MCT84M-BK-QB Installation Manual.doc 2022-05-17
1/2
Roger Access Control System
MCT84-BK-QB Installation Manual
Firmware version: 1.0.8.209 and newer
Document version: Rev. A
This document contains minimum information that is necessary for initial setup
and installation of the device. The detailed description of configuration
parameters and functionalities is specified in respective Operating Manual
available at www.roger.pl.
INTRODUCTION
The reader is designed for operation with MC16 access controller (RACS 5
system). Factory new reader is configured with default settings including ID=100
address.
DEVICE CONFIGURATION
The reader can be configured in regard of various parameters (including
address) in order to adapt it to the requirements of specific installation. Device
can be configured from VISO v2 management software or RogerVDM utility
software.
Note: Remote configuration of device from VISO v2 software is possible only if
jumper is placed on MEM contacts (fig. 2). If the jumper is removed then such
configuration is blocked. In case of factory new device, jumper is placed on MEM
contacts.
CONFIGURATION WITH VISO V2PROGRAM
In RACS 5 v2 system the reader can be installed at site without previous
configuration. According to AN006 application note, its address and other
settings can be configured from VISO v2 management software and during such
configuration the access to its service contacts (fig. 2) is not required.
CONFIGURATION WITH ROGERVDM PROGRAM
Fig. 1 Connection of MCT terminal to RUD-1 interface
Programming procedure:
1. Connect the device to RUD-1 interface (fig. 1) and connect the RUD-1 to
computer’s USB port.
2. Remove jumper from MEM contacts (fig. 2) if it is placed there.
3. Restart the device (switch power supply off and on) and orange LED
SYSTEM will pulsate. Then within 5 seconds place jumper on MEM contacts.
4. Start RogerVDM program, select MCT device, firmware version, RS485
communication channel and serial port with RUD-1 interface.
5. Click Connect, the program will establish connection and will automatically
display Configuration tab.
6. Enter unoccupied RS485 address in range of 100-115 and other settings
according to requirements of specific installation.
7. Click Send to Device to update the configuration of device.
8. Optionally make a backup by clicking Send to File… and saving settings to
file on disk.
9. Disconnect from RUD-1 interface and leave jumper on MEM contacts to
enable further configuration of device from VISO v2 software or remove
jumper from MEM contacts to block such remote configuration.
Note: Do not read any cards when reader is configured with RogerVDM.
MANUAL ADDRESSING
Manual addressing procedure enables configuration of new RS485 address with
all other settings unchanged.
Manual addressing procedure:
1. Remove all connections from A and B lines.
2. Remove jumper from MEM contacts (fig. 2) if it is placed there.
3. Restart the device (switch power supply off and on) and orange LED
SYSTEM will pulsate. Then within 5 seconds place jumper on MEM contacts.
4. Enter 3 digits of RS485 address in range of 100-115 with any MIFARE card.
5. Leave jumper on MEM contacts to enable further configuration of device from
VISO v2 software or remove jumper from MEM contacts to block such remote
configuration.
6. Restart the device.
Terminals without keypad can be addressed with multiple card readings where
the N number of readings emulates digit of the address. Three series of readings
with any MIFARE proximity card are necessary to set the address. After each
series wait for two beeps and proceed with the next digit. Zero digit is emulated
with 10 readings.
Example:
Programming of ID=101 address with card readings:
1. Read card 1 time and wait for two beeps.
2. Read card 10 times and wait for two beeps.
3. Read card 1 time and wait for two beeps.
4. Wait till reader is restarted with the new address.
MEMORY RESET
Memory reset procedure resets all settings to factory default ones including
ID=100 address.
Memory reset procedure:
1. Remove all connections from A and B lines.
2. Remove jumper from MEM contacts (fig. 2) if it is placed there.
3. Restart the device (switch power supply off and on) and orange LED
SYSTEM will pulsate. Then within 5 seconds place jumper on MEM contacts.
4. Read any MIFARE card 11 times.
5. Wait till device confirms reset with long acoustic signal.
6. Leave jumper on MEM contacts to enable further configuration of device from
VISO v2 software or remove jumper from MEM contacts to block such remote
configuration.
7. Restart the device.
FIRMWARE UPDATE
The firmware of device can be changed to newer or older version. The update
requires connection to computer with RUD-1 interface (fig. 1) and starting
RogerVDM software. The latest firmware file is available at www.roger.pl.
Note: Backup configuration with RogerVDM software before firmware update
because the update will restore factory default settings.
Firmware update procedure:
1. Connect the device to RUD-1 interface (fig. 1) and connect the RUD-1 to
computer’s USB port.
2. Place jumper on MEM contacts (fig. 2).
3. Restart the device (switch power supply off and on).
4. Start RogerVDM program and in the top menu select Tools and then Update
firmware.
5. In the opened window select device type, serial port with RUD-1 interface
and path to firmware file (*.frg).
6. Click Update to start firmware upload with progress bar in the bottom.
7. When the update is finished, disconnect from RUD-1 interface and remove
jumper from MEM contacts. Additionally it is recommended to start memory
reset procedure.
APPENDIX
Fig. 2 Enclosure opening and location of service contact
MCT84M-BK-QB Installation Manual.doc 2022-05-17
2/2
Table 1. Wires
Name
Wire colour
Description
12V
Red
Supply plus
GND
Black
Ground
A
Yellow
RS485 bus, line A
B
Green
RS485 bus, line B
Table 2. Specification
Supply voltage
Nominal 12VDC, min./max. range 10-15VDC
Current consumption
(average)
~80 mA (additional 120mA if barcode scanner is
configured for continuous operation)
Tamper protection
Enclosure opening reported to access controller
Identification methods
13.56MHz MIFARE Ultralight, Classic, Plus and
Desfire proximity cards
Mobile devices (Android, iOS) with NFC
Mobile devices (Android, iOS) with BLE (Bluetooth
Low Energy) v4.1
1D barcodes: UPC A, UPC E, EAN 8, Interleaved
2 of 5, EAN 13, GS1-128, Code 128;
2D barcodes: QR, PDF417, Data Matrix
Reading range
Up to 7 cm for MIFARE cards and NFC
Up to 10 m for BLE –depends on ambient
conditions and particular mobile device. Terminal’s
radio power can be increased within low level
configuration.
Distance
1200 m maximal cable length for RS485 bus
between controller and terminal
IP Code
IP65
Environmental class
(according to EN 50133-1)
Class IV, outdoor general conditions, temperature:
-25°C to +60°C, relative humidity: 10 to 95% (no
condensation)
Dimensions H x W x D
130 x 45 x 22 mm
Weight
~100g
Certificates
CE
Fig. 3 Connection of terminals and expanders to MC16 access controller
This symbol placed on a product or packaging indicates that the
product should not be disposed of with other wastes as this may
have a negative impact on the environment and health. The user is
obliged to deliver equipment to the designated collection points of
electric and electronic waste. For detailed information on recycling,
contact your local authorities, waste disposal company or point of
purchase. Separate collection and recycling of this type of waste
contributes to the protection of the natural resources and is safe to
health and the environment. Weight of the equipment is specified in
the document.
Contact:
Roger Sp. z o. o. sp. k.
82-400 Sztum
Gościszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: support@roger.pl
Web: www.roger.pl

Other Roger IP Access Controllers manuals

Roger PR302 User manual

Roger

Roger PR302 User manual

Roger PR311 Installation guide

Roger

Roger PR311 Installation guide

Roger MC16-SVC User manual

Roger

Roger MC16-SVC User manual

Roger OSR88M-IO User manual

Roger

Roger OSR88M-IO User manual

Roger CEB12 User manual

Roger

Roger CEB12 User manual

Roger MC16-PAC-3-KIT User manual

Roger

Roger MC16-PAC-3-KIT User manual

Roger EDGE1 Series Product manual

Roger

Roger EDGE1 Series Product manual

Roger MC16 User manual

Roger

Roger MC16 User manual

Roger PRT12MF-DES User manual

Roger

Roger PRT12MF-DES User manual

Roger PR402DR User manual

Roger

Roger PR402DR User manual

Roger LRT-1 User manual

Roger

Roger LRT-1 User manual

Roger MCT80M-BLE User manual

Roger

Roger MCT80M-BLE User manual

Roger RFT1000 Use and care manual

Roger

Roger RFT1000 Use and care manual

Roger PR612 User manual

Roger

Roger PR612 User manual

Roger PR302 User guide

Roger

Roger PR302 User guide

Roger PR411DR-SET User manual

Roger

Roger PR411DR-SET User manual

Roger PR201 Assembly instructions

Roger

Roger PR201 Assembly instructions

Roger ME-14-24V User manual

Roger

Roger ME-14-24V User manual

Roger PR602LCD-DT-I User manual

Roger

Roger PR602LCD-DT-I User manual

Roger MC16-PAC-16 User manual

Roger

Roger MC16-PAC-16 User manual

Roger MCT12M User manual

Roger

Roger MCT12M User manual

Roger MCT68ME-IO-I User manual

Roger

Roger MCT68ME-IO-I User manual

Roger QUADRUS SERIES User manual

Roger

Roger QUADRUS SERIES User manual

Roger MCT12E User manual

Roger

Roger MCT12E User manual

Popular IP Access Controllers manuals by other brands

Progeny Chameleon manual

Progeny

Progeny Chameleon manual

Holars AS H-TAG user manual

Holars AS

Holars AS H-TAG user manual

Techsphere VP-II M installation guide

Techsphere

Techsphere VP-II M installation guide

Sebury sTouch2 instruction manual

Sebury

Sebury sTouch2 instruction manual

Timewatch UltraFP804 Series quick start guide

Timewatch

Timewatch UltraFP804 Series quick start guide

Stanley PAC iPAC quick start guide

Stanley

Stanley PAC iPAC quick start guide

Akuvox A092 Series Administrator's guide

Akuvox

Akuvox A092 Series Administrator's guide

SECO-LARM ENFORCER Wireless RF Request-to-Exit Buttons... manual

SECO-LARM

SECO-LARM ENFORCER Wireless RF Request-to-Exit Buttons... manual

Aiphone AC-10U Installation & operation manual

Aiphone

Aiphone AC-10U Installation & operation manual

TECOM ChallengerPlus Installation and Quick Programming Manual

TECOM

TECOM ChallengerPlus Installation and Quick Programming Manual

CDVI DGLIEWLC installation manual

CDVI

CDVI DGLIEWLC installation manual

ENFORCER SK-1131-SPQ manual

ENFORCER

ENFORCER SK-1131-SPQ manual

Schlage Panel Interface Module RS485 Installation & operating instructions

Schlage

Schlage Panel Interface Module RS485 Installation & operating instructions

EverFocus ERR-871 Specifications

EverFocus

EverFocus ERR-871 Specifications

GeoVision GV-CS1320 quick start guide

GeoVision

GeoVision GV-CS1320 quick start guide

Prosonic PRO-698 instruction manual

Prosonic

Prosonic PRO-698 instruction manual

Entrya EntraHOME quick start guide

Entrya

Entrya EntraHOME quick start guide

H3C LSUM1WCME0 manual

H3C

H3C LSUM1WCME0 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.