Reliable GFR Series User manual

Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model GFR
Model GFR Recessed
Quick Response
Sprinklers
Bulletin 131 Rev. M
Bulletin 131 Rev. M
Model GFR Sprinkler Types
Standard Upright
Standard Pendent
Horizontal Sidewall
HSW1 Deflector
Intermediate Level Upright
Intermediate Level Pendent
Conventional
Model GFR Recessed
Sprinkler Types
Recessed Pendent
Recessed Horizontal Sidewall
HSW1 Deflector
Approvals
1. Underwriters Laboratories, Inc. (UL)
2. Underwriters’ Laboratories of Canada (ULC)
3. NYC BS&A No. 587-75-SA
4. Factory Mutual Approvals (FM)
5. .....
6. MIL-S-901C and MIL-STD-167-1
7. NYC MEA 258-93-E
UL Listing Category
Sprinklers, Automatic & Open
Quick Response Sprinkler
UL Guide Number
VNIV
Product Description
Reliable Models GFR and GFR Recessed Sprinklers are
Quick Response fusible solder type automatic sprinklers.
These sprinklers have demonstrated response times in
laboratory tests which are five times faster than standard
response sprinklers.
This quick response enables the Models GFR and GFR
Recessed Sprinklers to apply water to a fire much faster
than standard response sprinklers of the same temperature
rating.
Application
Quick response sprinklers are used in fixed fire protec-
tion systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflec-
tor style and sprinkler spacing are in accordance with the
latest published standards of the National Fire Protection
Association or the approving Authority Having Jurisdic-
tion. Quick response sprinklers are intended for standard
area coverage and standard water densities as specified
in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
Upright Pendent Intermediate Level
Upright
Intermediate Level
Pendent
Small Orifice
Upright
Conventional Recessed
Horizontal Sidewall
HSW-1 Deflector
Horizontal Sidewall
HSW-1 Deflector
Recessed
Pendent
Recessed FP
Pendent
2.
Model GFR Quick Response Upright, Pendent & Conventional Sprinklers
Model GFR Quick Response Upright & Pendent Intermediate Level Sprinklers
Installation Wrench: Model W2 Sprinkler Wrench
Installation Data:
Sprinkler Type
Nominal K
Factor
Sprinkler
Height Approvals
Sprinkler
Identification
Numbers (SIN)
US Metric SSU SSP
Standard-Upright (SSU) and Pendent (SSP)
Deflectors Marked to Indicate Position
5.6
4.2
2.8
4.2
8.0
80
60
40
60
115
27
/
8” (73mm)
27
/
8” (73mm)
27
/
8” (73mm)
73mm
215
/
16” (75mm)
1,2,3,6,7
1,2,3,6,7
1,2,3,7
-------------
1,2,3,4,7
R3125
R3123
R3121
R3124
R3127
R3115
R3113
R3111
R3114
R3117
1/2” (15mm) Standard Orifice with ½” NPT (R½) Thread
7
/
16” (11mm) Small Orifice with ½” NPT (R½) Thread (11mm)
3
/
8” (10mm) Small Orifice with ½” NPT (R½) Thread (10mm)
10mm Orifice XLH with R3
/
8Thread
17
/
32” (20mm) Large Orifice with ¾” NPT (R¾) Thread
Conventional-Install in Upright or Pendent Position
4.2
5.6
60
80
73mm
73mm
-------------
-------------
R3174
R3175
10mm Orifice XLH with R3
/
8Thread
15mm Standard Orifice with ½” NPT (R½) Thread
Installation Wrench: Model W2 Sprinkler Wrench Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Sprinkler Type
Nominal K
Factor Sprinkler
Height Approvals
Sprinkler
Identification
Number (SIN)
US Metric SSU SSP
Standard Upright (SSU) and Pendent (SSP)
Deflectors Marked to Indicate Position
5.6
8.0
80
115
27
/
8” (73mm)
215
/
16” (75mm)
1,2,3,7
1,2,3,7
R3195 R3115
1/2” (15mm) Standard Orifice with ½” NPT (R½) Thread
17
/
32” (20mm) Large Orifice with ¾” NPT (R¾) Thread R3197 R3117
NOTE: The protective shield must be assembled in the field per the assembly drawings.
Upright Pendent
Upright Pendent Small Orifice UprightConventional
3.
Model GFR Quick Response Horizontal Sidewall Sprinkler
Deflector: HSW1
Installation Wrench: Model W2 Sprinkler Wrench
Installation Data:
Nominal
Orifice Thread Size
Nominal K
Factor Sprinkler
Height
Approval Organization
and Type of Approval Sprinkler
Identification
Number (SIN)
US Metric Light
Hazard
Ordinary
Hazard
1/2” (15mm)
7/16” (11mm)
3/8” (10mm)
17/32” (20mm)
½” NPT (R½)
½” NPT (R½)
½” NPT (R½)
¾” NPT (R¾)
5.6
4.2
2.8
8.0
80
60
41
119
35
/
16” (84mm)
35
/
16” (84mm)
35
/
16” (84mm)
35
/
16” (84mm)
1,2,3,7
1,2,3,7
1,2,3,7
1,2,3,7
1,2,3,7
—
—
—
R3135
R3133
R3131
R3137
Model GFR Quick Response Recessed Pendent Sprinklers
Installation Wrench: New Model GFR2 (F1 Recessed); Old Model GFR2 (FP Recessed)
Installation Data:
Sprinkler Type Nominal K Factor Sprinkler Height Approvals(2) Sprinkler Identification
Number (SIN)
US Metric
½” (15mm) Standard Orifice with ½” NPT (R½) Thread
7
/
16” (11mm) Small Orifice with ½” NPT (R½) Thread
3
/
8” (10mm) Small Orifice with ½” NPT (R½) Thread
10mm Orifice XLH with R3
/
8Thread
17/32” (20mm) Large Orifice with ¾” NPT (R¾) Thread
5.6
4.2
2.8
4.2
8.0
80
60
40
60
115
27
/
8” (73mm)
27
/
8” (73mm)
27
/
8” (73mm)
(73mm)
215
/
16” (75mm)
1,2,3,7
1,2,3,7
1,2,3,7
—
1,2,3,7
R3115
R3113
R3111
R3114
R3117
(1) Refer to escutcheon data table for specific escutcheon approvals and dimensions.
Model GFR Quick Response Recessed Horizontal Sidewall Sprinklers
Deflector: HSW1
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data
Nominal
Orifice
Thread
Size
NPT
Nominal K
Factor Sprinkler
Height
Approval
Organization(2)
Type of Approval
Sprinkler
Identification
Number
(SIN)
US Metric Light
Hazard
Ordinary
Hazard
1/2” (15mm)
7/16” (11mm)
3/8” (10mm)
17/32”(20mm)
½”(R½)
½”(R½)
½”(R½)
¾”(R¾)
5.6
4.2
2.8
8.0
81.0
61.0
40.6
118.2
35
/
16” (84mm)
35
/
16” (84mm)
35
/
16” (84mm)
35
/
16” (84mm)
1,2,3,7
1,2,3,7
1,2,3,7
1,2,3,7
1,2,3,7
—
—
—
R3135
R3133
R3131
R3137
(1) Refer to escutcheon data table for specific escutcheon approvals and dimensions.
Recessed Pendent /F1 Recessed Pendent /FP
EG. Printed in U.S.A. 08/19 P/N 9999970024
Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years.
Model GFR & GFR Recessed Quick Response Sprinklers
Finishes(1)(2)
Standard Finishes
Sprinkler Escutcheon
Bronze
Chrome Plated
Polyester Coated(3)
Brass
Chrome Plated
Polyester Coated
Special Application Finishes
Sprinkler Escutcheon
Bright Brass
Black Plated
Satin Chrome
Bright Brass
Black Plated
Satin Chrome
(1) Other finishes and colors are available, consult factory for details
(2) All sprinklers 165°F (74°C) have black painted solder links and all
sprinklers 212°F (100°C) have white painted solder links.
(3) FM Approved for R3127 only.
Temperature Ratings
Classification
Sprinkler
Rating
Maximum Ambient
Temperature
°F °C °F °C
Ordinary 165 74 100 38
Intermediate 212 100 150 66
Escutcheon Data
Escutcheon
Model Approvals Adjustment
Face of Fitting To
Ceiling or Wall Di-
mension
F1
F2
FP(1)
1,2,3
1,2,3
1,2
¾” (19mm)
½” (13mm)
¾” (19mm)
3
/
16” - 15
/
16” (5mm-24mm)
3
/
16” - 11
/
16” (5mm-18mm)
3
/
16” - 15
/
16” (5mm-24mm)
(1) Approved for Pendent only.
Installation
Quick response sprinklers are intended for standard area cov-
erage and standard water densities as specified in NFPA-13.
Quick response sprinklers and standard response sprinklers
should not be intermixed.
The Model GFR Recessed Quick Response Sprinkler is to be
installed as shown. The Model F1 or F2 Escutcheons illustrated
are the only recessed escutcheons to be used with the Model
GFR Pendent or Horizontal Sidewall Sprinklers. The use of any
other recessed escutcheon will void all approvals as a quick
response sprinkler and negate all warranties.
When installing Model GFR Sprinklers, use the Model W2
Sprinkler Wrench and when installing Model GFR Recessed
Sprinklers and Pendent Intermediate Sprinklers use the Model
GFR2 Sprinkler Wrench. Any other type of wrench may cause
sprinkler damage.
Maintenance
The Models GFR and GFR Recessed Sprinklers should be
inspected and the sprinkler system maintained in accordance
with NFPA 25. Do not clean the sprinklers with soap and water,
ammonia or any other cleaning fluids. Remove any dust using
a soft brush or gentle vacuuming. Remove any sprinkler which
has been painted (other than factory applied) or damaged in
any way. A stock of spare sprinklers should be maintained to al-
low quick replacement of damaged or operated sprinklers. Pri-
or to installation, sprinklers should be maintained in the original
cartons and packaging until used. This minimizes the potential
for damage resulting in improper operation or non-operation.
Ordering Information:
Specify
1. Sprinkler model
2. Sprinkler type
3. Orifice size
4. Temperature rating
5. Sprinkler finish
6. Escutcheon type
7. Escutcheon finish (where applicable)
Note: When Recessed Model GFR/F1 or F2 are ordered, sprinkler and es-
cutcheon are packaged separately.
Sprinkler Types
Standard Upright
Standard Pendent
Sidewall
— Horizontal HSW1 Deflector
Conventional
Recessed
— Pendent
— Horizontal Sidewall HSW 1 Deflector
Intermediate Level
— Upright
— Pendent

This manual suits for next models

20

Other Reliable Irrigation System manuals

Reliable HL22 User manual

Reliable

Reliable HL22 User manual

Reliable F1-300 User manual

Reliable

Reliable F1-300 User manual

Reliable G VELO Pendent Manual

Reliable

Reliable G VELO Pendent Manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable G5 Series User manual

Reliable

Reliable G5 Series User manual

Reliable F1-56-300 Series User manual

Reliable

Reliable F1-56-300 Series User manual

Reliable JL-14 Manual

Reliable

Reliable JL-14 Manual

Reliable SWC Manual

Reliable

Reliable SWC Manual

Reliable G5-56 300 User manual

Reliable

Reliable G5-56 300 User manual

Reliable KFR-CCS User manual

Reliable

Reliable KFR-CCS User manual

Reliable F3QR80 Dry Pendent Operator's manual

Reliable

Reliable F3QR80 Dry Pendent Operator's manual

Reliable N25 User manual

Reliable

Reliable N25 User manual

Reliable F156-300 Series Manual

Reliable

Reliable F156-300 Series Manual

Reliable G4A-300 User manual

Reliable

Reliable G4A-300 User manual

Reliable RFS42 User guide

Reliable

Reliable RFS42 User guide

Reliable G Series Manual

Reliable

Reliable G Series Manual

Reliable F1FR80 Series User manual

Reliable

Reliable F1FR80 Series User manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable F1FR80 Series User manual

Reliable

Reliable F1FR80 Series User manual

Reliable J168 User manual

Reliable

Reliable J168 User manual

Reliable DH56 HSW-PL User manual

Reliable

Reliable DH56 HSW-PL User manual

Reliable XL Commercial User manual

Reliable

Reliable XL Commercial User manual

Popular Irrigation System manuals by other brands

Tyco ESFR-25 General description

Tyco

Tyco ESFR-25 General description

Tyco Fire Product CENTRAL B instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL B instruction manual

Tyco Fire Product Star Pulsar S160QR instruction manual

Tyco Fire Product

Tyco Fire Product Star Pulsar S160QR instruction manual

Tyco Fire Product Gem F892QR instruction manual

Tyco Fire Product

Tyco Fire Product Gem F892QR instruction manual

Viking MICROFAST VK311 Technical data

Viking

Viking MICROFAST VK311 Technical data

Tyco TY7158 quick start guide

Tyco

Tyco TY7158 quick start guide

claber AQUAUNO MIST user manual

claber

claber AQUAUNO MIST user manual

TrimmerPlus LD720 Operator's manual

TrimmerPlus

TrimmerPlus LD720 Operator's manual

Tyco RapidResponse SIN TY4334 Operation

Tyco

Tyco RapidResponse SIN TY4334 Operation

Autopot easy2grow 16 Set-up guidelines

Autopot

Autopot easy2grow 16 Set-up guidelines

Nodolini S60 Installation, use and maintenance manual

Nodolini

Nodolini S60 Installation, use and maintenance manual

Viking VK506 Technical bulletin

Viking

Viking VK506 Technical bulletin

Autopot 36Pot system Set-up guidelines

Autopot

Autopot 36Pot system Set-up guidelines

Tyco F08 FIP Operator's manual

Tyco

Tyco F08 FIP Operator's manual

Tyco Fire Product Star Celeste S140 instruction manual

Tyco Fire Product

Tyco Fire Product Star Celeste S140 instruction manual

Toro TruJectory FLEX800 Series manual

Toro

Toro TruJectory FLEX800 Series manual

Hunter I-20 ULTRA manual

Hunter

Hunter I-20 ULTRA manual

Weathermatic D50 Series installation guide

Weathermatic

Weathermatic D50 Series installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.