
Contents
System- and communication configuring D7-SYS - SIMADYN D ix
Edition 12.2003
3.1.3.2 Address connections AT, AR and US..................................................................3-10
3.1.3.3 Data transfer mode, MOD input...........................................................................3-11
3.1.3.4 Firmware status, ECL, ECO connection..............................................................3-15
3.1.3.5 Status display, output YTS ..................................................................................3-15
3.1.4 Mode of operation of the couplings .....................................................................3-16
3.1.4.1 Central coupling blocks........................................................................................3-17
3.1.4.2 Transmitters and receivers..................................................................................3-18
3.1.4.3 Compatible net data structures............................................................................3-19
3.1.4.4 Number of coupling modules in a subrack ..........................................................3-20
3.1.4.5 Reorganizing a data interface..............................................................................3-20
3.2 Couplings on the subrack....................................................................................3-22
3.2.1 Local CPU coupling.............................................................................................3-22
3.2.2 Communications buffer coupling .........................................................................3-22
3.2.3 Coupling to EP3 modules....................................................................................3-23
3.3 Subrack coupling.................................................................................................3-25
3.3.1 Hardware structure..............................................................................................3-27
3.3.2 Scope of supply ...................................................................................................3-27
3.3.3 Response when "shutting down" a coupling partner...........................................3-27
3.3.4 Response when "powering-up" the master subrack............................................3-28
3.3.4.1 Acknowledging.....................................................................................................3-28
3.3.5 Restart frequency ................................................................................................3-29
3.3.6 Configuring...........................................................................................................3-30
3.4 Industrial Ethernet coupling (SINEC H1).............................................................3-31
3.4.1 Hardware and central coupling block ..................................................................3-32
3.4.1.1 Hardware .............................................................................................................3-32
3.4.1.2 Central coupling block @CSH11.........................................................................3-34
3.4.2 Communications via SINEC H1 layer 2...............................................................3-34
3.4.3 Communications via SINEC H1 layer 4...............................................................3-36
3.4.4 Communications via SINEC H1 layer 7 (STF).....................................................3-38
3.4.4.1 Address connections ...........................................................................................3-38
3.4.4.2 Communications utility, process data..................................................................3-40
3.4.4.3 Communications utility, message system............................................................3-42
3.4.5 System time.........................................................................................................3-44
3.4.6 Data quantities, sampling times...........................................................................3-44
3.4.7 NML network management..................................................................................3-45
3.5 PROFIBUS DP coupling......................................................................................3-46
3.5.1 Configuring with D7-SYS.....................................................................................3-47
3.5.1.1 Central coupling block .........................................................................................3-47
3.5.1.2 Address connections AT, AR...............................................................................3-48
3.5.1.3 SYNC/FREEZE commands.................................................................................3-49
3.5.1.4 Configuring versions of SYNC/FREEZE..............................................................3-50
3.5.1.5 Diagnostics function block...................................................................................3-54
3.5.2 Configuring with COM PROFIBUS......................................................................3-58
3.5.2.1 Harmonizing with data configured in CFC...........................................................3-58
3.5.2.2 SS52 as PROFIBUS slave ..................................................................................3-59
3.5.2.3 Loading the database..........................................................................................3-60
3.5.3 Start-up/diagnostics.............................................................................................3-61
3.5.3.1 LEDs....................................................................................................................3-61