5
The hole diameter shall be close to that of the exhaust pipe. Undersized hole will cause poor exhaust efficiency,
more noises and lower airflow. The connection between the pipe and the hole or the public flue must be sealed tightly
to ensure that, the pipe and the check valve or public flue is connected securely. The blades at the check valve
connection or public flue connection must be flexible.
Figure 4
Hood body
Check valve
Check valve connection
ST4 x 18 screw
Check valve seals
Note: During installation, straighten the aluminum exhaust pipe to avoid noises
in semi-stretched state. Excess part may be cut with a wire cutter.
Snap
Slot
●The drilling size of aluminum exhaust pipe(No need to drill hole for the public flue)
a).Aluminum exhaust pipe and hob facing the window: To remove one of the glasses and install a plywood with ventilation
holes or punch directly on the glass.
b).Hob away from the window: To install the aluminum exhaust pipe through the window that is close to the hob and connected
outside, or install it by punching on the wall that is close to the hob and connected outside.
c).Drill hole through the wall: Determine the location of the aluminum exhaust pipe against the wall and draw the drilling
range (i.e a circle slightly larger than the pipe OD).Use a long drill bit to drill through the wall. Pay attention to the wall structure
and material, so as not to destroy other parts of the wall.
Insert the other pipe end to the pipe connection and stick with tapes. Straighten the aluminum exhaust pipe to the
outdoors.This can be done directly when the wall hole is larger than the pipe.Otherwise, there are four pipe
ends(OD:140,150,160,and 170 respectively) to be chosen from according to the hole size.Then cut the excess part with
scissors.
Then, insert one of the ends in the outer ring of the check valve connection and seal with exhaust pipe tapes. Finally, put four
snaps of the check valve connection in corresponding slots, and rotate them clockwise to fix the exhaust pipe to the check valve.
●Connect aluminum exhaust pipe
Φaluminum exhaust pi pe175
Exhaust pipe tape Φex haust p ipe connection175
Cut the excess p art sma ller than the hole
Φ180
Φ170
Φ160
Φ150
Φ140
Exhaust pipe tape
Install the aluminum exhaust pipe:
Figure 5
●
●
●
As shown in Figure1-1, there are some gap between the drawing panel and the top plate. Push the panel against the top plate and then
fix it to the top plate with ST4x18 screws.(If installation method in Figure1-2, there’s no need to adjust and install the drawing panel).
Note: If there is no drawing panel, no need to adjust or install it.
Adjust the drawing panel:
Pull the brackets of the panel up to an appropriate height and then pull the panel sides to find the drawing panel. Remove the protective film,
and insert it along the gap between the decorative panel and the housing. Then adjust it to the proper height.
Install the hood body: fix the check valve as shown in Figure 5. Then direct the hanging holes in the back of hood at the hooks of hitching
foots according to Figure 2, and press them together. Shake the body to check if it's hung securely. After the body is mounted, install the
hitching foot stopper and gaskets to the M6 metal expansion pipe, and then tighten the nuts ( to prevent accidental decoupling of the body
under external force).
Install the drawing panel:
Range Hood