1 2
Element Function
1 Infrared lens IR measurement
2 4-point laser Measuring spot marking
3 Humidity probe (only H1) Measures the relative humidity
4 Trigger - Switches the instrument on.
- Starts / ends a measurement.
5 Battery compartment Contains 3x AA batteries.
6 USB interface / probe
connection socket
- For connecting the instrument to the PC to
connect to the EasyClimate software.
- Connection of a probe.
7 - Joystick for confirming a selection.
- For navigating in the menu
8 ESC Takes the user a step back in the menu selection.
9 Switches the testo 835 on or off.
10
Saves the measured readings.
11
Setting emissivity
12 HOLD / SCAN - Scan: while the trigger is held down and the
measurement is carried out.
- Hold: displays the measured values.
13 Time Displays the current time.
14 Reading display Displays the measured readings.
Max
[°C/°F]
Min
Surface temperature (IR)
Max. IR temperature
IR temperature
Min. IR temperature
[°C/°F]
Differential (surface temperature - external probe
temperature)
TC temperature
IR temperature
Temperature difference TC / IR measurement
TC probe must be connected.
[%RH]
[°C/°F]
[°Ctd/°Ftd])
Humidity measurement (environment + dewpoint +
IR) (only H1)
Ambient humidity
IR temperature
Ambient dewpoint temperature
Element Function
[%RH]
[°C/°F]
[°Ctd/°Ftd])
Humidity measurement (environment and
dewpoint) – ambient temperature (only H1)
Ambient humidity
Ambient temperature
Ambient dewpoint temperature.
Max
[°CDtd/°FDtd]
Min
Dewpoint distance measurement (only H1)
Temperature difference IR minus dewpoint max
current
min.
Max
aw[-]
Min
Surface moisture measurement (only H1)
Surface moisture max.
current
min.
Calculated from dewpoint, ambient air and
surface temperature
- 0.00 - 0.64: non-critical
- 0.65 - 0.80: poss. critical
- 0.81 - 1.00: critical
15 Displays the battery charge status.
16 Displayed if alarm is switched on.
17 Displays the selected emissivity.
18 Displayed if laser is switched on.
Connecting the thermocouple probe
1- Connect the connecting plug to the probe socket (6).
Switching the instrument on
1- Press (9).
- OR
- Press Trigger (4).
Switching the instrument off
1- Hold down (9) until the display goes off.
If no button is pressed for 2 minutes, the instrument switches off
automatically.
3
Carrying out the measurement
1 - Hold down Trigger (4).
2 - Release Trigger (4) to end the measurement.
3 - Move (7) up / down to change the reading display.
Making settings
1 - Press (7) to open the menu.
2 - Move and press (7) to select the menu item.
3 - Moving and pressing (7) applies the settings.
Setting the emissivity
Materials have various emissivities, i.e. they emit various amounts of
electromagnetic radiation. The emissivity of the instrument has a default
setting of 0.95. This is ideal for the measurement of non-metals (paper,
ceramic, gypsum, wood, paints and varnishes), plastics and foodstuffs.
1 - Press (11).
2 - For Customise manual and Customise auto,
move (7) right to enter the emissivity.
For Customise auto, please refer to the instruction manual.
3 - Press (7) to confirm the selected emissivity.
Creating a storage location and saving readings
1 - Press (10) to open the memory function.
2 - Select New Location.
3 - Move (7) up / down or right / left to name the storage location.
4 - Confirm storage with .
Measuring lens
(Ratio of distance: measuring range)
Depending on the distance of the measuring instrument from the measurement
object, a specific measuring range is recorded.
In italics = laser
Not in italics = measuring range
Managing the measurement data and other measurement options
Please download the free testo EasyClimate software for managing and archiving
your measurement data and for carrying out an online measurement.
You will find the link to download it here: www.testo.com/download-center
testo 835-H1
short instruction
www.testo.com
These brief instructions describe the basic operating steps. Please refer to
the instruction manual to find out how to handle the product safely and for
detailed information.

Other TESTO Thermometer manuals

TESTO 104-IR BT User manual

TESTO

TESTO 104-IR BT User manual

TESTO 915-2 User manual

TESTO

TESTO 915-2 User manual

TESTO 0560 8316 User manual

TESTO

TESTO 0560 8316 User manual

TESTO 104 User manual

TESTO

TESTO 104 User manual

TESTO 915i User manual

TESTO

TESTO 915i User manual

TESTO 105 User manual

TESTO

TESTO 105 User manual

TESTO 905-T1 User manual

TESTO

TESTO 905-T1 User manual

TESTO 922 User manual

TESTO

TESTO 922 User manual

TESTO 104-IR User manual

TESTO

TESTO 104-IR User manual

TESTO 830-T1 User manual

TESTO

TESTO 830-T1 User manual

TESTO 905-T1 User manual

TESTO

TESTO 905-T1 User manual

TESTO Ex-Pt 720 User manual

TESTO

TESTO Ex-Pt 720 User manual

TESTO 810 User manual

TESTO

TESTO 810 User manual

TESTO 735 User manual

TESTO

TESTO 735 User manual

TESTO 925 User manual

TESTO

TESTO 925 User manual

TESTO 0560 8351 User manual

TESTO

TESTO 0560 8351 User manual

TESTO 922 User manual

TESTO

TESTO 922 User manual

TESTO 845 User manual

TESTO

TESTO 845 User manual

TESTO 922 User manual

TESTO

TESTO 922 User manual

TESTO 826-T1 User manual

TESTO

TESTO 826-T1 User manual

TESTO TEO104 User manual

TESTO

TESTO TEO104 User manual

TESTO 835 User manual

TESTO

TESTO 835 User manual

TESTO 105 User manual

TESTO

TESTO 105 User manual

TESTO 825-T1 User manual

TESTO

TESTO 825-T1 User manual

Popular Thermometer manuals by other brands

Shinko IRT-100-TA instruction manual

Shinko

Shinko IRT-100-TA instruction manual

MABIS RediScan 18-535-000 instruction manual

MABIS

MABIS RediScan 18-535-000 instruction manual

Grundig MDI231 user manual

Grundig

Grundig MDI231 user manual

Hark HK0316 operating instructions

Hark

Hark HK0316 operating instructions

ADC Adtemp II 412 Use, care & maintenance

ADC

ADC Adtemp II 412 Use, care & maintenance

Microlife MT 1931 user manual

Microlife

Microlife MT 1931 user manual

Orava MT-330 instruction manual

Orava

Orava MT-330 instruction manual

Springfield 91049-1 instruction manual

Springfield

Springfield 91049-1 instruction manual

Maverick Industries ET-901B instruction manual

Maverick Industries

Maverick Industries ET-901B instruction manual

Martellato 50T004 Handbook of use and maintenance

Martellato

Martellato 50T004 Handbook of use and maintenance

Wahl HEAT-PROBER 2500/1370 quick start guide

Wahl

Wahl HEAT-PROBER 2500/1370 quick start guide

Textron GREENLEE TG-1000 instruction manual

Textron

Textron GREENLEE TG-1000 instruction manual

IROX HTG79 operating instructions

IROX

IROX HTG79 operating instructions

MarMonix MIT-367 user manual

MarMonix

MarMonix MIT-367 user manual

TFA 30.5021 operating instructions

TFA

TFA 30.5021 operating instructions

Klein Tools IR1KIT instruction manual

Klein Tools

Klein Tools IR1KIT instruction manual

ETI FoodSafe 803-900 operating instructions

ETI

ETI FoodSafe 803-900 operating instructions

Fine Offset Electronics WN30BN user manual

Fine Offset Electronics

Fine Offset Electronics WN30BN user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.