Sharp IG-DC2A User manual

ENGLISH
IG-DC2A
Plasmacluster is a registered trademark or a
trademark of Sharp Corporation.
Plasmacluster 乃 Sharp 株式會社的註冊商標或
商標。
Plasmacluster Ion Generator
OPERATION MANUAL
Read and keep this manual carefully. *1 本技術標示的數字是指本商品向空中吹出的每 1cm3中所
含離子的數目。該數值是在房間中央位置 ( 離地 0.5 米 ),
而機器擺放在類似杯座的地方,運行高速風速時所量度的。
*1 The number on this technical mark indicates the number
of ion count per 1cm3blown out to the air, which is
measured near the center of space (0.5m height from
floor) when the air volume is "HIGH" by placing this
product at the place supposing a cup holder beside the
driver's seat.
SHARP CORPORATION
Osaka, Japan
Printed in Thailand
TINS-A569KKRZ 12E- 1
請仔細閱讀並妥善保存這本手冊。
HD PCI
抗菌機
使用說明書
中文
IG-DC2A.EN.indd1IG-DC2A.EN.indd1 2012/04/1110:54:032012/04/1110:54:03

IG-DC2A.EN.indd2IG-DC2A.EN.indd2 2012/04/1110:54:042012/04/1110:54:04

ENGLISH
ENGLISH
Thank you for purchasing this SHARP Plasmacluster Ion Generator.
Please read this manual carefully before using Plasmacluster Ion
Generator.
After reading, keep the manual in a convenient location for future
reference.
E-1
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ...............E-2
• WARNING ...............................................................E-2
• CAUTIONS CONCERNING OPERATION ......................E-3
PARTS NAME ........................................................E-4
• MAIN UNIT • CONTROL PANEL/DISPLAY.......................... E-4
• BACK/ACCESSORIES ........................................................E-4
INSTALLATION GUIDANCE ........................................ E-5
OPERATION ......................................................................E-7
CLEANING AND MAINTENANCE ............................. E-8
• FILTER ................................................................................. E-8
• MAIN UNIT...........................................................................E-8
• PLASMACLUSTER ION GENERATING UNIT .................... E-9
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
.. E-10
REPLACING THE FUSE..............................................E-12
SPECIFICATIONS.......................................................... E-12
TROUBLESHOOTING.................................................. E-13
• While IG-DC2A can remove suspended viruses and other
contaminants, it cannot create a completely sterile environment.
SHARP does not guarantee its ability to prevent microbial
infection.
• To enable stable emission of high-density Plasmacluster ions, the
Plasmacluster Ion Generating Unit mounted in IG-DC2A will need
to be replaced periodically*.
•
The unit is designed for ordinary passenger cars with DC 12V batteries.
It cannot be used in vehicles with DC 24V batteries (buses, trucks, etc.).
* Replacement is required approximately every 6 years (17,500 hours) when
operated 8 hours a day. IG-DC2A will stop operating after about 6 years
and 6 months (19,000 hours) if the Plasmacluster Ion Generating Unit is
not replaced.
IG-DC2A.EN.indd3IG-DC2A.EN.indd3 2012/04/1110:54:042012/04/1110:54:04

E-2
IMPORTANT SAFETY INSTRUCTIONS
Please read instructions carefully before using this unit as below.
WARNING - To reduce the risk of electric shock, fire or injury :
When using electrical appliances, basic safety precautions should be
followed, including the following:
• Do not operate switches while driving. (Doing so could lead to accidents.)
• Do not install the unit in places where it could hamper visibility to the front or driving
operations, or in places where it could be dangerous to passengers. (Doing so could lead
to accidents or injury.)
• Do not put in places exposed to direct sunlight. (Do so could cause warping or
malfunction.)
• This unit is designed exclusively for use in vehicles with 12V batteries. Do not use it
in other vehicles. Do not use the unit in large trucks, buses or other vehicles with 24V
batteries. (Doing so could lead to fire or electric shock.)
• Do not damage or modify the cord. Also, do not use the cord if it is damaged.
(The damaged section could cause short-circuiting and the cord could melt, leading to fire.)
If the cord is damaged, contact your store of purchase or SHARP authorized service
center.
• Do not pull on the cord when unplugging the cigar plug or the unit connection plug. (Doing
so could damage the cord, leading to fire or electric shock.)
• Do not plug in or unplug the cigar plug or the unit connection plug with wet hands. (Doing
so could cause electric shock.)
• When transporting, be careful not to drop the unit or subject it to shocks.
(Doing so could cause injury or damage.)
If the unit should drop or get damaged, contact your store of purchase or SHARP
authorized service center.
Continued usage as such could lead to fire or electric shock.
• Do not modify the unit. Also, no one other than an authorized repairman should take
apart or repair the unit. (Doing so could lead to fire, electric shock or injury.)
Contact your store of purchase or SHARP authorized service center for repairs.
• Do not spill beverages or drop cigarette ashes, metal objects, easily burnable objects,
etc., into the unit through the air outlet or air intake.
Be particularly careful if there are small children in your family. If water or foreign
substances should get inside the unit, unplug the cigar plug from the cigar lighter socket.
(Continued usage as such could lead to fire or electric shock.)
Contact your store of purchase or SHARP authorized service center.
• Do not wipe the unit with oils, alcohol, benzene or thinner, or spray hairspray or
insecticides on the unit.
If such substances should get on the unit, wipe them off immediately.
(Such substances could lead to cracking or electric shock or could catch fire.)
• Do not place the product at the place where is exposed to oil smoke or moisture such as
kitchen counter or humidifying device. (Doing so could lead to electric shock.)
• Do not place the product near heating equipment such as outlet of hot-air type heater. (Do
so could cause warping or malfunction.)
• Use the car adapter designed exclusively for this unit, and insert the cigar plug securely
all the way in until it stops.
(If the cigar plug is not inserted securely until it stops, it could heat up, deforming the
cigar lighter socket, and this could lead to fire.)
IG-DC2A.EN.indd4IG-DC2A.EN.indd4 2012/04/1110:54:042012/04/1110:54:04

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION:
• Do not touch the metal parts of the car adapter’s cigar plug (or of the cigar lighter
socket).
(The metal parts of the cigar plug could be hot directly after the car is stopped, and could
cause burns if touched.)
• Do not use the unit in commercially available cup holders, on shaky or non-level
surfaces or in other unstable places. (The unit could fall, resulting in injury or damage.)
• Move the unit out of the car when using room fumigating type insecticides or deodorizers.
If not, the chemicals could get inside the unit and later be ejected from the air outlet,
possibly harming your health.
• If the unit risks falling out of the cup holder (when driving on rough roads, over bumps,
etc.), either slow down or remove the unit from the cup holder beforehand.
(Failure to do so could cause injury or damage to the unit.)
• Do not use items of silicone-containing products* near the unit.
The fluororesin or silicone could get stuck inside the unit, preventing it from producing
plasmacluster ions.
If this happens, remove the dust from the electrode section of the Plasmacluster Ion
Generating Unit. (See E-9)
* Hair care products (split end coatings, hair mousses, hair treatments, etc.), cosmetics,
antiperspirants, antistatic agents, waterproofing sprays, polishes, glass cleaners, chemical-
impregnated clothes, wax, etc.
• If the fuse should blow, be sure to replace it with a 5A glass tube fuse (commercially
available). Never use a piece of wire, etc., in place of the fuse.
(Using anything other than the specified type of fuse could cause heating, leading to fire.)
• Be sure to unplug the cigar plug from the cigar lighter socket when cleaning. (Failure to
do so could cause electric shock or injury.)
• Be sure to unplug the cigar plug from the cigar lighter socket when not using the unit for
long periods of time. (Failure to do so could lead to electric shock or fire caused by short-
circuiting.)
• If the cigar lighter socket is integrated into the ashtray, be sure that cigarettes are
completely put out before using.
When leaving the vehicle, unplug the cigar plug and close the ashtray’s lid.
(Failure to do so could lead to fire caused by the smoldering cigarettes.)
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
IG-DC2A.EN.indd5IG-DC2A.EN.indd5 2012/04/1110:54:042012/04/1110:54:04

IG-DC2
E-4
PARTS NAME
Air Outlet
Main Unit
MAIN UNIT • CONTROL PANEL/DISPLAY
BACK ACCESSORIES
Turbo
Button
Turbo
Light
(purple)
Operation Light Ion sign (blue)
Unit
Replacing
Light
(red)
(See E-7) (See E-7)
(See E-10)
Car Adapter
Unit Connection Plug
Cigar Plug
(With 5A glass tube fuse)
Connect to the cigar lighter socket
in the vehicle.
Cord
* If the Plasmacluster Ion Generating Unit replacement time comes,
Unit Replacing Light lights up.
*
(Inside of main unit)
Plasmacluster Ion
Generating Unit
Power Input
Terminal
Filter Cover
Air Intake
(Filter)
Do not remove
the cushioning
material from the
back of the cover.
Operation
Button
IG-DC2A.EN.indd6IG-DC2A.EN.indd6 2012/04/1110:54:042012/04/1110:54:04

ENGLISH
E-5
Connecting the car adapter and installing the unit
INSTALLATION GUIDANCE
Remove the filter
cover.
1
1
2
Filter
cover
Remove
Insert the car adapter's unit
connection plug securely into
the unit power input terminal.
2
Route the cord in one of the ways
shown in the diagram, according
to the place of installation, then
attach the filter cover.
3
Cord
Use one
of these
routes.
Hook
Insert it from
lower side
Attach
Upper
Bottom
• Be careful the cord does not get
caught in the filter cover.
Insert the cigar plug into the
cigar lighter socket.
4
• Be sure to remove any dirt from the
cigar lighter socket. Failure to do so
could cause faulty contact or fire.
Cigar
plug
Cigar lighter
socket
Lock
part
IG-DC2A.EN.indd7IG-DC2A.EN.indd7 2012/04/1110:54:052012/04/1110:54:05

E-6
Set the unit in the cup holder
with its air outlets facing in
the desired direction.
5
Cautions on wiring the car adapter
• Do not let the cord touch or get caught in the seat rails, shift lever or other
moving parts.
• Wire in such a way that the cord does not get in the way of the driver.
• Consider the movement of the seats (forward/backward, swiveling or
reclining) when wiring.
• Do not bend the cord extremely or compress it.
• Be sure to place on a stable location. (Do not put in a commercially
available cup holder or other unstable place.)
• Do not obstruct the air inlet or outlet.
• Keep the unit away from the vehicle’s in-glass antenna. Failure to do so
could cause noise in the radio.
• If there should be noise in a TV or radio located in the same car, or if an
atomic clock in the car should not display the time properly, move the unit
away from the TV, radio, atomic clock, etc.
•
If the unit is installed directly in front of the car climate control’s outlets, the
unit could get hot when the climate control is operating in the heating mode.
• The unit could get scratched by the vibrations of the vehicle, etc.
Cautions on installation
• Separate the main unit from electronic
key of vehicle by 30cm or more.
Otherwise, it may interferes with
electronic wave of main unit and the
electronic key may not be recognized.
Air outlet
Separate the main unit from electronic
key of vehicle by 30cm or more.
IG-DC2A.EN.indd8IG-DC2A.EN.indd8 2012/04/1110:54:062012/04/1110:54:06

ENGLISH
E-7
OPERATION
LOW
HIGH
'OFF'
If you want to operate the
product in silence
Release high-density
Plasmacluster ions quietly.
If you want to operate the
product at strong flow rate
Release high-density
Plasmacluster ions at high fan
speed.
When you want to remove the odor quickly
Approximately two fold Plasmacluster ion is of
"HIGH" fan speed is discharged with stronger
air volume.
• After smoking
• After eating in a vehicle
• When you are conscious about odor of air
conditioner
Power 'OFF'.
If the vehicle's engine is turned off and the vehicle is stopped while the unit is
operating, the unit resumes operating in the same mode when the vehicle's
engine is started back up.
•
For preventing you from forgetting to turn OFF the product, it automatically
stops after 8 hours from the operation is started, however, if the main unit
is operated even if the key of the vehicle is pulled out or the engine switch
is turned OFF, pull out the cigar plug for preventing the dead battery.
While the operation is stopped
• The “TURBO” operation is enabled by
just pressing the Turbo Button. When
the “TURBO” operation is executed by
pressing the button, the operation is
stopped by pressing the Turbo Button or
Operation Button.
Press
Engine interlocking function
TURBO
In operation
• The operation is switched to “TURBO”
operation by pressing the Turbo Button.
•
If you press the Turbo Button or Operation
Button during the “TURBO” operation,
the mode returns to the operation mode
immediately before the “TURBO” operation.
To select the preferred mode
IG-DC2A.EN.indd9IG-DC2A.EN.indd9 2012/04/1817:44:312012/04/1817:44:31

E-8
CLEANING AND MAINTENANCE
MAIN UNIT Every month or more often if necessary
<For Stubborn Dirt> Use water and a mild detergent. And then, wipe with a
wet cloth. Make sure to dry out the main unit. Every
FILTER Frequently as necessary
Wipe with a dry soft cloth.t
The filter must be cleaned regularly in order to maintain the ion density.
Filter soiling depends on the usage environment, so clean the filter
frequently as necessary.
By frequently cleaning, Plasmacluster ion can be released efficiently.
Gently remove dust
from the filter of
back side by using a
vacuum cleaner.
<For Stubborn Dirt>
• Remove and rinse in water. (Use a soft sponge if the dirt
does not come off easily.)
Be careful the cushioning material does not come off.
• Do not press the vacuum cleaner strongly against the filter, or the filter could be
damaged.
• If using synthetic kitchen detergent, rinse well to remove all traces of the detergent.
Also, be sure to dry the filter in the shade.
• Dry the product in a shaded area so that water drop does not remain in gap between
filter cover and filter.
Filter
Rinse Wipe with a dry cloth. Reattach
(Dry in the shade.)
IG-DC2A.EN.indd10IG-DC2A.EN.indd10 2012/04/1110:54:062012/04/1110:54:06

ENGLISH
E-9
Plasmacluster Ion Generating Unit (electrode section)
Every 6 months or more often if necessary
If such a message is displayed, carry out the maintenance of the
Plasmacluster Ion Generating Unit (electrode section).
Dust, fluorine resin, or silicone may be attached and the Plasmacluster ion
may not be generated depending on the use environment*. Carry out the
maintenance periodically.
Remove the Plasmacluster Ion Generating Unit from the main unit referencing
“Plasmacluster Ion Generating Unit Replacement”. (See E-11)
Remove dust or foreign object attached to the electrode (needle) of the Plasmacluster
Ion Generating Unit or periphery with a cotton swab.
The Operation Lights “LOW” and “HIGH” (blue) flash
at the same time and the operation is stopped.
Electrode
section
Do not
touch the
connection
terminal
[Before cleaning] [After cleaning]
Flashing (blue)
Cotton
swab
• Do not touch the electrode section. (Doing so could lead to injury.)
• Do not transform the electrode section. (Doing so could lead to damage.)
• Do not touch the connection terminals. (Doing so could lead to damage.)
• Please damp the tip of a cotton swab with little water, if the dirt does not come off
easily.
* Places where hair care products (split end coatings, hair mousses, hair treatments,
etc.), cosmetics, antiperspirants, antistatic agents, waterproofing sprays, polishes,
glass cleaners, chemicalimpregnated clothes, wax, etc. are used or smoking
environment.
Electrode (needle)
Circumference
of base part
IG-DC2A.EN.indd11IG-DC2A.EN.indd11 2012/04/1110:54:072012/04/1110:54:07

E-10
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
If the total operating time passes approximately 17,500 hours (approx. 6
years if the product is operated 8 hours a day), Unit Replacing Light flashes
to notify you of the replacement time of the unit.
* The unit replacement period is same even if the product is operated in any
operation mode.
Elapsed Time
Replacement of Plasmacluster Ion Generating Unit
Display Message
* When turned back on after the unit is replaced, the Unit Replacing Light is off.
(See E-11)
Plasmacluster Ion Generating Unit
Model Number:
IZ-C75CE
Beginning to use
Approx. 17,500 hours
(approx. 6 years when
operated 8 hours a
day)
Approx. 19,000 hours
(approx. 6 years and
6 months when
operated 8 hours a
day)
<For Disposal>
Please dispose the used Plasmacluster
Ion Generating Unit according to any local
laws and regulations.
-materials-
• Case : Polystyrene
•
Unit : Polystyrene Terephthalate, Electric
"UNIT" is flashing (red)
Stop working
parts
Replace the
Plasmacluster Ion
Generating Unit
"UNIT" is flashing rapidly
(red)
IG-DC2A.EN.indd12IG-DC2A.EN.indd12 2012/04/1110:54:072012/04/1110:54:07

ENGLISH
E-11
How to replace Plasmacluster Ion Generating Unit
Remove the filter
cover and pull
out the plug for
connecting the
main unit
1
1
2
Filter
cover
Remove
Filter
cover
Attach
With a
coin or
other item
Plasmacluster
Ion Generating
Unit
Unscrew the screw
that fixes the
Plasmacluster Ion
Generating Unit
and remove it
2
Attach a new
Plasmacluster Ion
Generating Unit and
fix it with a screw
Connect the plug for
connecting the main
unit and attach the
filter cover
Insert the cigar plug in the cigar lighter socket and check
the Unit Replacing Light is turned OFF
3
4
5
• After the replacement, you may feel the sound “Zi, Zi ...”(sound generated by
Plasmacluster ion) become larger, however, you feel it because the Plasmacluster
Ion Generating Unit is replaced with a new one. It is not a failure.
IG-DC2A.EN.indd13IG-DC2A.EN.indd13 2012/04/1110:54:082012/04/1110:54:08

E-12
REPLACING THE FUSE
HOW TO REPLACE
SPECIFICATIONS
*1 It is the index of capacity that approximately 25,000 ions blown out to the air can
be measured at the point near the center of the space (0.5m height from floor)
when the air volume is "HIGH" by placing this product at the place supposing a cup
holder beside the driver's seat.
*2
Space corresponding to a cabin measuring 1.5 (width) x 2.4 (depth) x 1.0 (height) meters
* Some specifications may be changed for improvement purposes.
Model
Rated voltage
Applicable interior volume
*1
Operation mode
Power consumption
Ion density
Operating noise level
Outer dimensions
Weight
DC12V
Approx.
3.6
m3 *2
1.1W 1.8W
23dB
Approx. 270g (Not including car adapter)
IG-DC2A
HIGHLOW
Turn the tip of the cigar plug and remove it.
1
5A glass
tube fuse
New fuse
Insert the new fuse, then
reassemble as before.
2
• Be sure to replace with a 5A glass tube
fuse (commercially available).
29dB
Cylindrical, 76 mm upper section diameter / 65 mm lower section
diameter x 150 mm height (Not including car adapter)
ACCESSORIES Car Adapter / Operation manual
2.7W
TURBO
33dB
Approx. 7,000 ions/cm3
Approx. 25,000 ions/cm3Approx. 50,000 ions/cm3
IG-DC2A.EN.indd14IG-DC2A.EN.indd14 2012/04/1110:54:092012/04/1110:54:09

ENGLISH
E-13
TROUBLESHOOTING
Problem WHAT TO DO
The Plasmacluster Ion Generator
does not work.
• Is a Car Adapter connected properly?
Please be connected definitely. (See E-5)
• Does not a fuse blow?
Replace with a new fuse. (See E-12)
Flashing rapidly (red)
Flashing (blue)
• If the main unit is operated even if the key of
the vehicle is pulled out or the engine switch
is turned OFF, pull out the cigar plug for
preventing the dead battery. (See E-7)
• With the vehicle that the power is supplied to
the cigar socket lighter even if the engine of
vehicle is switched OFF, the engine interlocking
function cannot be used.
• Press the Operation Button or the Turbo Button.
For preventing you from forgetting to turn them
OFF, the operation is automatically stopped in
8 hours after the operation is started.
• The Plasmacluster Ion is not generated. Press
the Operation Button again and restart the
operation.
• Clean the electrode section of the
Plasmacluster Ion Generating Unit. (See E-9)
• Is the Plasmacluster Ion Generating Unit
installed correctly? Pull out the Plasmacluster
Ion Generating Unit and insert it to the end
again, and then press the Operation Button.
(See E-11)
If the light flashes repeatedly, contact the store
you purchased or SHARP authorized service
center.
• It is over the usage period of main unit. Replace
with new Plasmacluster Ion Generating Unit.
(See E-11)
• If the unit replacement period is exceeded, the
Unit Replacing Light (red) flashes rapidly and
the operation is stopped.
The operation does not stop
although the engine of vehicle is
switched OFF
The operation is stopped
The Operation Lights "LOW"
and "HIGH" (blue) flash at the
same time and the operation is
stopped
The Unit Replacing Light flashes
rapidly and the operation is
stopped
The product does not operate in
conjunction with engine
IG-DC2A.EN.indd15IG-DC2A.EN.indd15 2012/04/1110:54:092012/04/1110:54:09

E-14
TROUBLESHOOTING
Problem WHAT TO DO
• Failure
Unplug and contact the store you purchased or
SHARP authorized service center.
Other indication
A discontinuous noise is heard.
A clicking or ticking sound
comes from the unit.
• Clicking or ticking sound may be audible when
the unit is generating ions. (The interval of
sound may change.) You may feel the sound
becomes large or small depending on use
environment or operation mode, however, the
effect of Plasmacluster ion is not changed.
• Dust may block the filter, clean the filter. (See
E-8)
IG-DC2A.EN.indd16IG-DC2A.EN.indd16 2012/04/1110:54:102012/04/1110:54:10

中文
中文
感謝您購買 SHARP 生產的 HD
PCI 抗菌機。在使用 HD
PCI 抗菌機前請詳細
閱讀本手冊。
閱讀後請妥善保存本手冊,以便日後查閱。
關於本手冊中提供的資訊,有可能無通知而改變的情况。
C-1
目錄
重要安全事項..........................................................C-2
• 警告 .......................................................................C-2
• 操作注意事項 ...........................................................C-3
各部分名稱..............................................................C-4
• 主機 • 操作面板 / 顯示 .........................................................C-4
• 背面/附件
...........................................................................C-4
安裝位置 ..............................................................................C-5
主機操作 ..............................................................................C-7
保養與清潔..........................................................................C-8
• 過濾網 ..................................................................................C-8
• 主機......................................................................................C-8
• HD 離子產生器.......................................................................C-9
HD 離子產生器的更換......................................................C-10
更換保險絲........................................................................C-12
規格.....................................................................................C-12
故障時的解決方法...........................................................C-13
• 雖然 IG-DC2A 能夠抑制和去除懸浮的病毒以及其他污染物,但並不
能夠營造一個完全無菌的環境。SHARP對該產品防止微生物感染的
能力不提供保證。
•
為穩定釋出高濃度的 PCI,需要定期更換安裝於 IG-DC2A內部的HD
離子產生器 *。
* 在 8 小時連續運行的情況下,大約每 6 年(17,500 小時)需要進行一次更換;
如果未對 HD 離子產生器進行更換,IG-DC2A 將在大約6年6個月(19,000 小
時)後停止運行。
IG-DC2A.CH.indd3IG-DC2A.CH.indd3 2012/04/1111:06:442012/04/1111:06:44

C-2
重要安全事項
使用前請務必閱讀並予以遵守。
警告 - 為減少觸電、火災或受傷等危險:
在使用電器產品時,必須遵守基本安全預防措施,包括以下各方面:
• 請勿在駕駛中進行開關操作。(否則可能會導致意外事故)
• 切勿設置在妨礙前方視野的場所、妨礙駕駛的場所、對乘客導致危險的場所。(否則可能
會導致事故或受傷)
• 切勿設置在陽光直射的場所。(否則可能會導致變形或故障)
• 12V 汽車專用,切勿用於其他車輛。請勿在大型卡車、公共汽車等 24V 車輛上使用。(否則
可能會導致漏電、觸電)
• 切勿損壞電線、或對電線進行加工。此外,切勿使用受損的電線。(否則受損的部位可能
會因短路而令電線熔化,導致火災)
電線受損時,請向您購買本機的經銷商或 SHARP 授權的服務中心諮詢。
• 拔出點煙器插頭、主機連接用插頭時,切勿拉扯電線。(否則電線可能會受損而導致火災、
觸電)
• 切勿用濕手拔插點煙器插頭、主機連接用插頭。(否則可能會導致觸電)
• 駕駛時,切勿摔落或撞擊本機。(否則可能會導致受傷、故障)
萬一摔落本機而導致破損時,請向您購買本機的經銷商或 SHARP 授權的服務中心諮詢。如
果繼續使用,可能會導致火災、觸電。
• 切勿進行改裝。此外,非修理技術人員切勿進行分解、修理。(否則可能會導致火災、觸電、
受傷)
關於修理,請向您購買本機的經銷商或 SHARP 授權的服務中心諮詢。
• 切勿從空氣吹出口、吸入口將飲用水、煙灰、金屬物品或易燃物品落入內部。
特別是家中有小孩時,請加以注意。萬一水、異物進入內部,請將點煙器插頭從點煙器插
座中拔出。(如果繼續使用,可能會導致火災、觸電)
請向您購買本機的經銷商或 SHARP 授權的服務中心諮詢。
• 切勿用油類、酒精、苯、香蕉水擦拭本機或噴上噴霧劑、殺蟲劑。如附著上述物質,須立
即擦拭乾淨。(否則可能會導致產生裂紋、觸電、著火)
• 請勿放置在有油煙或濕氣的環境中,例如烹飪台或加濕機旁邊等。(否則可能會導致變形
或故障)
• 請勿放置在暖氣設備附近,例如暖風機的吹出口附近等。(否則可能會導致變形或故障)
• 汽車適配器須使用專用產品,點煙器插頭需切實地插入至底部。(如果點煙器插頭未插入
至底部則會發熱,不僅可能會導致點煙器插座的周圍變形,並可能會導致火災)
• 保險絲熔斷時,務必更換為 5A 玻璃管保險絲(市售產品)。絕對不得使用金屬絲等代替保
險絲。(如果使用指定保險絲以外的物品則會發熱,可能會導致火災)
• 維護保養時,務必從點煙器插座中將點煙器插頭拔出。(否則可能會導致觸電、受傷)
• 長時間不使用時,務必將點煙器插頭從點煙器插座中拔出。(否則絕緣劣化可能會導致觸
電、漏電火災)
• 煙灰盒與點煙器插座一體時,須在煙灰確實熄滅後再使用。
離開汽車時,須將點煙器插頭拔下,關閉煙灰盒的外蓋。(否則煙頭的殘火可能會導致火災)
• 除非得到監護人或負責其安全人士的適當監督或指導,否則,本機不適合身體官能或心智
能力退化者,或缺乏操作經驗和知識(包括兒童)使用。
• 兒童應受到適當的監管,以確保不會以此機器作玩具。
IG-DC2A.CH.indd4IG-DC2A.CH.indd4 2012/04/1111:06:442012/04/1111:06:44

中文
C-3
操作注意事項:
• 切勿觸摸汽車適配器的點煙器插頭(點煙器插座)的金屬部位。(汽車停止後,由於點煙
器插頭的金屬部位溫度很高,可能會導致燙傷)
• 切勿放置在市售的杯架、晃動的台子上或傾斜之處等不穩定的場所。(否則跌落時可能會
導致受傷、故障)
• 使用室內薰蒸型(冒煙型)殺蟲劑或除臭劑時,須將本機移動至其他場所。
否則藥劑成分可能會積蓄在機械內部,然後從空氣吹出口釋放出來,不利健康。
• 主機可能會從杯架上飛出時(崎嶇的道路、台階等),請減速或將主機從杯架中取出。(否
則可能會導致受傷或主機發生故障)
• 在離子產生器附近,切勿使用添加有氟樹脂或硅膠的化妝品等物品 (※)。否則氟樹脂、硅
膠可能會附著在主機內部,導致無法產生離子簇。
此時,需要去除 HD 離子產生器內電極部分和電極周圍的灰塵。( 參見 C-9)
* 護髮產品(髮梢保護液、髮膠、頭髮修護產品等)、化妝品、抑汗劑、靜電防止劑、防水噴霧劑、
光亮劑、玻璃清潔劑、化學抹布、石蠟等。
IG-DC2A.CH.indd5IG-DC2A.CH.indd5 2012/04/1111:06:452012/04/1111:06:45

IG-DC2
C-4
各部分名稱
空氣吹出口
主機
主機 • 操作面板 / 顯示
背面 附件
操作按鈕 Turbo 按鈕
Turbo
運轉
指示燈
(紫色)
操作指示燈
離子
指示
燈(藍色)
HD 離子
產生器更
換指示燈
(紅色)
( 參見 C-7) ( 參見 C-7)
( 參見 C-10)
汽車適配器
主機連接用插頭
點煙器插頭
(附帶 5A 玻璃管保險絲)
車內點煙器插座連接。
電線
* HD 離子產生器時限到達時,HD 離子產生器更換指示燈會點亮。
*
( 主機內部 )
HD 離子產生器
電源輸入端子
過濾網外殼
空氣吸入口
( 過濾網 )
請不要將內面的
緩衝材料拆下。
IG-DC2A.CH.indd6IG-DC2A.CH.indd6 2012/04/1111:06:452012/04/1111:06:45
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp FU-S40E User manual

Sharp
Sharp FP-G50J User manual

Sharp
Sharp FP-F30TA User manual

Sharp
Sharp FZ-550CF User manual

Sharp
Sharp UA-PE30U User manual

Sharp
Sharp FP-J50TA User manual

Sharp
Sharp IG-NX2E User manual

Sharp
Sharp FU-28H-S User manual

Sharp
Sharp IG-ETC1A User manual

Sharp
Sharp KC-F31R User manual

Sharp
Sharp Plasmacluster FP-A28C User manual

Sharp
Sharp FP-A80U User manual

Sharp
Sharp IG-DM1Y User manual

Sharp
Sharp FP-J30J User manual

Sharp
Sharp IG-BC2E Plasmacluster Ion User manual

Sharp
Sharp KC-D51R User manual

Sharp
Sharp FU-888SV User manual

Sharp
Sharp FP-F50U-W User manual

Sharp
Sharp FP-P35CX - HEPA Air Purifier User manual

Sharp
Sharp Plasmacluster KC-C100U User manual