WIRELESS FLOOD DETECTOR
«STZ-RK»ver. 1
1 Product Overview
1.1 Wireless flood detector «STZ-RK» ver. 1 (hereinafter, the
Detector) is intended for detecting leaks of water from water-supply
pipelines or heating facilities and generating an alarm message
via a two-way communication by the «Rielta-Contact-R» protocol.
The Detector is intended to operate as a component of any control
panel (hereinafter, CP) supporting the wireless exchange protocol
«Rielta-Contact-R».
1.2 Water leaks control is ensured by measurement of an external
resistance between sensor terminals of the Detector.
1.3 Radio signals are exchanged within the 433.05 to 434.79 MHz
frequency range. The transmitter output power does not exceed
10 mW.
1.4 Two operating frequencies: main and reserve are used for the
wireless data exchange. The Detector switches over reserve operating
frequency automatically.
1.5 Radio exchange sessions are initiated by the Detector at a
preset frequency. The frequency settings are
10, 15, 30 sec,
1, 5,
10 min, chosen in the process of the binding procedure. The Detector
transmits alarm messages to the CP immediately.
1.6 The Detector power supply is provided by power supply batteries
placed inside it’s case: the main one and the backup one (CR2450).
1.7 The Detector state is displayed by two-color LED indicator.
1.8 The Detector generates and transmits the following messages
via a two-way communication:
- «Norm» – if the external resistance between sensor terminals value
is 200 kΩor more;
- «Alarm» – if the external resistance between sensor terminals
value is 100 kΩor less;
- «Tamper» – in the event of case tampering or the Detector removal
from the mounting surface;
- «Main Power Supply Low Battery» – under the main power supply
battery voltage drop below 2.8-0.4 V;
- «Backup Power Supply Low Battery» – under the backup power
supply battery voltage drop below 2.8-0.4 V.
1.9 The Detector is designed to operate continuously, around the
clock.
2 Features
Table 1
Parameter Value
Operating temperature, °C
minus 20 … +50
Permissible relative humidity at +25 °С without
moisture condensation up to, % 95
Ambient class Boreal Climate *
IP rating IP65
Dimensions, maximum, mm 65 x 55 x 20
Weight, maximum, kg 0,05
Average service life, not less, years 8
Operation time upon normal climate conditions* and
preset wireless signal exchange rate 30 sec and
more, months:
- from the main battery, not less:
- from the reserve battery, not less:
36
2
* background temperature 15 – 35 °C, relative air humidity
25 – 75%, air pressure 86 – 106 kPa.
3 Scope of Delivery
Each Detector unit package contains the items listed in Table 2.
Table 2
Name
QNT.
Wireless flood detector «STZ-RK» ver. 1
Screw 3-3х30.016
CR2450 lithium power supply battery
Wireless flood detector «STZ-RK» ver. 1. Installation Guide
1 pc.
1 pc.
2 pcs.
1 copy
4 The Detector Design
The Detector comprises the base with the openable mounting
hole (7) printed circuit board (1) (PCB) installed on the cover. The PCB
comprises the following elements: main power supply battery holder
plate (2), «RESET» contacts (3), backup power supply battery holder
plate (4), sensor terminals (5), tamper contacts (6).
Figure 1 – The Detector Design
5 Indication
The Detector has the following indication modes:
- «Binding» procedure LED indication (procedure of logging in the CP);
- «Identification»indication mode –lights up by the relevant command
from CP and remains active during 15 min or until the case is opened;
- LED indication of the Detector state is activated after the Detector
cover is closed and remains active during 15 min under conditions:
- other LED indication types absence;
- alarm «Tamper» message is not generated during this time;
- absence of command from the CP disabling the Detector state
indication.
LED indicator modes are listed in the Table 3.
Table 3
The Detector State LED Indication Note
Binding procedure
finished
LED lighting red for
2 – 3 sec
«
Binding
»
mode LED blinking green The Detector logging in
the CP
«
Identification
»
Alternate LED red and
green alternate blinking
on command from the
CP
«
Alarm
»
Single-shot LED lights up
red for 4 sec
State indication is on
and
«
Identification
»
indication is off
Radio communication
quality appraising See sect.
«
Radio communication quality appraising
»
«Normal»
Indication is off
6 Binding with the CP
«Binding»mode is used for logging the Detector in the CP and service
information exchange.
6.1 Prepare the CP in accordance with CP reference guide.
6.2 Initially install the backup power supply battery to the holder
plate (4) on the PCB, thereupon install the main power supply battery
to the holder plate (2).
6.3 Periodical LED indicator blinking green is evidence of binding
process.
6.4 In case of mentioned above LED indication absence, short-circuit
«RESET» terminals for 2 – 3 sec.
6.5 The time limit for the binding process of the Detector is 100 sec.
To restart the binding procedure, short-circuit «RESET» terminals for
2 – 3 sec.
7 Communication Quality Appraising
7.1 To apprise the radio communication quality it is necessary to
act as follows:
- place initially backup and then main power supply batteries to the
correspondent holder plates;
- set the Detector on the assumed place of installation;
- push and then release case tamper.
7.2 After case tamper releasing the Detector generates case
tamper alarm message, transmits it via radio communication channel
and represents communication quality with CP by LED indication in
accordance with the Table 4.
Table 4
LED Indication Radio
communication
quality appraisal
Recommendations
Color Mode
Green Three blinks Excellent Install the Detector on this
place
Green Two blinks Good
Green One blink Communication
established Choose another place
for installation or use a
repeater*)
Red
Four blinks
No
communication
*) – «Ladoga BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR», ver. 1
Installation Guide
а) Base b) PCB installed on the cover
1
7
2
3
4
6
5
5
RESET
the main
the backup
Rev 0 of 17.11.15
№00177
Made in Russia
10 Manufacturer’s Guarantees
10.1 «RIELTA» JSC guarantees conformity of the Detector to the
requirements of technical conditions provided the transportation,
storage, installation and operation conditions are observed.
10.2 The guaranteed shelf life of the Detector is 39 months since
the date of manufacture.
10.3 The guaranteed useful life is 36 months since the day of putting
into operation.
10.4 The Detectors that are found non-conforming to the requirements
of technical conditions shall be repaired by the manufacturer, provided
the installation and operation rules have been complied.
Note – Warranty obligations are not applied to power supply battery.
11 Acceptance and Packing Certificate
Wireless flood detector «STZ-RK» ver. 1,
batch number ____________________,
has been manufactured in compliance with the active technical
documentation and classified as fit for operation and packed by
«RIELTA» JSC.
Person responsible for acceptance and packing
QC representative_________________ __________________.
Date, month, year
«RIELTA» JSC, www.rielta.ru,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected].
8 Installation
8.1 Install the Detector in the place, where communication quality is
apprised as «good» or «Excellent» (See Table 4).
8.2 Fasten the base to the mounting surface by means of double-sided
mounting tape. To ensure the Detector secure mounting act as follows:
- make sure, that the mounting surface is flat, dry and clean;
- remove protective film from the mounting tape working surface;
- press the Detector tightly to the mounting surface and hold it for
2 – 3 sec;
For the wall-tamper monitoring, the second screw should be fastened
in an openable hole (7).
8.3 Install the cover with PCB on the base.
Attention! If the CP is planned to be switched off for a long time,
de-energize the Detector to ensure the battery resource economy.
9 Storage and Transportation
9.1 The Detector in original package without power supply batteries
is resistant to:
а) transport jolting with the acceleration of 30 m/sec2with impact
frequency rate from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
b) the ambient temperature from minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient temperature +35 °С.
9.2 The Detectors in original package may be transported by any
transport facility in closed vehicles over any distances in compliance with
the existing shipping rules concerning the respective means of transport.
9.3 After transportation under the conditions different to exploitation
conditions, the Detector shall be ready to operate after a maximum of
six hours.

Other Rielta Security Sensor manuals

Rielta PYRONE-SH2-RK User manual

Rielta

Rielta PYRONE-SH2-RK User manual

Rielta FOTON-17 User manual

Rielta

Rielta FOTON-17 User manual

Rielta GRAN-RK User manual

Rielta

Rielta GRAN-RK User manual

Rielta FOTON-16A User manual

Rielta

Rielta FOTON-16A User manual

Rielta Pyrone-7 User manual

Rielta

Rielta Pyrone-7 User manual

Rielta FOTON-10M User manual

Rielta

Rielta FOTON-10M User manual

Rielta Ladoga IPR-RK User manual

Rielta

Rielta Ladoga IPR-RK User manual

Rielta PYRONE-5 User manual

Rielta

Rielta PYRONE-5 User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta Ochrana ORLAN-D User manual

Rielta

Rielta Ochrana ORLAN-D User manual

Rielta Pyrone-7i User manual

Rielta

Rielta Pyrone-7i User manual

Rielta PYRONE-8-RK User manual

Rielta

Rielta PYRONE-8-RK User manual

Rielta PYRONE-4i User manual

Rielta

Rielta PYRONE-4i User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta ORLAN-2 User manual

Rielta

Rielta ORLAN-2 User manual

Rielta Pyrone-4RK User manual

Rielta

Rielta Pyrone-4RK User manual

Rielta FOTON-SH User manual

Rielta

Rielta FOTON-SH User manual

Rielta chrana ORLAN-SH User manual

Rielta

Rielta chrana ORLAN-SH User manual

Rielta FOTON-SH2-RK User manual

Rielta

Rielta FOTON-SH2-RK User manual

Rielta STEKLO-2 User manual

Rielta

Rielta STEKLO-2 User manual

Rielta C.Nord CN-Glass User manual

Rielta

Rielta C.Nord CN-Glass User manual

Rielta C.Nord CN-Flood-Mini User manual

Rielta

Rielta C.Nord CN-Flood-Mini User manual

Rielta FOTON-SH2-RK User manual

Rielta

Rielta FOTON-SH2-RK User manual

Popular Security Sensor manuals by other brands

lap 9695V instructions

lap

lap 9695V instructions

Visonic DISCOVERY QUAD MCW installation instructions

Visonic

Visonic DISCOVERY QUAD MCW installation instructions

SkylinkHome ID-318 manual

SkylinkHome

SkylinkHome ID-318 manual

CPS Leak-Seeker 1 Operation manual

CPS

CPS Leak-Seeker 1 Operation manual

Roger G90/F4ES manual

Roger

Roger G90/F4ES manual

SKF Lincoln 254-15165-9 Service manual

SKF

SKF Lincoln 254-15165-9 Service manual

Ultra-safe US-96760-120 User instruction manual

Ultra-safe

Ultra-safe US-96760-120 User instruction manual

Bentel Security FC450IB manual

Bentel Security

Bentel Security FC450IB manual

Linxon LX218 operating manual

Linxon

Linxon LX218 operating manual

SENTRONIC VS133-P user guide

SENTRONIC

SENTRONIC VS133-P user guide

Potter IDC-6 installation manual

Potter

Potter IDC-6 installation manual

Omron E9NC-TH Series instruction sheet

Omron

Omron E9NC-TH Series instruction sheet

Air Specialties Express LU-BELT Installation, operating and maintenance instructions

Air Specialties Express

Air Specialties Express LU-BELT Installation, operating and maintenance instructions

Satel AVD-100 manual

Satel

Satel AVD-100 manual

KeCheng KC-098 Operation manual

KeCheng

KeCheng KC-098 Operation manual

Lena Lighting WSED414 HIM14 manual

Lena Lighting

Lena Lighting WSED414 HIM14 manual

Teletek electronics SensoIRIS GAS manual

Teletek electronics

Teletek electronics SensoIRIS GAS manual

Numens HNC-310 installation instructions

Numens

Numens HNC-310 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.