Speco O2DP9 User manual

O2DP9
Owner’s Manual
O2DP9

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
2
Caution
Any changes or modifications in construction of this device which are not explicitly
approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generate, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into and outlet on a circuit different from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician for help.
Directions
Be careful not to cause any physical damage by dropping or throwing the camera.
Especially keep the device out of reach from children.
Do not disassemble the camera. No after service is assumed when disassembled.
Use only power adapters compatible with the unit.
Be careful to prevent moisture or water penetration into the unit. Particular attention is
needed when installing the unit. The screw holes for the installation screws and pipe should
be maintained water tight during the whole life time of the product.
All the electrical connection wires running into the unit should be prepared so that water from
the outside cannot flow into the unit through the surface of the wires. Penetration of the
moisture through the wire for extended period can cause malfunction of the unit or
deteriorated image.

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
3
Revision History
Date
Revision
Details
May 15th, 2014
1.0
First manual revision creation.

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
4
Contents
1. Introduction....................................................................................................................................................5
1.1. Overview...................................................................................................................................................5
1.2. Specification..............................................................................................................................................6
1.3. Applications of O2DP9..............................................................................................................................7
2. Product Description ......................................................................................................................................8
2.1. Contents ...................................................................................................................................................8
2.2. Product Preview........................................................................................................................................8
2.3. Physical description..................................................................................................................................9
2.3.1. External View..................................................................................................................................9
2.3.2. Dimension.......................................................................................................................................9
2.3.3. External Connector.......................................................................................................................10
2.4. Functional Description............................................................................................................................11
3. On Site Installation ......................................................................................................................................12
4. Getting Started.............................................................................................................................................13
4.1. PC Requirement.....................................................................................................................................13
4.2. Quick Installation Guide..........................................................................................................................14
4.2.1. Connect PC and O2DP9 to network. ...........................................................................................14
4.2.2. Install Speco-NVR and set IP parameters on O2DP9..................................................................14
4.2.3. Remote video connection to O2DP9............................................................................................17
4.2.4. Additional settings through connection to the Admin Page..........................................................19
5. Trouble Shooting .........................................................................................................................................20
5.1. No power is applied................................................................................................................................20
5.2. Cannot connect to the Video..................................................................................................................21
5.3. Windows Vista or Windows 7 .................................................................................................................22
5.4. Technical Assistance...............................................................................................................................25

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
5
1. Introduction
1.1. Overview
O2DP9 is multi-codec (H.264, MJPEG) IP camera (or network camera) built with embedded software and
hardware technology in pancake housing. It enables real time transmission of video of up to 1080P. Remote
clients can connect to O2DP9 for the real time video data through various client solutions running on PC or
smart device.
O2DP9 is specialized in video transmission which economic and practical products removing audio, sensor,
replay, etc and the videos can be only available in the field and place where needed.
Embedded PoE (Power over Ethernet, IEEE 802.3af) will enable the owner to reduce TCO (Total Cost of
Ownership) by reducing on-site wiring works for the installation.

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
6
1.2. Specification
Camera
Image sensor
Progressive scan 1/2.9 inch CMOS 2.0M pixels
Full resolution
1,920 x 1,080 pixels (Full HD)
Min. illumination
0.2Lux (Color, DSS On), 0.00 Lux (IR LED On)
S/N Ratio
50dB or more
White Balance
AWB
DSS
Supported
WDR
Supported
Lens
3.7mm, F2.5
Day & Night
Supported (TDN & IR LED)
IR LED
12EA
Video
Compression method
Simultaneous Dual Codec (H.264 / MJPEG)
Resolution
1920x1080@30fps
Multi-Profile Streaming
- 3 simultaneous video profiles
- Select the codec type, resolution and frame rates for each profile.
Intelligent Bit-Rate Control
VBR or CBR
PTZ
Digital PTZ & video crop
Image Setting
Text overlay, Privacy mask, De-interlace filter
Motion detection
3 regions
Network
Network Protocol
- IPv4/v6, TCP, UDP, IGMP, ICMP, ICMPv6, ARP, RARP, PPPoE, RTCP
- RTP, RTSP, SDP, HTTP, HTTPS, SMTP, FTP, DHCP, UPnP
- NTP, DNS, DynDNS, SOCKS
Dynamic IP
Speco DDNS (free of charge)
Security
- User ID & Password protection, IP address filtering
- HTTPS encryption, Digest Authentication, User Access Log
Streaming method
- RTSP streaming with proprietary format for control informations
- Standard RTSP streaming
- HTTP streaming

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
7
External Terminals
LAN
10/100BaseT LAN (auto MDIX)
Power
DC 12V input
Factory Reset
Supported
Alternate Power
Standard PoE
IEEE802.3af Supported
Alarm & Event
Intelligent Video
Motion Detection
Alarm Triggers
Intelligent Video
Alarm Events
Video file upload(FTP), Still Image(Email)
Alarm Buffer (Audio/Video)
configurable Pre-alarm (5~10 sec) & Post-alarm (10~30 sec)
Client Software
Speco NVR
Windows XP/Vista/7 (free of charge)
Speco ONSIP
Android™, iPhone® , iPad® (free of charge)
Miscellaneous
Operating Temperature
0C ~ 45C (32F~113F)
Operation Humidity
8~80% RH
Power
DC 12V, 0.6A
Dimensions(W x H x D)
Ø122mm(4.8”) x 55mm(2.1”)
Weight
0.3Kg (0.66Lb)
Casing
PC/ABS
Approvals
FCC, CE, KCC, RoHS
Package information
Unit, CD, mounting screws
Optional Items
Adapter
DC 12V, 1.5A
1.3. Applications of O2DP9
Small Office, Home environment, Personal user.
Security surveillance (buildings, stores, manufacturing facilities, parking lots, banks, government facilities,
military, etc.)
Remote monitoring (hospitals, kindergartens, traffic, public areas, etc.)
Weather and environmental observation

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
8
2. Product Description
2.1. Contents
The product package contains followings :
Contents
Description
Remarks
O2DP9
IP camera O2DP9 main unit
Accessories
Screws (3 pieces of 1 type),
Anchors (3 pieces of 1 type),
L-type wrench 1EA
CD
Software & User’s Guide
Quick Reference Guide
Quick installation guide
Power Adaptor
Default built in standard PoE module
(IEEE802.3af)
12V DC Adaptor
(Optional item)
2.2. Product Preview
O2DP9
IP Installer
VMS Software (Speco NVR)
Main Unit
PC software to allocate an IP
address to the IP Camera
PC software to view and record the
A/V streaming data transmitted from
IP camera.
(Simultaneous support of up to 64
IP cameras@D1)

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
9
2.3. Physical description
2.3.1. External View
Figure 2-1. External view of O2DP9
2.3.2. Dimension
Unit : mm
Figure 2-2. Dimension

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
10
2.3.3. External Connector
Figure 2-3. Connector for external connection
Network (LAN)
Power

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
11
2.4. Functional Description
Power : Power input for supplying 12V DC power.
Caution : If O2DP9 is powered by PoE, do not plug in DC Jack with active DC power
into DC power connector.
Network (LAN)
100Mbps Ethernet connector (RJ-45) with PoE standard (802.3af). LED on the Ethernet connector shows
the status of O2DP9 as the followings:
- Status LED (It will be lit in green or red depending on the status)
①Green : Green color indicates that the camera is in normal operation mode. Continuous green
indicates that data transmission is possible..
Factory Default Switch
Factory default switch is provided for returning the IP camera to factory default state. Unscrew the cover
to access the switch. Press the switch about 5 seconds while power is applied to return to factory default
state
Factory Default Switch
Status LED

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
12
3. On Site Installation
Use cables and conduits that are suitable for the installation. Particular attention should be paid in the
installation so that no moisture is allowed to penetrate into the unit through the cables or conduits during the life
time of the product. Products of which the internal parts are exposed to moisture because of improper
installation are not covered by warranty
1. Remove the top cover.
2. Fix the base on the wall.
3. Adjust the rotational position of the camera for desired viewing of the site.
4. Place top cover.

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
13
4. Getting Started
Brief information for first time operation of O2DP9 is provided in this chapter.
4.1. PC Requirement
Audio/Video streaming data received from O2DP9 can be displayed or stored in a PC running client programs.
Minimum requirement of the PC is described below:
ITEM
Minimum Requirement
Recommended Specification
CPU
Intel Core i3 3Ghz
Intel Core i7
Main Memory
2GB
4GB
Operating System*
Windows XP
Windows 7 (64bit)
Web Browser
Internet Explorer 8, 9
Internet Explorer 8, 9
Graphic Card
Video RAM 256MB
Resolution 1920x1080
Video RAM 1GB
Higher than 1920x1080
Network
10 Base-T Ethernet
100 Base-T Ethernet
* Operating Systems supported: Windows 2000 Professional, Windows XP / Vista / 7

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
14
4.2. Quick Installation Guide
4.2.1. Connect PC and O2DP9 to network.
1. Prepare a PC to run programs for the installation and video connection
(PC is needed to assign IP address to O2DP9)
2. In the case of using PoE, connect the PC and O2DP9 to the network using one of the following ways. If
your LAN Switch does not support standard PoE, connect O2DP9 as shown in dotted line in Figure 4-1.
The DC power is applied through DC adapter.
Figure 4-1. Power and network connection
4.2.2. Install Speco-NVR and set IP parameters on O2DP9
Speco-NVR is a multi-channel VMS program for the IP camera. Install Speco-NVR on remote PC to connect
to these products. It is needed to assign connection information to Speco-NVR program before connection.
Insert the CD provided with product into the PC and install Speco-NVR.
LAN switch with
standard POE
(802.3af)
LAN switch
DC adaptor

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
15
Figure 4-2. Speco-NVR
Follow the sequence below for setting the IP parameter
1. Run ONSIP installer
2. Click ①in ONSIP installer window.> Double click on ②> Fill in ④> make a selection in ⑤> Fill the
parameters in ⑥
3. Click on ⑨to apply the settings.
4. You can connect to admin page by clicking on ⑩.
Admin Page Button
ONSIP Installer

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
16
Click on the field in ③for sorting and rearranging the list.
Select network mode that best suits from the drop down list in ⑤. You can choose either Static or
ADSL and Auto (DHCP), respectively. If ADSL and Auto are selected, the fields in ⑥is
deactivated.
In case of ADSL, fill the User Name and Password in ⑧with the values provided by your ISP.
If DDNS service is needed, Check at the box and fill the empty field with hostname you want in ⑦.
1
2
3
6
4
9
5
7
8
10

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
17
4.2.3. Remote video connection to O2DP9
1. Connection through Web Viewer
Web Viewer offers simplest way of video connection to O2DP9. For video connection, enter the IP
address of O2DP9 in the URL window of Internet Explorer as:
Note : Active-X module should be installed on your PC before actual connection. If your PC is
not connected to the internet, you cannot download Active-X module. Most convenient way of
installing the Active-X module is installing Speco-NVR which is available from the CD or our
web site.
Figure 4-3. Web Viewer
Default ID and password of Admin Page are “admin”, “1234”.
For more detailed information, please refer to the “Configuration_Guide”Guide.
Connection to Admin Page
Basic Control
[e.g.] Port 80
[e.g.] Port 8080
Can be omitted the
default port of 80

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
18
1. Connection through Speco-NVR
Click the camera assignment button for setting the camera address. Input the description, address,
Ch#, User ID, Password and port and then click the save button. After assignment procedure, you must
click the SAVE button. You can see the live video when you click the live view button as below. When
you exit Speco-NVR, you have to input the ID/PW, admin/1234. Details for Speco-NVR can be found in
[Speco-NVR User’s Guide].
Figure 4-4. Speco-NVR
Camera Assignment
Live view
Exit Program
Default ID/PW: admin/1234
Camera Assignment
Example
Save

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
19
4.2.4. Additional settings through connection to the Admin Page
All parameters of the camera are factory default out of the box. For a more sophisticated target application,
parameters need to be changed through the admin page. The admin page can be connected through
“http://IP_Address:Port_Number/admin.htm”
ID and password of the administrator are required. Default ID and password are “admin”, “1234”.
It is highly recommended to change the ID and password to prevent illegal access to the IP camera.
For more detailed information, Please refer to the “Configuration_Guide”Guide.

O
O2
2D
DP
P9
9
O
Ow
wn
ne
er
r’
’s
s
M
Ma
an
nu
ua
al
l
Rev.1.0 (May. 2014)
20
5. Trouble Shooting
5.1. No power is applied
In case of Standard PoE (Power over Ethernet)
Power supply through standard PoE is possible only when the following conditions are met.
1. Standard PoE is supported on the product.
2. The LAN switch supports standard PoE.
Make sure that both the IP camera and the LAN switch support standard PoE (IEEE 802.3af)
In case of DC adaptor
If PoE is not applied, the power and network connection should be made through separate cables.
It is recommended to use DC adaptor supplied by provider for the feeding of the power. In case of
replacing the DC power supply, make sure that the power supply meets with the power
requirement of the IP camera to prevent damage or malfunction.
Table of contents
Other Speco IP Camera manuals

Speco
Speco OINT03D User manual

Speco
Speco Intensifier OiD4 User manual

Speco
Speco O2VB1V User manual

Speco
Speco Intensifier O2iTC23 User manual

Speco
Speco VLDT4W User manual

Speco
Speco O2MD2 User manual

Speco
Speco O3FDP9 User manual

Speco
Speco O4D1 User manual

Speco
Speco O3VFDM User manual

Speco
Speco O4VLB5 User manual
Popular IP Camera manuals by other brands

TP-Link
TP-Link Kasa Cam Outdoor Quick installation guide

Ganz
Ganz PixelIPro Series ZN-B2MAP user manual

Provision ISR
Provision ISR PT-737 Quick installation manual

Concept Pro
Concept Pro CVP9328DNIR-AHD user manual

FLIR
FLIR Quasar CM-6206-H1-I Quick installation guide

ALIBI
ALIBI ALI-BC5010VF Quick installation and user guide