Quick start guide CL4A-2212-EU MKII
Mini Chair Leaving Monitor
Any questions? Call us on 01246 450789
TM
Silent
Alert
PM5 Activation
Status light
Test button
Configuration
switch Cover
PP3 battery
contacts
Screw cap
Screw cap
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
PP3 Battery The light will then will flash
green several times to show the
battery voltage.
9 flashes = 9Volts in the battery.
When a battery is first fitted the
indicator light will flash red then
green a few times.
1. Install a 9 volt PP3 alkaline or lithium battery
making sure to observe the correct polarity.
If the light flashes red at this
point the battery is flat
and will need to be replaced.
To repeat the battery check remove the battery, press the test
button then re-insert the battery to start the sequence again.
CCD4A-2220-EU
CARE CALL
MINI MAGNETIC
DOOR MONITOR
USE ALKALINE PP3
9 V BATTERY ONLY
Batch 06/01/14
www.silent-alert.co.uk
Clofield Ltd. UK
Tel: 01246-260045
Keys 1-4 System
Channel
Key 5=10 Sec Delay
Key 6=20 Sec Delay
Keys 5+6=30 Sec Delay
Key 7 Leave ON
Key 8 Not Used
USE WITH MAGNET SUPPLIED
Pressure pad
socket
Configuration switches shown
with cover removed. Do not alter
these without referring to page 2
2. The monitor is activated using a chair pressure pad
(PM5).
The monitor may transmit the first
time the connection is made, this
is normal.
Plug the PM5 plug into the
socket on the monitor
The 3.5mm jack socket will trigger
the unit on a short circuit only.
3. Place the pad under the chair cushion ensuring
the pad is not folded.
When installing the pad make sure the cable can't
cause a trip hazard.
WARNING! Your device and its accessories are not toys. They may contain small parts. Keep them out of the reach of small children.
4. As the user stands up the monitor will send a
signal to the Pager or SignWave.
5. Fidget delay To prevent the unit triggering
when the user changes position in
their seat the monitor has a
'fidget' delay.
If the person releases the
pressure from the pad a timer will
start, this is indicated by the green
light flashing on the monitor.
After 3 - 4 seconds the monitor will trigger. However,
if the person sits back down the light will switch off
and the monitor will not transmit.
1 2 3 4 5 6 7 8
If this delay is not required or if
the monitor is being used to detect
an open circuit switch key 6 to on.
The unit will now send radio as
soon as it is triggered.