The AXD-200 detector is designed for operation within the ABAX 2 / ABAX two-way wireless
system. It is a multipurpose device that can be used as magnetic contact, shock,
reorientation, temperature or flood detector. You should select the type of detector before
adding it to the system (see “Selecting detector type”). Table 1shows how the detector is
identified in the wireless system, depending on the selected type.
Detector name in the system
ABAX 2 ABAX Detector type
AMD-200 AMD-100 Magnetic contact
AMD-201 AMD-101 Dual channel magnetic contact
AMD-202 AMD-102 Magnetic contact with input for roller shutter
detector
AVD-200 AVD-100 Shock detector and magnetic contact
ARD-200 ARD-100 Reorientation detector
ATD-200 ATD-100 Temperature detector
AFD-200 AFD-100 Water flood detector
Table 1.
The detector with factory default settings is identified in the ABAX 2 system as AMD-200, and
in the ABAX system as AMD-100.
This manual applies to the detector with firmware version 1.00, which is supported by:
ABAX 2:
– ACU-220 / ACU-280 controller,
– ARU-200 repeater.
ABAX:
– ACU-120 / ACU-270 controller (firmware version 5.04 or newer),
– ARU-100 repeater (firmware version 2.02 or newer),
– INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware
version of processor used to operate ABAX system 3.10 or newer).
The temperature detector (ATD-200) is not supported by the controller connected to
the VERSA / VERSA Plus / VERSA IP control panel.
1 Features
Possibility to select the type of detector before adding it to the system.
Encrypted two-way radio communication in the 868 MHz frequency band (AES standard
for the ABAX 2 system).
Transmission channel diversity – 4 channels for automatic selection of the one that will
enable transmission without interference with other signals in the 868 MHz frequency
band (ABAX 2 system only).
Remote update of detector firmware (ABAX 2 system only).
Remote configuration.
Built-in temperature sensor (temperature measurement range from -10°C to +55°C).