IU_Pulse2users_easy_01_eng
Penalty
After four attempts to enter an incorrect code, the lock starts a 4-minute delay period. Each attempt to enter the code
within the 4 minutes delay period restarts the count.
Low battery warning
A series of beeps while opening indicates a low battery level.
Replace immediately the low battery with a new Alkaline battery.
Sound signals
A double beep normally indicates a correct
operation. A long beep indicates an incorrect
operation and the
end of the operation itself.
Reccomendations
Do not use easily identifiable codes such as 123456, dates of birth or other personal information.
Opening
(It is recommended to change the factory code before use and to safely store the new code)
Enter the opening code (default Manager code 123456).
If the code is correct, the keypad will beep twice.
If programmed, the time delay count starts. The LED flashes every 2 seconds.
A beep every 2 seconds indicates the end of the time delay count.
Enter the opening code. The keypad beeps twice.
Open the safe door within 4 seconds
(with motorlock EM6050, 2 beeps and 2 LED flashes are produced when the lock re-closes).
Change code
(Default Manager code “123456”. Safely store the new code and perform various opening / closing tests before closing the safe door).
To be performed with the door open!
Press and hold until the double beep. The LED remains on.
Perform various opening / closing tests before closing the safe door.
Press and hold until the double beep. The LED remains on.
Enter the code to be associated with the user.
Enter again the code to confirm it.
Press and hold until the double beep. The LED remains on.
The keypad beeps twice. The user is deleted.
Press and hold until the double beep. The LED remains on.
Enter the sequence of numbers from 1 to 0. A confirmation beep is given for each key.
A damaged key is indicated with a long beep
Time delay
(Time Delay programmable from 0 to 99 minutes; Open Window from 1 to 19 minutes)
Press and hold until the double beep. The LED remains on.
Enter the Manager code. The keypad beeps twice.
Enter the values for the time delay and the open window in two digits (e.g. 10 and 05).
Confirm the values for the time delay and the open window in two digits (e.g. 10 and 05).
Attention, the time delay can only be lowered in the open window.