www.Siargo.com
MF5100V
UserManual
11
|
Page
5. Meterinstallation
Donotopenoralteranypartoftheproductwhichwouldleadtomalfunctionandirrecoverable
damage.Itwillalsoforfeitthetermsofthewarrantyandcauseliability.
Theproductatthetimeofshipmentisfullyinspectedforitsqualityandmeetsallsafetyrequirements.
Additionalsafetymeasuresduringtheinstallationshouldbeapplied.Thisincludes,butisnotlimited
totheleakageverificationprocedures,standardEDS(electrostaticdischarge)precautions,DC
voltageprecautions.Othertaskssuchascalibration,partreplacement,repair,andmaintenance
mustonlybeperformedbytrainedpersonnel.Uponrequests,themanufacturerwillprovide
necessarytechnicalsupportand/ortrainingofthepersonnel.
Checkthemanualcontrolvalvewhichshouldbeatthefullclosedstatusatthetimeofinstallation.
Flowdirectionshouldbealignedwiththearrowmarkonthemeterbody.Iftheflowingfluidmay
haveparticlesordebris,afilterisstronglyrecommendedtobeinstalledupstreamofthemeter.
Pleasefollowthefollowingstepstocompletetheinstallation:
a)Uponopeningthepackage,theproduct'sphysicalintegrityshouldbeinspectedtoensureno
visualdamage.
b)Beforeinstallationoftheproduct,pleaseensurethatthepipedebrisorparticlesoranyother
foreignmaterialsarecompletedremoved.
d)Fornon‐batterypoweroperation,connectelectricalwiresperthewiredefinitioninTable3.3.
Pleasebesureofthepowersupplyrange(i.e.,12~24VDC)andpowersupplypolarization.If
anadapterotherthantheonesuppliedbythemanufacturer,makesuretheadaptermeets
industrialstandardsandhasallsafetycertifications.
e)Forthedatacommunicationwireconnection,pleasefollowthedescriptioninTable3.3and
makesurethatthewiresarecorrectlyconnectedtotheproperportsonyourdata
device/equipment.Pleasemakesurethedatacablemeetsindustrialstandardswithproper
shielding.
f)Oncetheexternalpowerissuccessfullyconnectedorthebatteryisinstalled,theLCDshouldbe
lightedupwiththeproperinformationdisplayedworkscorrectly.
g)Slowlyopenthevalve(s)ifany,upstreamordownstreamorbothofthepipeline,followedby
slowlyopenthemanualcontrolvalveonthemeter.Andthemetershouldthenstarttomeasure
theflowinthepipeline.Note:becausethemeterhasalargedynamicalmeasurementrange,it
couldbenormalifyouseethesmallinstantflowratebeforeyouopenthevalveastherecould
besomeleakage.However,makesurethemeterreadsnullwhenthereisnoflowpresentinthe
pipeline.
h)Thiswillconcludetheinstallation.