4Manual – Fieldbus Interface DFS11B PROFIBUS DP-V1 with PROFIsafe®
6.6 PROFIBUS pin assignment.......................................................................... 31
6.6.1 Connecting MOVIDRIVE®/ MOVITRAC®B / PROFIBUS ............... 31
6.6.2 Baud rates greater than 1.5 MBaud .................................................. 31
6.7 Shielding and routing bus cables ................................................................. 32
6.8 Bus termination ............................................................................................ 32
6.9 Setting the station address .......................................................................... 33
6.10 Operation indicators of the DFS11B option.................................................. 34
6.10.1 PROFIBUS LEDs ............................................................................. 34
7 Project Planning and Startup.............................................................................. 36
7.1 Validity of the GSD files for DFS11B............................................................ 36
7.2 Project planning of PROFIBUS / PROFIsafe with MOVIDRIVE®GSD file.. 36
7.2.1 GSD file for PROFIBUS DP-V1 ........................................................ 36
7.2.2 Project planning procedure ............................................................... 37
7.2.3 DP configurations for MOVIDRIVE®MDX61B .................................. 38
7.3 Project planning for DP master with MOVITRAC®or gateway GSD file...... 41
7.3.1 GSD file for operation in MOVITRAC®B and UOH11B
gateway housing ............................................................................... 41
7.3.2 PROFIBUS DP master startup .......................................................... 42
7.3.3 Configuring the PROFIBUS DP interface ......................................... 43
7.3.4 Operating mode (DP-V1 mode) ........................................................ 46
7.3.5 Auto setup for gateway operation ..................................................... 47
7.4 Setting the MOVIDRIVE®MDX61B drive inverter ....................................... 49
7.5 Setting the MOVITRAC® B frequency inverter ............................................ 50
7.6 Project planning of PROFIsafe with STEP7................................................. 52
7.6.1 Hardware structure ........................................................................... 52
7.6.2 Installing the GSD file ....................................................................... 53
7.6.3 Configuring the DFS in HW Config ................................................... 54
7.6.4 Project planning for a new configuration ........................................... 55
7.6.5 Setting the parameters of the PROFIsafe properties ........................ 56
7.6.6 Description of the F-parameters ....................................................... 56
7.6.7 Safety diagnostics using PROFIBUS DP .......................................... 58
7.6.8 Response times of PROFIsafe option DFS ...................................... 60
7.7 Procedure for starting up DFS11B with MOVIDRIVE® MDX61B ................ 61
7.7.1 Preliminary work ............................................................................... 61
7.7.2 Switch on MOVIDRIVE® MDX61B with DC 24 V or AC 400 V ........ 62
7.8 Procedure for starting up DFS11B with MOVITRAC® B (gateway)............. 64
7.8.1 Preliminary work ............................................................................... 64
7.8.2 Switch on the units with DC 24 V or AC 400 V ................................. 64
8 PROFIBUS DP operating characteristics........................................................... 67
8.1 Data exchange with the DFS11B option ...................................................... 67
8.1.1 Mapping the DFS in the address range of the PLC .......................... 68
8.1.2 F periphery DB of PROFIsafe option DFS ........................................ 69
8.2 Controlling the MOVIDRIVE®MDX61B drive inverter ................................. 71
8.2.1 Control example for SIMATIC S7 with MOVIDRIVE®MDX61B ....... 72
8.2.2 PROFIBUS DP timeout (MOVIDRIVE®MDX61B) ............................ 72
8.2.3 Fieldbus timeout response (MOVIDRIVE®MDX61B) ....................... 72
8.3 Controlling the MOVITRAC®B inverter (gateway)....................................... 73
8.3.1 Control example for SIMATIC S7 with MOVITRAC®B (gateway) .... 74
8.3.2 SBus timeout .................................................................................... 74
8.3.3 Unit error ........................................................................................... 74
8.3.4 Fieldbus timeout of the DFS11B in gateway operation ..................... 75
8.4 SIMATIC S7 example program .................................................................... 75