide
350 Watt ED-37 (Clear) Lamp
featuring ALTO®Lamp Technology
MasterColor®Pulse Start Ceramic Metal Halide 350 Watt ED-37 (Clear) Lamp featuring ALTO®LampTechnology
Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Lamp Operating Voltage (rms) (Nominal) 2............150
Initial Lamp Voltage Range (rms) 3....................135-165
Lamp Operating Current (Amps) (rms) (Nominal) . . . . . 2.83
Lamp Current Crest Factor ( aximum) . . . . . . . . . . . . . . 1.6
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . . . . 5 inutes
Restrike Time for Hot Lamp. . . . . . . . . . . . . . . . . . . . . . . . . 15 inutes
Ballast Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI 171/ 131/O
Ballast Open Circuit Voltage ( inimum). . . . . . . . . . . . . . . 254 R S in.
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 inimum, 4000 aximum
Pulse Width @ 90% Peak (2700 Volts) . . . . . . . . . . . . . . . . 1.3 icro Second inimum
Pulse Repetition Rate ( inimum) . . . . . . . . . . . . . . . . . . . . 1 per Half Cycle
inimum Operating Temperature . . . . . . . . . . . . . . . . . . . . -30º C (-22°F)
1) easured at 100 hrs of life in vertical position.
2) easured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
3) easured with the lamp operating at rated watts.
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
ADivision of Philips Electronics North America Corporation
Updated 5/07 TDS-132571
Philips Lighting
281 Hillmount oad
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
ADivision of Philips Electronics Ltd.
www.philips.com
Warnings, Cautions and Operating Instructions
“WA NING: These lamps can cause serious
skin burn and eye inflammation from short wave
ultraviolet radiation if outer envelope of the lamp is
broken or punctured. Do not use where people will
remain for more than a few minutes unless adequate
shielding or other safety precautions are used. Certain
lamps that will automatically extinguish when the outer
envelope is broken or punctured are commercially
available.”This lamp complies with FDA radiation
performance standard 21 CFR subchapter J.
(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off
at once and replace the lamp to avoid possible
injury from hazardous short wave ultraviolet
radiation.Do not scratch the outer bulb or subject
it to pressure as this could cause the outer bulb to
crack or shatter.A partial vacuum in the outer
bulb may cause glass to fly if the envelope is struck.
WA NING: The arc-tube of metal halide lamps
are designed to operate under high pressure and at
temperatures up to 1000º C and can unexpectedly
rupture due to internal or external factors such as a
ballast failure or misapplication. If the arc-tube ruptures
for any reason, the outer bulb may break and pieces of
extremely hot glass might be discharged into the
surrounding environment. If such a rupture were
to happen, THE E IS A ISK OF PE SONAL
INJU Y, P OPE TY DAMAGE, BU NS
AND FI E.
These lamps are designed to retain all the
glass particles should an arc tube rupture
occur.The following operating instructions are
recommended to minimize these occurrences.
ELAMP FIXTU ES AT O BEFO ETHE END
OF ATED LIFE.Allowing lamps to operate
until they fail is not advised and may increase
the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling
gas containing Kr-85 and is distributed by
Philips Lighting Company, a division of Philips
Electronics North America Corporation,
Somerset, New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL
INJURY, PROPERTY DA AGE, BURNS AND FIRE
RESULTING FRO AN ARC-TUBE RUPTURE
THE FOLLOWING LAMP OPE ATING
INST UCTIONS UST BE FOLLOWED:
LAMP OPE ATING INST UCTIONS:
1. RELA P FIXTURES AT OR BEFORE THE END OF
RATED LIFE. Allowing lamps to operate until they fail is
not advised and may increase the possibility of inner arc
tube rupture.
2. Before lamp installation/replacement, shut power off and
allow lamp and fixture to cool to avoid electrical shock
and potential burn hazards.
3. Use only auxiliary equipment meeting Philips
and/or ANSI standards. Use within voltage limits
recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers
electrical data.
C. All Pulse Start mogul based lamps require a socket
rated to withstand a 4000 volt pulse.
4. Periodically inspect the outer envelope. Replace any
lamps that show scratches, cracks or damage.
5. If a lamp bulb support is used, be sure to insulate the
support electrically to avoid possible decomposition of
the bulb glass.
6. Protect lamp base, socket and wiring against moisture,
corrosive atmospheres and excessive heat.
7. Time should be allowed for lamps to stabilize in color
when turned on for the first time. This may require
several hours of operation, with more than one start.
Lamp color is also subject to change under conditions
of excess vibration or shock, and color appearance may
vary between individual lamps.
8. Lamps may require 10 to 20 minutes to re-light if there
is a power interruption.
9. Take care in handling and disposing of lamps. If an
arc tube is broken, avoid skin contact with any of the
contents or fragments.
10. Use this lamp only in fixtures that contain Pulse Start
metal halide ballasts and are specifically
designed for
use with Pulse Start metal halide lamps.
WA NINGS, CAUTIONS AND OPE ATING INST UCTIONS for Protected MasterColor®Pulse Start
Ceramic Metal Halide Lamps (Vertical Operation ± 15°, Open or Enclosed Fixtures )

This manual suits for next models

1

Other Philips Lighting Equipment manuals

Philips CityTouch OLC NEMA SR LLC7280 User manual

Philips

Philips CityTouch OLC NEMA SR LLC7280 User manual

Philips GreenPower TLED InstantFit User manual

Philips

Philips GreenPower TLED InstantFit User manual

Philips 56492-31-16 User manual

Philips

Philips 56492-31-16 User manual

Philips Selecon User manual

Philips

Philips Selecon User manual

Philips ColorBlast TRX User manual

Philips

Philips ColorBlast TRX User manual

Philips Selecon SPX 15-35 User manual

Philips

Philips Selecon SPX 15-35 User manual

Philips TT155 User guide

Philips

Philips TT155 User guide

Philips 56454-17-16 User manual

Philips

Philips 56454-17-16 User manual

Philips Ecomoods 40339/**/16 Series User manual

Philips

Philips Ecomoods 40339/**/16 Series User manual

Philips bodine B30 User manual

Philips

Philips bodine B30 User manual

Philips SL ePAR 180 LED Luminaire User manual

Philips

Philips SL ePAR 180 LED Luminaire User manual

Philips 59510-17-16 User manual

Philips

Philips 59510-17-16 User manual

Philips Arcitone 57985/31/16 User manual

Philips

Philips Arcitone 57985/31/16 User manual

Philips Lightolier SQ6-3 User manual

Philips

Philips Lightolier SQ6-3 User manual

Philips 910503700745 User manual

Philips

Philips 910503700745 User manual

Philips Ligholier KUBIK 1.0 SL110A User manual

Philips

Philips Ligholier KUBIK 1.0 SL110A User manual

Philips VARI-Lite VL4000 User manual

Philips

Philips VARI-Lite VL4000 User manual

Philips Disney Softpal Sulley User manual

Philips

Philips Disney Softpal Sulley User manual

Philips 56420-31-16 User manual

Philips

Philips 56420-31-16 User manual

Philips UrbanSpark User manual

Philips

Philips UrbanSpark User manual

Philips eW Flex Compact User manual

Philips

Philips eW Flex Compact User manual

Philips RS772B User manual

Philips

Philips RS772B User manual

Philips LED Luminaires User manual

Philips

Philips LED Luminaires User manual

Philips Hue Runner User manual

Philips

Philips Hue Runner User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.