Introduction and Features
The BWare BUS DT detector is a motion detector designed for
installation as an addressable detector on the RISCO BUS,
incorporating Anti Cloak™ Technologies (ACT™).
•MW K Band and PIR technologies
•Anti Cloak Technology (ACT™)
•Green Line™ for disabling the MW during disarm
•Cover tamper
•Corridor and Curtain lenses (optional)
•Remote Control & Diagnostics
•15m (90') coverage
Introduction et caractéristiques
Le détecteur BWare BUS DT est un détecteur de mouvement destiné à
être installé en tant que détecteur adressable sur le BUS RISCO,
incorporant les technologies Anti Cloak™ (ACT™).
•Technologies hyperfréquence Bande K et IR Passif
•Technologie Anti Cloak™ (ACT™)
•Green Line™ pour désactiver l’hyperfréquence durant le
désarmement
•Sabotage contre l'ouverture
•Lentilles couloir et rideau (optionnelles)
•Contrôle et diagnostique à distance
•Couverture 15m (90')
Introduzione e caratteristiche
BWare BUS DT è un rivelatore di movimento a doppia tecnologia
indirizzato compatibile con il BUS RISCO che include tecnologia Anti
Cloak™ (ACT™).
• Tecnologia a microonde (MW in banda K) e infrarosso
passivo (PIR)
• Tecnologia Anti Cloak (ACT™)
• Funzione “Green Line” per disabilitare le emissioni della
sezione microonda a sistema disinserito
• Tamper contro l’apertura
• Lenti a Tenda e Corridoio (opzionali)
• Diagnostica e Controllo Remoto
• Modelli da 15m (90')
Introducción y características
El detector BWare BUS DT es un detector de movimiento diseñado
para su instalación como detector direccionable en el BUS de RISCO,
que incorpora las tecnologías de Anti Cloak™ (ACT™).
•Doble tecnología MW (Banda K) y PIR
•Tecnología Anti Cloak (ACT™) para detectar intrusos camuflados
•GreenLine™ para deshabilitar el MW cuando el sistema
esté desarmado
•Sabotaje contra la apertura
•Lentes de Pasillo y Cortina (opcionales)
•Control y Diagnósticos Remotos
•Cobertura 15m (90')
Introdução e características
O BWare BUS, detector de dupla tecnologia, é um detector de
movimento projetado para ser instalado como detector endereçável
ao RISCO Bus, incorporando tecnologia quanto Anti Cloak ™.
• Tecnologia Anti Camuflagem (ACT ™)
• Tecnologia GreenLine Desativa MW (Microondas),quando o
sistema é desativado
• Sabotagem contra a abertura
• Lentes de longo alcance e Cortina (opcional)
• Controle e diagnóstico remoto
• Modelo 15m (90')
64mm (2.51")
120mm (4.72")
44mm (1.73")
9-16VDC
100gr. (3.5oz.)
mA
12mA at 12VDC (typical)
34mA at 12VDC (max.)
-20° to 55°C ( -4° to 131°F)
Humidity of 85 ±5 percent at a
temperature of 30 ±2°C (86 ±4°F).
BUS
COM
RED BLK YEL
+ 12 -
GRN Z1
LONG
15m (50’)
SHORT
6m (20’)
LONG
SHORT
RISCO BUS
12VDC
MIN MAX
N/C N/O 4.7K
N/C N/O EOL
NO
TEOL
N/C Tamper Switch
N/C Alarm Relay
4.7K
6.8K
12K
DEOL
4.7K
6.8K
N/C Tamper
Switch
N/C Alarm Relay
12
4
5
3
ID 1 2 3 4 5
01 OFF OFF OFF OFF OFF
02 ON OFF OFF OFF OFF
03 OFF ON OFF OFF OFF
04 ON ON OFF OFF OFF
05 OFF OFF ON OFF OFF
06 ON OFF ON OFF OFF
07 OFF ON ON OFF OFF
08 ON ON ON OFF OFF
09 OFF OFF OFF ON OFF
10 ON OFF OFF ON OFF
11 OFF ON OFF ON OFF
12 ON ON OFF ON OFF
13 OFF OFF ON ON OFF
14 ON OFF ON ON OFF
15 OFF ON ON ON OFF
16 ON ON ON ON OFF
17 OFF OFF OFF OFF ON
18 ON OFF OFF OFF ON
19 OFF ON OFF OFF ON
20 ON ON OFF OFF ON
21 OFF OFF ON OFF ON
22 ON OFF ON OFF ON
23 OFF ON ON OFF ON
24 ON ON ON OFF ON
25 OFF OFF OFF ON ON
26 ON OFF OFF ON ON
27 OFF ON OFF ON ON
28 ON ON OFF ON ON
29 OFF OFF ON ON ON
30 ON OFF ON ON ON
31 OFF ON ON ON ON
32 ON ON ON ON ON
O
N
12345
BUS ADDRESS
2.1m-2.7m
(6'11"-8'10")
N/C FAULT/ AM Contact
3RL0025H (Corridor)
Walk Test Test Sensore Prueba de detección Test de Marche Prova de Moviento
EN FRIT PRES
© RISCO Group 04/2015 5IN2111 C
United Kingdom
Tel: +44-161-655-5500
support-uk@r scogroup.com
Spain
Tel: +34-91-490-2133
support-es@r scogroup.com
Belgium (Benelux)
Tel: +32-2522-7622
support-be@r scogroup.com
Contacting RISCO Group
RISCO Group s comm tted to customer serv ce and product support. You can contact us through our
webs te www.r scogroup.com or as follows:
China (Shanghai)
Tel: +86-21-52-39-0066
support-cn@r scogroup.com
Italy
Tel: +39-02-66590054
support- t@r scogroup.com
France
Tel: +33-164-73-28-50
support-fr@r scogroup.com
US
Tel: +1-631-719-4400
support-usa@r scogroup.com
ustralia
Tel: + 1-800-991-542
support-au@r scogroup.com
Israel
Tel: +972-3963-7777
support@r scogroup.com
= ON
CD
A B = 2 Min
2 Min. (Max)
7
RISCO Group Limited Warranty
RISCO Ltd., ts subs d ar es and aff l ates (the "Seller") warrants ts products to be free from defects n mater als
and workmansh p under normal use for 24 months from the date of product on.
Because the Seller does not nstall or connect the product, and because the product may be used n conjunct on
w th products not manufactured by the Seller, the Seller cannot guarantee the performance of the secur ty
system wh ch uses th s product.
The Seller's obl gat on and l ab l ty under th s warranty s expressly l m ted to repa r ng and replac ng, at the
Seller's d scret on, w th n a reasonable t me after the date of del very, any product not meet ng these
spec f cat ons.
The Seller makes no other warranty, expressed or mpl ed, and makes no warranty of merchantab l ty or of
f tness for any part cular purpose.
Under no c rcumstances should the Seller be l able for any consequent al or nc dental damages for breach of
th s or any other warranty, expressed or mpl ed, or upon any other bas s of l ab l ty whatsoever.
The Seller's obl gat on under th s warranty shall not nclude any transportat on charges or costs of nstallat on or
any l ab l ty for d rect, nd rect, or consequent al damages or delay.
The Seller does not warrant that the product may not be comprom sed or c rcumvented; that the product w ll
prevent any personal njury or property loss by burglary, robbery, f re or otherw se; or that the product w ll n all
cases prov de adequate warn ng or protect on.
The buyer/customer understands that a correctly nstalled and ma nta ned alarm may only reduce the r sk of
burglary, robbery or f re w thout warn ng, but s not an nsurance or a guarantee that such an event w ll not
occur or that there w ll be no personal njury or property loss as a result thereof.
Consequently the Seller shall have no l ab l ty for any personal njury, property damage or loss based on a cla m
that the product fa ls to g ve warn ng.
However, f the Seller s held l able, whether d rectly or nd rectly, for any loss or damage ar s ng under th s
l m ted warranty or otherw se, regardless of cause or or g n, the Seller's max mum l ab l ty shall not exceed the
purchase pr ce of the product, wh ch shall be a complete and exclus ve remedy for the Seller.
No employee or representat ve of the Seller s author zed to change th s warranty n any way or grant any other
warranty.
Batter es nstalled n or used w th the products are expl c tly excluded from th s or any other warranty. Seller
g ves no warranty whatsoever as to batter es and buyer's only remedy ( f any) shall be n accordance w th the
warranty prov ded ( f and to the extent prov ded) by the manufacturers of batter es.
RTTE Compliance Statement:
Hereby, RISCO Group declares that th s equ pment s n compl ance w th the essent al requ rements and other
relevant prov s ons of D rect ve 1999/5/EC. For the CE Declarat on of Conform ty please refer to our webs te:
www.r scogroup.com.
Yellow
LED
LED Display
State
On
Description
PIR Detect on
Flash ng Trouble n PIR channel
Green On MW Detect on
Flash ng Trouble n MW channel
Blue On Alarm
Flash ng Commun cat on Trouble
ll
LEDs
Flash ng
(consecutively)
At power-up, the LEDs w ll flash consecut vely
unt l the end of the warm-up per od (2-3
m nutes). At the end of the warm-up per od the
BLUE LED w ll cont nue to flash unt l the end of
AM cal brat on.
EN
Amarillo
LED
Indicación de los LEDs
Estado
Encendido
Descripción
Detección PIR
Parpadeando Problema en el canal PIR
Verde Encendido Detección MW
Parpadeando Problema en el canal MW
Azul Encendido Indicación de ALARMA
Parpadeando Problema de comunicación
Todos
los
LEDs
Parpadeando
(consecutivamente)
Al dar alimentación, los LEDs parpadearán
consecutivamente hasta que finalice el
periodo de calentamiento (2-3 minutos). Al
finalizar el periodo de calentamiento, el LED
AZUL seguirá parpadeando hasta que termine
la calibración del AM.
ES
Giallo
LED
Indicatori LED
Stato
Illum nato
Descrizione
Rilevazione del canale all’infrarosso passivo (PIR)
Lampegg ante Anomal a del canale PIR
Verde Illum nato Rilevazione del canale a microonda (MW)
Lampegg ante Anomal a del canale MW
Blu Illum nato ALLARME
Lampegg ante Problema d comun caz one
Tutti i
LED
Lampeggiante
(consecutivamente)
All’al mentaz one tutt LED lampegg ano n
sequenza f no alla f ne del per odo d
prer scaldamento (2-3 m nut ). Alla f ne del
per odo d prer scaldamento l LED BLU
cont nuerà a lampegg are f no alla f ne della
fase d n z al zzaz one del canale Ant -Mask.
IT
Jaune
LED
ffichage LED
Etat
Allumée
Description
Détect on IRP
Cl gnotante Défaut canal IRP
Verte Allumée Détect on HF
Cl gnotante Défaut canal HF
Bleu Allumée Alarme
Cl gnotante Défaut de commun cat on
Totalité
LED’s
Cl gnotante
(consécutivement)
Au démarrage, les voyants LED cl gnotent
success vement jusqu'à la f n de la pér ode
d'échauffement (2-3 m nutes). A la f n de la
pér ode d'échauffement la LED bleue
cont nuera à cl gnoter jusqu'à la f n de
l'étalonnage AM.
FR
marelo
LED
Visualizacão dos LEDs
Estado
Aceso
Descricao
Detecção de Infravelmenho Pass vo
P scado Problema no canal Infravelmenho Pass vo
Verde Aceso Detecção no M croondas
P scado Problema no canal M croondas
zul Aceso ALARME
P scado Problema de comun cação
Todos os
LEDs
P scado
(sucess vamante)
Ao conectar, os LEDs p scarão
consecut vamente até o f nal do período de
aquec mento (2-3m nutos). Ao f nal do
período de aquec mento, o LED AZUL
cont nuará p scando até o f nal da n c ação
do AM.
PR
RL0004H (Wide Angle)
Wide Angle – Side View
Wide Angle – Top View
Corridor – Side View
Corridor – Top View
3RL0024H (Curtain)
Curtain – Top View
Curtain – Side View
Corridor – Side View
FCC modular approval
Contains FCC ID UXS-IPM165F BWare RK515DTG3 FCC Compliance Section:
FCC Part 15 Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician.
FCC Warning:
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
Such modifications could void the user's authority to operate the equipment.
MW Sensitivity Portata Microonda
Alcance del Microondas
Sensibilité MW Alcance de microondas
EN
FR
IT
PR
ES
System Programming:
1. Add/delete a BWare BUS detector
• Installer menu [7] Accessories / Install > [1] Add Delete Module > [9] More.. > [ ] BUS Zone.
• Select ID (as defined by the Dip switches) and define type as BDTG2.
2. Assign the BWare BUS detector to a Zone
• Installer menu [2] Zones > [1] One by One > Select Zone.
• Under Termination select > [ ] BUS Zone.
• Select the BUS zone number to assign to the programmed zone.
3. Program the zone input on the BWare BUS
• Installer menu [2] Zones > [1] One by One > Select Zone.
• Under Termination select from options [07] to [11].
• Press [#]. Select the BUS zone that the input zone belongs to.
4. Configure the BWare BUS detector parameters.
• Installer menu select [2] Zones > [0] Miscellaneous > [3] BUS Zone Parameters. Refer to System Installation Manual.
Programmazione Sistema:
ProSYS: 1. Aggiungi/cancella un rivelatore BUS BWare
• Menù Tecnico [7] Accessori > [1] Agg./Canc.Modulo > [9] Continua.. > [ ] Zone BUS
• Selezionare il numero ID (come impostato dai microinterrutori) e definire il tipo come BDTG2
2. Assegnazione del rivelatore BUS BWare ad una Zona
• Menù Tecnico [2] Zone > [1] Una per Una > Selezionare il numero di zona
• Raggiunta l'opzione Terminazione selezionare > [ ] Zona BUS
• Selezionare il numero ID della zona BUS da assegnare alla zona che si sta programmando
3. Programmazione dell'ingresso di zona aggiuntivo sul rivelatore BUS BWare
• Menù Tecnico [2] Zone > [1] Una per Una > Selezionare il numero di zona
• Raggiunta l'opzione Terminazione selezionare una delle opzioni da [07] a [11]
• Premere [#]. Selezionare il numero ID della zona BUS che fa riferimento all'ingresso di zona che si sta programmando
4. Configurazione dei parametri del rivelatore BUS Bware
• Nel Menù Tecnico selezionare [2] Zone > [0] Varie > [3] Parametri Zone BUS > Selezionare il numero di zona al
quale è stato assegnato il rivelatore. Fare riferimento al Manuale Tecnico della centrale per i parametri del rivelatore
LightSYS: 1. Aggiungi/cancella un rivelatore BUS Bware
• Menù Tecnico [7] Configurazione > [1] Accessori BUS > [2] Configurazione Manuale > [9] Zone-BUS
• Selezionare l’identificativo ID (come impostato dai microinterruttori) e definire il Tipo come BDTG2
3. Programmare l’ingresso di zona del rivelatore BWare BUS
• Una volta completata l’operazione descritta al punto 1, la centrale automaticamente chiederà se aggiungere alla
zona sucessiva l’ingresso di zona aggiuntivo del rivelatore
4. Programmare i parametri del rivelatore
• Menù Tecnico [2] Zone > [1] Parametri > [2] Per Parametro > [7] Avanzati > [4] Zone BUS > Selezionare il numero di
zona al quale è stato assegnato il rivelatore. Fare riferimento al Manuale Tecnico della centrale per i parametri del
rivelatore
Programación Sistema:
1. Añadir/Borrar un detector BWare BUS
• Menú Instalador > [7] Accesorios > [1] Agregar/Borrar Módulo > [9] Más... > [ ] Zonas BUS
• Seleccione el ID (según se haya definido con los microinterruptores DIP) y defina el tipo como BDTG2
2. Asignar el detector BWare BUS a una Zona
• Menú Instalador > [2] Zonas > [1] Una a Una > Seleccione la Zona
• En el apartado Terminación, seleccione la opción [0 ] Zona BUS.
• Seleccione el ID del detector BUS que se va a asignar a la zona programada.
3. Programar la entrada de zona adicional del BWare BUS
• Menú Instalador > [2] Zonas > [1] Una a Una > Seleccione la Zona.
• En el apartado Terminación, seleccione una de las opciones de la [07] a la [11].
• Presione [#]. Seleccione el ID del detector BUS al que pertenece la entrada de zona.
4. Configuración de los parámetros del detector BWare BUS.
• Menú Instalador > [2] Zonas > [0] Varios > [3] Parámetros Zona BUS. Consulte el manual de instalación del sistema
para la configuración de los parámetros del detector BUS.
PR
Programmation Système:
1. Ajout/Supp détecteur BWare BUS
• Menu Installateur [7] Accessoires / Installation > [1] Ajout/Supp Module > [9] Plus. > [ ] Zone BUS.
• Sélectionner l’ID (défini par les Dip switches) et définir le type en BDTG2
2. Assigner le détecteur BWare BUS à une Zone
• Menu Installateur [2] Zones > [1] Une par Une > Sélectionner Zone.
• Dans Nature sélectionner > [ ] BUS Zone.
• Sélectionner le numéro de la zone BUS à assigner à la zone programmée.
3. Programmer la zone d’entrée du BWare BUS
• Menu Installateur [2] Zones > [1] Une par Une > Sélectionner Zone.
• Dans Nature sélectionner les options [07] à [11].
• Appuyer sur [#].Sélectionner le numéro de la zone BUS à assigner à la zone programmée.
4. Configurer les paramètres du détecteur BWare BUS.
• Menu Installateur sélectionner [2] Zones > [0] Divers > [3] Param Zone BUS. Reportez-vous au manuel d'installation
du système pour les paramètres des détecteurs BUS.
Programação da Sistema:
1. Adicionar/Apagar um detector BWare BUS
• Menu do instalador [7] Acessórios > [1] Adicionar/Apagar módulo > [9] Mais.. > [ ] Zonas de BUS.
• Selecionar ID (como definido nos Dipswitches) e definir como o tipo BDTG2
2. Alocar o BWare BUS à uma zona
• Menu do Instalador [2] Zonas > [1] Uma a Uma > Selecionar Zona.
• No menu de Terminação selecione > [ ] Zona de BUS.
• Selecione o número da zona de BUS para alocar a zona programada.
3. Programação da entrada de zona do BWare BUS
• Menu do instalador [2] Zonas > [1] Uma a uma > Selecionar Zona.
• No menu de terminação escolha uma das opções de [07] até [11].
• Apertar [#]. Escolher a zona de BUS que a entrada de zona pertence.
4. Configurar os parâmetros do detector BWare BUS.
• Selecionar o menu do instalador [2] Zonas > [0] Diversos > [3] Parâmetros de Zonas de BUS.
6
FR
ES
IT
EN

This manual suits for next models

1

Other Risco Security Sensor manuals

Risco Industrial LuNAR RK200DTG3 User manual

Risco

Risco Industrial LuNAR RK200DTG3 User manual

Risco EL-5835D User manual

Risco

Risco EL-5835D User manual

Risco WL X312 User manual

Risco

Risco WL X312 User manual

Risco Lumin8 4012 User manual

Risco

Risco Lumin8 4012 User manual

Risco WiComm Pro Instruction manual

Risco

Risco WiComm Pro Instruction manual

Risco Wireless WatchOUT PIR 868 User manual

Risco

Risco Wireless WatchOUT PIR 868 User manual

Risco RK66S User manual

Risco

Risco RK66S User manual

Risco Wireless VITRON RWT6G User manual

Risco

Risco Wireless VITRON RWT6G User manual

Risco WatchIN 325DT User manual

Risco

Risco WatchIN 325DT User manual

Risco WatchOUT User manual

Risco

Risco WatchOUT User manual

Risco iWISE QUAD AM Grade 3 User manual

Risco

Risco iWISE QUAD AM Grade 3 User manual

Risco iREX User manual

Risco

Risco iREX User manual

Risco ViTRON RWT6G User manual

Risco

Risco ViTRON RWT6G User manual

Risco LuNAR PR RK2000DPC User manual

Risco

Risco LuNAR PR RK2000DPC User manual

Risco WatchOUT XTreme 315DT User manual

Risco

Risco WatchOUT XTreme 315DT User manual

Risco iWave RWX95 User manual

Risco

Risco iWave RWX95 User manual

Risco PIR 4150200A User manual

Risco

Risco PIR 4150200A User manual

Risco RWT6FW43300A User manual

Risco

Risco RWT6FW43300A User manual

Risco Bware K-Band DT AM User manual

Risco

Risco Bware K-Band DT AM User manual

Risco ShockTec Plus Grade 3 User manual

Risco

Risco ShockTec Plus Grade 3 User manual

Risco DigiSense Digi-412DTPT User manual

Risco

Risco DigiSense Digi-412DTPT User manual

Risco WatchU User manual

Risco

Risco WatchU User manual

Risco iWISE RWT92043300C User manual

Risco

Risco iWISE RWT92043300C User manual

Risco iWISE QUAD AM Grade 3 User manual

Risco

Risco iWISE QUAD AM Grade 3 User manual

Popular Security Sensor manuals by other brands

Visonic SPY 1 installation instructions

Visonic

Visonic SPY 1 installation instructions

Niko Swiss Garde 360 Presence DALI Secondary... installation instructions

Niko

Niko Swiss Garde 360 Presence DALI Secondary... installation instructions

LIMIT VD 101 operating manual

LIMIT

LIMIT VD 101 operating manual

HTS ECO-JackDUAL HT600 user manual

HTS

HTS ECO-JackDUAL HT600 user manual

DMP Electronics 1126 Series Installation sheet

DMP Electronics

DMP Electronics 1126 Series Installation sheet

Electronics Line EL-2800 installation instructions

Electronics Line

Electronics Line EL-2800 installation instructions

GLD D-TECT 3 quick start guide

GLD

GLD D-TECT 3 quick start guide

Illumra E9T-OSH installation guide

Illumra

Illumra E9T-OSH installation guide

Bosch RADION contact SM installation guide

Bosch

Bosch RADION contact SM installation guide

Axis F1004 installation guide

Axis

Axis F1004 installation guide

Global Fire Equipment ZEOS-AD manual

Global Fire Equipment

Global Fire Equipment ZEOS-AD manual

ASE PM-2B Instructions for installing

ASE

ASE PM-2B Instructions for installing

Sofamel D-TUERI DUAL 648 manual

Sofamel

Sofamel D-TUERI DUAL 648 manual

York 2SD04700124 installation instructions

York

York 2SD04700124 installation instructions

Hytronik HIR21 quick start guide

Hytronik

Hytronik HIR21 quick start guide

Potter CS-24 Series manual

Potter

Potter CS-24 Series manual

Genesis LG2 WP-3020 Installation handbook

Genesis

Genesis LG2 WP-3020 Installation handbook

Bosch Photobeam 3000 ISC-FPB1-W30DS installation guide

Bosch

Bosch Photobeam 3000 ISC-FPB1-W30DS installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.