IMPORTANT
The device should be installed by qualified personnel.
Prior to installation, please read carefully this manual.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
The rating plate of the device is located on the enclosure base.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us at:
http://www.satel.eu
Hereby, SATEL sp. z o.o. declares that the radio equipment type AXD-200 is in
compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.satel.eu/ce
The following symbols may be used in this manual:
- note,
- caution.

The AXD-200 detector is designed for operation within the ABAX 2 / ABAX two-way wireless
system. It is a multipurpose device that can be used as magnetic contact, shock,
reorientation, temperature or flood detector. You should select the type of detector before
adding it to the system (see “Selecting detector type”). Table 1shows how the detector is
identified in the wireless system, depending on the selected type.
Detector name in the system
ABAX 2 ABAX Detector type
AMD-200 AMD-100 Magnetic contact
AMD-201 AMD-101 Dual channel magnetic contact
AMD-202 AMD-102 Magnetic contact with input for roller shutter
detector
AVD-200 AVD-100 Shock detector and magnetic contact
ARD-200 ARD-100 Reorientation detector
ATD-200 ATD-100 Temperature detector
AFD-200 AFD-100 Water flood detector
Table 1.
The detector with factory default settings is identified in the ABAX 2 system as AMD-200, and
in the ABAX system as AMD-100.
This manual applies to the detector with firmware version 1.00, which is supported by:
ABAX 2:
– ACU-220 / ACU-280 controller,
– ARU-200 repeater.
ABAX:
– ACU-120 / ACU-270 controller (firmware version 5.04 or newer),
– ARU-100 repeater (firmware version 2.02 or newer),
– INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware
version of processor used to operate ABAX system 3.10 or newer).
The temperature detector (ATD-200) is not supported by the controller connected to
the VERSA / VERSA Plus / VERSA IP control panel.
1 Features
Possibility to select the type of detector before adding it to the system.
Encrypted two-way radio communication in the 868 MHz frequency band (AES standard
for the ABAX 2 system).
Transmission channel diversity – 4 channels for automatic selection of the one that will
enable transmission without interference with other signals in the 868 MHz frequency
band (ABAX 2 system only).
Remote update of detector firmware (ABAX 2 system only).
Remote configuration.
Built-in temperature sensor (temperature measurement range from -10°C to +55°C).

2 AXD-200 SATEL
“ECO” option for longer battery life (ABAX 2 system only).
Battery status control.
LED indicator.
Tamper protection against enclosure opening and removal from mounting surface.
2 magnets included (for surface and flush mounting).
AMD-200
Magnetic contact
Detects open door, window, etc.
Input for connecting an NC type wired detector.
Occupies 1 position on the device list.
In the ABAX system, the detector is identified as AMD-100.
AMD-201
Dual channel magnetic contact
Detects open door, window, etc.
Input for connecting an NC type wired detector.
Additional digital channel for a wired detector.
Occupies 2 positions on the device list (optionally 1 – only the additional NC input is
supported).
In the ABAX system, the detector is identified as AMD-101.
AMD-202
Magnetic contact with input for roller shutter detector
Detects open door, window, etc.
Input for connecting a wired roller shutter detector.
Input for connecting an NC type wired detector.
Occupies 2 positions on the device list (optionally 1 – only the additional inputs [roller
shutter and NC] are supported).
In the ABAX system, the detector is identified as AMD-102.
AVD-200
Shock detector and magnetic contact
Detects shocks and vibrations accompanying attempts to force open a door or window.
Detects open door, window, etc.
Occupies 2 positions on the device list (optionally 1 – only the shock detector is
supported).
In the ABAX system, the detector is identified as AVD-100.
ARD-200
Reorientation detector
Detects changes in the position of protected object.
Occupies 1 position on the device list.
In the ABAX system, the detector is identified as ARD-100.

SATEL AXD-200 3
ATD-200
Temperature detector
Detects exceeding of the predefined temperature threshold.
Two programmable temperature thresholds.
Occupies 2 positions on the device list (optionally 1 – you can program just one
temperature threshold).
In the ABAX system, the detector is identified as ATD-100.
AFD-200
Water flood detector
Detects flooding in spaces provided with water installation.
Occupies 1 position on the device list.
In the ABAX system, the detector is identified as AFD-100.
The water flood detector requires you to purchase the FPX-1 probe, offered by
SATEL.
2 Description
Radio communication
The detector connects to the controller / control panel at regular time intervals to provide
information about its state (periodical communication). Additional communication may take
place as a result of alarm (see “Operating modes”).
Alarms
Described below are circumstances in which the detector reports alarm, depending on the
detector type. Irrespective of the detector type, tamper alarm is reported on opening the
tamper contact.
AMD-200 / AMD-201
The detector will report alarm:
after moving the magnet away from the detector (opening the window or door),
after opening the NC type input.
AMD-202
The detector will report alarm:
after moving the magnet away from the detector (opening the window or door),
after opening the NC type input,
after registering the specified number of pulses within a defined time period by the roller
shutter input,
after opening the roller shutter input (tamper alarm).
AVD-200
The detector will report alarm:
after detecting a shock caused by impact,
after moving the magnet away from the detector (opening the window or door).

4 AXD-200 SATEL
ARD-200
The detector reports alarm when it senses a change in its position. The detector remembers
position at the moment of being switched into active mode or starting the test mode. Fig. 1
shows the changes in orientation that can be sensed by the detector.
ATD-200
The detector reports alarm when it registers a temperature higher / lower than the predefined
threshold. The detector allows you to program two critical temperature thresholds: low (L)
and high (H). The detector will alert of the threshold being exceeded if the temperature:
drops below the value preprogrammed for the low (L) threshold,
rises above the value preprogrammed for the high (H) threshold.
Information about the current temperature is sent when the detector connects to the
controller / control panel.
AFD-200
The detector reports alarm approximately 5 seconds after the water level reaches the height
at which the probe is installed. The detector reports end of flooding a few seconds after the
water level drops below the height at which the probe is installed.
Operating modes
Active – information about each alarm is sent immediately.
Passive – only information about tamper alarm is sent immediately. This operating mode
prolongs the battery life.
The detector operating mode is turned on remotely. If the detector is used in the INTEGRA /
VERSA alarm system, the operating mode may depend on the partition state (partition
disarmed – passive mode; partition armed – active mode). For more information, refer to the
ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL control panel manual.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable in the detector the “ECO” option. When
the “ECO” option is enabled, the periodical communication takes place every 3 minutes. Thus
the battery life can be increased as much as fourfold. The option is only available in the
ABAX 2 system. The detector with “ECO” option enabled meets requirements of the
EN50131-2-6 standard for Grade 2.

SATEL AXD-200 5
Test mode
The test mode makes the detector testing easier, because the LED indicator is enabled. How
to start and end the test mode is described in the ABAX 2 / ABAX controller manual / the
INTEGRA 128-WRL control panel manual.
LED
The LED is flashing rapidly for about 10 seconds after the battery is inserted to indicate that
the process of selecting the detector type can be initiated (see “Selecting detector type”).
The LED also works in the test mode, in which it indicates:
periodical communication – short flash (80 milliseconds),
alarm – ON for 2 seconds.
Battery status control
When the battery voltage is below 2.75 V, information about low battery is sent during each
transmission.
Electronics board
Do not remove the electronics board from the enclosure to
avoid damage to the components on the board.
Fig. 2 shows the detector inside after opening the enclosure.
terminal block:
COM - common ground.
M1 - input supported in the case of the AMD-200, AMD-201,
AMD-202 and AFD-200 detectors. It allows connection of
an NC type detector (AMD-200 / AMD-201 / AMD-202) or
the flood probe (AFD-200).
M2 - input supported in the case of the AMD-202 detector. It
allows connection of the roller shutter detector.
To make the connection, use wires with a cross-section of 0.5-
0.75 mm2. If no detector or flood probe is connected to the input,
the terminal must be connected to common ground.
tamper contact.
CR123A lithium battery.
3 Installation
There is a danger of battery explosion when using a different battery than
recommended by the manufacturer, or handling the battery improperly.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.

6 AXD-200 SATEL
The detector is designed for indoor installation. Installing the detector in close vicinity of
electrical systems is not recommended, since it can adversely affect the range of radio
signal.
Mount the detector on fixed surface. In the case of magnetic contacts (AMD-200 / AMD-201 /
AMD-202 / AVD-200), mount the detector on the window / door frame (fixed surface), and the
magnet on the window / door (moving surface). Mounting the magnetic contact on
ferromagnetic surfaces and/or near to strong magnetic and electrical fields is not advisable,
because it can result in malfunctioning of the device.
If the detector is to be installed on the window frame, select the upper part of the frame
for this purpose. This will reduce the probability of the detector being flooded
accidentally, when the window is partially or full open.
The following tools will be useful to mount the detector:
blade screwdriver 1.8 mm,
Phillips screwdriver,
precision pliers,
drill with a set of drill bits.
1. Open the detector enclosure (Fig. 3). The enclosure opening tool, shown in the
illustration, is included in the detector delivery set.
2. Install the battery and select the detector type (see “Selecting detector type”).
3. Add the detector to the wireless system (see the ABAX 2 / ABAX controller manual or the
INTEGRA 128-WRL control panel installer manual). The sticker with serial number which
shall be entered when registering the detector in the system can be found on the
electronics board.
In the INTEGRA / VERSA alarm system the detector is identified the same as in the
ABAX system (cf. table 1).

SATEL AXD-200 7
Simultaneous operation of the detector by the ABAX 2 and ABAX controller /
INTEGRA 128-WRL alarm control panel is not possible.
4. Close the detector enclosure.
5. Put the detector at the place of its future installation.
6. Check the level of signal received from the detector by the ABAX 2 / ABAX controller or
the INTEGRA 128-WRL control panel. If the signal level is lower than 40%, select another
place for installation. Sometimes, it is sufficient to shift the device ten or twenty
centimeters to obtain a considerable improvement in the signal quality. You can also try to
turn the enclosure to check what effect the change of antenna position will have on the
signal strength.
The ARF-200 tester makes it possible to check the radio signal strength at the place of
future installation without having to put the detector there.
For the shock detector (AVD-200), check also the detector range in the selected
location of installation.
7. Open the detector enclosure (Fig. 3).
8. If detectors or flood probe are to be connected to the additional input terminals, make
a hole in the enclosure base, run wires through the hole and secure them to the terminals.
9. Use wall plugs (anchors) and screws to secure the enclosure base to the mounting
surface (Fig. 4). The wall plugs delivered with the device are intended for concrete, brick,
etc. For other types of surface (drywall, styrofoam), use the appropriately selected wall
plugs.
10.Close the detector enclosure.
11.In the case of the magnetic contact (AMD-200 / AMD-201 / AMD-202 / AVD-200), secure
the magnet (Fig. 5). taking into account the maximum permissible distance from the
magnetic sensor (Fig. 6). The distance shown applies to the magnet located at the sensor
height. Location of the sensor in the enclosure is shown in Fig. 7.
To make the hole for flush magnet, use the ø9 mm drill bit.
12. Configure the detector settings (see the ABAX 2 / ABAX controller manual / the
INTEGRA 128-WRL control panel manual).
13.Start the test mode (see the ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL
control panel manual).

8 AXD-200 SATEL

SATEL AXD-200 9
14.Depending on the detector type and configuration, make sure that the LED comes on:
AMD-200:
– after moving the magnet away (opening the window or door),
– after violating the detector connected to the additional input M1.
AMD-201:
– after moving the magnet away (opening the window or door),
– after violating the detector connected to the additional input M1.
AMD-202:
– after moving the magnet away (opening the window or door),
– after violating the detector connected to the additional input M1,
– after raising / lowering the roller shutters supervised by the roller shutter detector.
AVD-200:
– after moving the magnet away (opening the window or door),
– after impact against the surface protected by the detector.
The shock detector range depends on the type of surface on which the detector is
installed. The specified detection range (up to 3 m) should be considered an
approximate value. The actual range should be determined experimentally after
securing the detector to the surface.
ARD-200 – after changing the detector position.
AFD-200 – after submerging the flood probe in water.
15.For the water flood detector, when the test is done, secure the FPX-1 probe as shown in
Fig. 8.
3.1 Selecting detector type
1. Install the battery in the detector. The detector LED will start flashing rapidly.
2. Within 10 seconds of inserting the battery, knock 3 times on the detector enclosure. The
LED will flash to indicate the selected detector type – see Table 2.
Number of LED flashes Detector type
1 Magnetic contact (AMD-200)
2 Dual channel magnetic contact (AMD-201)
3 Magnetic contact with input for roller shutter detector
(AMD-202)
4 Shock detector and magnetic contact (AVD-200)
5 Reorientation detector (ARD-200)
6 Temperature detector (ATD-200)
7 Water flood detector (AFD-200)
Table 2.
If you do not want to change the detector type, wait for about 10 seconds. If there are
no impacts within 10 seconds, the detector type selecting procedure will be
terminated. The LED will indicate once more what type is saved in the detector
memory.

10 AXD-200 SATEL
3. Knock once on the detector enclosure to select next type as shown in Table 2. The next
type after the water flood detector (7 flashes) is the magnetic contact (1 flash).
4. Wait until the LED flashes once and then indicates the type that has been selected. You
can only select next type when the LED stops flashing.
5. Repeat the steps 3 and 4 until you select the appropriate type of detector.
6. Wait about 10 seconds. After that time the LED will inform you what type has been saved
to the detector memory.
Do not close the detector enclosure before saving the type to the detector memory.
Otherwise, it can be interpreted by the detector as another knock on the enclosure,
which will change the type selected.
4 Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 ..............................................................................................up to 2000 m
ACU-280 ..............................................................................................up to 1200 m
ABAX..............................................................................................................up to 500 m
Battery.................................................................................................................... CR123A 3 V
Battery life expectancy .......................................................................................... up to 2 years
NC type input sensitivity................................................................................................. 240 ms
Temperature measurement range .......................................................................-10°C...+55°C
Temperature measurement accuracy ................................................................................±1°C
Standby current consumption .......................................................................................... 20 µA
Maximum current consumption ......................................................................................... 7 mA
Complied with standards....... EN 50130-4, EN 50130-5, EN 50131-1, EN 50131-2-6, EN 50131-5-3
Security grade according to EN50131-2-6 ....................................................................Grade 2
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity ..........................................................................................................93±3%
Enclosure dimensions ................................................................................... 20 x 102 x 23 mm
Surface mounted magnet enclosure dimensions .............................................. 15 x 52 x 6 mm
Surface mounted magnet spacer dimensions ................................................... 15 x 52 x 6 mm
Flush mounted magnet enclosure dimensions...................................................... ø10 x 28 mm
Weight.................................................................................................................................59 g
Magnetic contact
Gap (max.):
surface magnet ..............................................................................................20 mm
flush magnet................................................................................................... 18 mm
Shock detector
Detection range (depending on the surface type) .......................................................up to 3 m
The specified detection range should be considered approximate. The actual range
should be determined experimentally after securing the detector to the surface.
This manual suits for next models
14
Table of contents
Other Satel Security Sensor manuals

Satel
Satel AGD-100-BR User manual

Satel
Satel OPAL Plus User manual

Satel
Satel GRAPHITE User manual

Satel
Satel COBALT Pro User manual

Satel
Satel AQUA PET User manual

Satel
Satel GREY User manual

Satel
Satel FD-1 User manual

Satel
Satel AQUA PLUS User manual

Satel
Satel INDIGO User manual

Satel
Satel micra MXD-300 User manual

Satel
Satel abax2 User manual

Satel
Satel OPAL Pro User manual

Satel
Satel MAGENTA User manual

Satel
Satel APMD-150 User manual

Satel
Satel SLIM-PIR-LUNA-PET User manual

Satel
Satel GRAPHITE User manual

Satel
Satel AQUA User manual

Satel
Satel AQUA LUNA User manual

Satel
Satel MAGENTA User manual

Satel
Satel AMD-101 User manual