4
REMKO ELT 10-HT
The units are portable electric
heating units for industrial
applications at various locations.
The units are operated exclusively
with electric power and have been
designed for high-temperature
applications with an air outlet
temperature of up to 120°C.
The air outlet temperature is
altered by manually adjusting the
fan speed.
The units can be operated using no
more than one high-temperature
hose (accessory) with a ø of
205 mm and a length of 7.6 m.
The units are equipped with
special-purpose, highly efficient
electrical heating coils for
immediate and consistent heat
generation, low-maintenance axial
fans, a safety thermostat, a room
thermostat socket and a mains
cable with earthed safety plug.
The units conform to the
fundamental health and safety
requirements of the appropriate
EU stipulations.
The units are dependable and offer
ease of operation.
The units may be used among
other things for the following:
■
Drying heat-resistant materials
■
Generating process heat for
industrial applications
■
Hardening plastics
■
Pest control
■
Drying out construction work/
heating
Safety notesUnit description
The units have been subjected
to extensive material, functional
and quality inspections prior to
delivery. However, dangers can
arise from the units if they are used
improperly or not as intended by
untrained personnel!
Please observe the following notes:
■
In the event of defects that
endanger the operational safety
of the unit, operation must be
discontinued immediately
■
Observe the respective local
electrical regulations and the
necessary safety measures when
using the units
■
Maintain safety distances to
combustible materials
0.5 m at the side of the unit and
on the air inlet side
2.0 m on the air outlet side
■
An unobstructed air inlet and air
outlet must be guaranteed at all
times
■
The units must not be covered
during operation
■
Never insert foreign objects into
the units
■
The units must not be operated
in the vicinity of bathtubs,
showers, swimming pools etc.
■
The units must not be operated
directly below a wall socket
■
The units may not be exposed to
direct jets of water
CAUTION
Extensions to the connection
cable must only be conducted
by authorised specialist
electricians, taking into
consideration the unit capacity,
cable length and local use.
■
The units must not be installed or
operated in potentially flammable
or explosive environments
■
The units must not be operated
in locations where:
Combustible gaseous, air or
dust-air mixtures could be
produced; flammable small parts
could be sucked in, set alight on
the heating coil and blown out
in a glowing state
■
Flooring and ceilings must be
fire retardant
■
The air inlet and outlet must not
be constricted
■
The relevant safety guidelines
of the Employer's Liability
Insurance Association or
property insurer must be
observed
■
The units must be installed
in a stable position and must
not topple over or slide out of
position during operation
■
The units must not be left
unattended during operation
■
The units must not be operated
in an environment with an
ambient temperature of over
60°C
■
All electrical cables for the
units must be protected against
damage, even damage caused
by animals