Topens MK1101 User manual

Swing Gate Opener
User’s Manual
Model:
VER 21a
C030009
MK1101 / MK1102
MK1301 / MK1302
MK1101M / MK1102M
MK1301M / MK1302M
MK1501M / MK1502M
★Please read and follow all warnings, precautions and instructions before
installation and use.
★
Never connect the solar panel to the control board directly to charge the battery.
★Periodic checks of the opener are required to ensure safe operation.
★
Save this manual.
Table of Contents
Safety Installation Information.......................................................................................................................... 1
Dual Gate Opener Parts List............................................................................................................................ 2
Single Gate Opener Parts List .........................................................................................................................3
Optional Accessories Parts List........................................................................................................................4
Tools Needed: .................................................................................................................................................. 4
Technical Specifications & Features................................................................................................................5
Dual Gate Overview......................................................................................................................................... 7
Single Gate Overview.......................................................................................................................................8
Preparation for Installation............................................................................................................................... 8
Install the Gate Opener on the Gate................................................................................................................9
Mounting of the Control Box...........................................................................................................................13
Connection of the Power Supply.................................................................................................................... 14
Connection of the Control Board.................................................................................................................... 15
Motor connection for PULL-TO-OPEN ...............................................................................................................16
Motor connection for PUSH-TO-OPEN ..............................................................................................................16
How to learn or erase the Remote.................................................................................................................17
Setting of the Control Board...........................................................................................................................18
Indicate Illustration on the Digital Display When Gate Opener is Running................................................... 20
Adjusting the Limit Switch.............................................................................................................................. 21
How to Operate.............................................................................................................................................. 21
Maintenance................................................................................................................................................... 21
Trouble Shooting............................................................................................................................................22
Quick-Setting Guide.......................................................................................................................................23
1
Safety Installation Information
1. READ and FOLLOW all instruction.
2. The gate opener is intended for use with Class I
vehicular swing gates.
Class I denotes a vehicular gate opener (or system)
dwellings, or a garage or parking area associated
therewith.
Install the gate opener only when the opener is
appropriate for the construction and the usage class of
the gate.
3. Gate opening system designers, installers and
users must take into account the possible hazards
associated with each individual application. Improperly
designed, installed or maintained systems can create
risks for the user as well as the bystander. Gate
system design and installation must reduce public
exposure to potential hazards. All exposed pinch
points must be eliminated or guarded.
4. A gate opener can create high levels of force
during normal operation. Therefore, safety features
must be incorporated into every installation. Specific
safety features include safety sensors.
5. The gate must be properly installed and work
freely in both directions prior to the installation of the
gate opener.
6. The gate must be installed in a location so that
enough clearance is provided between the gate and
adjacent structure when opening and closing to
reduce the risk of entrapment. Swinging gates shall
not open into public access areas.
7. The opener is intended for use only on gates used
for vehicles. Pedestrians must be supplied with a
separate access opening. The pedestrian access
opening shall be designed to promote pedestrian
usage. The pedestrian access shall be located such
that persons will not come in contact with the moving
vehicular gate.
8. Pedestrians should never cross the pathway of a
moving gate. The gate opener is not acceptable for
use on any pedestrian gate. Pedestrians must be
supplied with a separate pedestrian access.
9. For an installation utilizing non-contact sensors
(safety sensors), see product manual on the
placement of non-contact sensors (safety sensors) for
each type of application.
a. Care shall be exercised to reduce the risk of
nuisance tripping, such as when a vehicle trips the
safety sensor while the gate is still moving.
b. One or more non-contact sensors (safety sensors)
shall be located where the risk of entrapment of
obstruction exists, such as the perimeter reachable by
a moving gate or barrier.
10. Never mount any device that operates the gate
opener where the user can reach over, under, around
or through the gate to operate the controls. Controls
are to be placed at least 6’(1.8m) from any part of the
moving gate.
11. Controls intended to be used to reset an operator
after 2 sequential activations of the entrapment
protection device or devices must be located in the
line of sight of the gate, or easily accessible controls
shall have a security feature to prevent unauthorized
use. Never allow anyone to hang on or ride the gate
during the entire travel of the gate.
12. Each gate opener is provided with two safety
warning placards. The placards are to be installed on
the front and back of the gate where they are plainly
visible. The placards may be mounted using cable ties
through the four holes provided on each placard.
All warning signs and placards must be installed
where visible in the area of the gate.
2
13. To AVOID damaging gas, power, or other
underground utility lines, contact underground utility
locating companies BEFORE digging.
SAVE INSTRUCTION.
14. Do not permit children to play on or around the
gate and keep all controls out of their reach.
Dual Gate Opener Parts List
3
Single Gate Opener Parts List
4
Optional Accessories Parts List
Tools Needed:
·Power Drill ·Tape Measure ·Open End Wrenches - 14# &17# orAdjustable Wrenches
·Wire Strippers ·C-Clamps - small, medium, and large ·Level ·Hacksaw or Heavy Duty Bolt Cutters
·Phillips Screwdriver ·An extra person will be helpful
5
Technical Specifications & Features
Specifications
MK1101/1102
MK1101M/1102M
MK1301/1302
MK1301M/1302M
MK1501M/1502M
Input:
110V~120V/60Hz or 220~240V/50Hz
Motor voltage:
24VDC
Power:
50W each actuator
80W each actuator
100W each actuator
Current:
2A
3A
4A
Actuator speed:
20mm/s(0.8 in/s)
Max. actuator travel:
385mm(15.2 in)
485mm(19 in)
Ambient Temperature:
-22℃~ +55℃(-4°F to 122°F)
Protection class:
IP44
Gate Capacity of MK11
Gate Weight
300kg(660lbs)

NR
NR
NR
NR
NR
NR
250kg(550lbs))


NR
NR
NR
NR
NR
200kg(440lbs))



`
NR
NR
NR
150kg(330lbs)




NR
NR
NR
100kg(220lbs)





NR
NR
70kg(150lbs)






NR
50kg(110lbs)







1.5-2m(5-7')
2.5m(8')
3m(10')
3.5m(12')
4m(13')
5m(16')
5.5m(18')
Gate Length
Gate Capacity of MK13
Gate Weight
400kg(880lbs)

NR
NR
NR
NR
NR
NR
350kg(770lbs)


NR
NR
NR
NR
NR
300kg(660lbs)



NR
NR
NR
NR
250kg(550lbs)




NR
NR
NR
200kg(440lbs)





NR
NR
150kg(330lbs)






NR
100kg(220lbs)







1.5-2m(5-7')
2.5m(8')
3m(10')
3.5m(12')
4m(13')
5m(16')
5.5m(18')
Gate Length
6
Gate Capacity of MK15
Gate Weight
450kg(990lbs)


NR
NR
NR
NR
NR
NR
400kg(880lbs)



NR
NR
NR
NR
NR
350kg(770lbs)




NR
NR
NR
NR
300kg(660lbs)




NR
NR
NR
NR
200kg(440lbs)





NR
NR
NR
150kg(330lbs)






NR
NR
100kg(220lbs)








1.5-2m(5-7')
2.5m(8')
3m(10')
3.5m(12')
4m(13')
5m(16')
5.5m(18')
6m(20')
Gate Length
Features:
·Soft start and soft stop
·Emergency release key in case of power failure
·Dual/Single gate running mode
·Adjustable opening/closing interval between master and slave gate
·Stop in case of obstruction during gate opening.
·Reverse in case of obstruction during gate closing.
·Built in adjustable auto-close (0-99 seconds)
·Built in max. Motor running time (MRT) adjustable for multiple safety protection (1-50 seconds)
·Digital display indicates the running situation and setting menu
·Can be equipped with a wide range of accessories
·Reliable electromagnetism limit for easy adjustment
·Easy to install, and minimum maintenance requirement
7
Dual Gate Overview
8
Single Gate Overview
Preparation for Installation
There are two installation types for the gate opener, Pull-to-Open and Push-to-Open.
In the Push-to-Open installation, gate opens out from the property. A Push-To-Open Bracket (PSO part) is
required to be used for each gate.
The gate opener is mounted to the gate and to the gate post. Both round and square posts can be used
because the Post Brackets are curved. When mounting the Post Brackets, use bolts long enough to pass
through the entire post. M10 x 200 bolts are included. Concrete anchors are not provided.
When mounting the Post Brackets to wooden posts, a larger-size washer or metal plate should be used
between the bolts and the wooden post to ensure the stability of the fastening hardware. If the post is smaller
than 6" diameter or square, it should be made of metal and set in cement to ensure its stability.
NOTE: Ensure the gate does not open into public areas.
9
Install the Gate Opener on the Gate
The position of Post Bracket is very important. The following illustrations and tables are required to determine
the proper mounting position for the Post Bracket. The tables show the maximum opening angle of the gate for
a given A and B. For example, if A is 16cm and B is 14cm, the maximum opening angle of the gate is 110°
Pull-to-Open Installation —Gate in Closed position (Moving-Rod is extended)
10
Push-to-Open Installation —Gate in Closed position (Moving-Rod is retracted)
1. Insert the M10 x 30 bolt through the center hole of the post bracket and
post pivot bracket as shown. Place a ¢10 washer , ¢10 lock washer and
M10 nut on the bottom of the bolt and hand tighten.
2. Attach the gate bracket and post bracket assembly to the opener by
inserting a clevis pin. Secure the clevis pins using the hairpin clips.
3. Open the release hole plug on the top of the gate opener, insert the release
key, and turn the key 90°clockwise. This releases the motor and allows the
push-pull rod to be manually extended and retracted. To restore normal
operation, turn the key 90°counterclockwise.
4. With the opener fully retracted and with the gate in the fully open
position (for Pull-to-Open installation) or fully closed position (for
Push-to-Open installation), place the gate opener with the Post Bracket
Assembly and Gate Bracket on the gate post and the gate. Position the Post
Bracket Assembly and Gate Bracket so that the gate opener is level. While
holding the gate opener in the level position, temporarily secure it with two
C-clamps.
11
5. Make sure that there is a minimum clearance of 2.5cm between the gate and the opener and that the opener
and the Post Pivot Bracket are not binding in both the gate-open and gate-closed positions. If there is not at
least 2.5cm of clearance or if the opener and the Post Pivot Bracket are binding, rotate the Post Pivot Bracket
and/or move the Post Bracket Assembly to obtain the minimum clearance and eliminate the binding. When the
minimum clearance has been obtained and any binding has been eliminated, place the M8 x 30 bolt through the
aligned holes in the Post Bracket and the Post Pivot Bracket.
12
6. Sign the bolt-hole point on the gate bracket and gate. Do this by placing a
punch or a sign in the middle of each bolt slot on the post bracket assemblies
and the gate bracket. It allows slight adjustments to the post bracket. Then
remove the post bracket and gate bracket by taking off the C-clamps.
7. Drill 10.5 mm diameter holes through the post and the gate at the marked
locations.
8. Attach the post bracket assemblies to the gate posts by inserting M10 x
200 bolts through each post bracket assembly and the drilled holes in the
gate post. Fasten each bolt with one ¢10 washer, one ¢10 lock washer,
and one ¢10 nut.
9. Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the gate brackets and the
drilled holes in the gates. Fasten each bolt with one ¢10 lock washer, and one ¢10 nut.
13
10. Cut off any part of the bolts that extend beyond the tightened nuts.
11. With the gate opener fully retracted and with the gate in the fully open position (for Pull-to-Open installation)
or fully closed position (for Push-to-Open installation), attach the gate opener to the Post BracketAssembly and
the Gate Bracket by inserting a clevis pin through the gate opener and the Post Pivot Bracket and another clevis
pin through the gate opener and the Gate Bracket. Secure each clevis pin with a hairpin clip.
12. Open the release hole plug on the top of the gate opener, insert the release key, and turn the key 90°
counterclockwise. This restores normal operation.
NOTE: The setting of the PULL/PUSH TO OPEN of the control board should be in accordance with the
installation.
Mounting of the Control Box
1.To install the control box use the deck screws (not provided).
Even though the control box is waterproof designed, for safety reason and
a longer service life, it is recommended to install the control box inside a
secure surface and at least 100 cm (40 inches) above the ground to avoid
being flooded or buried under snow.
2.Insert the power cable and cable of the first gate opener through the front
strain relief and into the control box by loosening the strain relief screw
located in the leftmost of outside bottom of the control box and feeding the
cables into the control box. Check the length of cables is long enough to
their respective terminal block in control box.
14
CAUTION: Install the Control Box in a well ventilated place protected against rain and
sunlight.
3.Insert the cable of the second gate opener and alarm lamp cables into the control
box through middle strain relief. Then repeat step 2.
4. Insert other cables into the control box through rightmost strain relief. Then repeat
step
NOTE: Only motor cables (1.5m length) are provided. Other cables are subject to site
installation requirement and not provided.
CAUTION: Make sure the cable outlet hole in the Control Box is always down during
installation so as to drain off the water.
Connection of the Power Supply
WARNING: NEVER connect the gate opener to the power outlet before all the installations have
been done.
The live line and the neutral line should be connected to the power input terminals as the below photo. No
matter the polarity. The wire (not provided) size should be at least 0.75mm2 (18AWG) which is intended to
connect the power supply.
15
Connection of the Control Board
16
Motor connection for PULL-TO-OPEN
Actuator 1
Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The red wire
should be inserted into the “MOTOR1+” terminal, the black wire into “MOTOR1-“, the blue wire into ULT1, the
green wire into COM, and the yellow wire into DLT1 terminal.
Actuator 2
Similar as the connection of Actuator 1, insert the stripped cable wires into the appropriate terminals on the
opener terminals block. The red wire should be inserted into the MOTOR2+ terminal, the black wire into
MOTOR2-, the blue wire into ULT2, the green wire into COM, and the yellow wire into DLT2 terminal.
NOTE: It is recommended that Gate Opener 1 is installed in the Master Gate, and Gate Opener 2 is installed in
the Slave Gate.
Motor connection for PUSH-TO-OPEN
The motors’ power wires and limit wires connection by “Push to
Open” is different from the connection by “Pull to Open”. So motor
1 and motor 2 wires should be connected to the control box as the
instruction on the right. The black wire should be inserted into the
Motor+ terminal, the red wire should be inserted into the Motor-
terminal, the yellow wire into ULT1 terminal, the blue wire into
DLT1 terminal and the green wire is still into COM terminal.
Alarm Lamp (optional)
The red wire of the alarm lamp should be inserted into either LAMP
(#11) terminal, the white wire into the other one (#12).
Back-up Battery (optional)
The “24V+” of the battery should be wired to the BAT+ (#13) terminal, “24V-” should be wired to “BAT-” (#14)
terminal.
Recommend strongly to use the controller LM118 (WA4004
)
to connect Battery with battery’s Terminal
of control board if the battery is used as the primary power supply in system (such as SOL PLUS KIT).
Please refer to the user manual of control LM118
(
WA4004
)
separated.
Photocell Beam System (PBS) (optional)
Use a 2-core cable to connect the “- ~”terminal of the photocell’s emitter to the “14” terminal, the “+ ~”terminal
to the “9” terminal.Also the “- ~”and “+ ~”terminals of the photocell’s receiver should be connected to the “14”
and “9”terminals in parallel.
Use another 2-core cable to connect the “COM”terminal of the receiver to the “17”terminal, the “NC”terminal
to the “18”terminal.
Push Button (optional)
The push button should be wired to the “19” and “20” terminals. The gate operator works alternately by pushing
the button (open-stop-close-stop-open).
17
WARNING: Activate the opener only when gate is in full view, free of obstruction and properly adjusted. No
one should enter or leave gate area while gate is in motion. Do not allow children to operate push button or
remote. Do not allow children to play near the door.
Your swing gate opener receiver and remote control transmitter are set to a matching code. If you purchase
additional remote controls, the gate opener must be programmed to accept the new remote code.
Caution: If you lose one of any remote control, please
learn all other remote controls to have a new code for
Loop Detector (optional)
First insert the LOOP DETECTOR BOARD into the CONTROL BOARD, and then connect the LOOP
DETECTOR to the control board. Detailed instruction please refers to the manual instruction of LOOP
DETECTOR separated.
Exit Wand (optional)
Please refers to the manual instruction of EXIT WAND separated.
Electric Lock (optional)
The electric lock should be wired to the “LOCK” terminal.
External Receiver (optional)
The BROWN wire of the external receiver should be connected into the “19” terminal.
The BLACK wire of the external receiver should be connected into the “20” terminal.
The RED wire of the external receiver should be connected into the “9” terminal.
Wired Keypad (24VDC) (optional)
The RED wire of the wired keypad should be connected into the “9” terminal.
The BLACK wire of the wired keypad should be connected into the “14” terminal.
The WHITE wire of the wired keypad should be connected into the “19” terminal.
The BLUE wire of the wired keypad should be connected into the “20” terminal.
Solar Panel(optional)
Please refer to the manual instruction of solar panel and controller (LM118) separated.
How to learn or erase the Remote
Learn the remote
Press and release the learn button, the LED will display “Ln”, then press the key in the remote twice in 2
seconds, the LED will flash “Ln” for 4 seconds then back to “- -”. Now the remote has been learnt successfully.
Erase all the remote codes
Press and hold the learn button until the LED display “dL”,
release the button and the LED will be back to “- -”. Now
all remote codes have been erased..
18
Setting of the Control Board
1. Check again for completed and correct assembly of your swing gate opener
and gate. Plug the Power Grounded Cord into the nearestAC outlet. The Digital
Display on the Control Board will flash with “- -”. The unit is in standby.
2. Single/Dual Gate Set
Press and hold the “FUNC”button for more than 4 seconds. The Digital Display
will indicate“P1”. Gate opener is on the SINGLE/DUAL Gate setting. Press the
“INC”and “DEC”buttons respectively to following modes:
“01”shown in Digital Display, it is Single Actuator 1 (Gate 1) mode. “10”shown
in Digital Display, it is SingleActuator 2 (Gate 2) mode. “11”shown in Digital Display, it is Dual actuator mode.
Press the “FUNC”button to store the data when the single or dual gate is chosen. The Digital Display will
indicate “P2”. Now single/dual gate set is finished.
(Factory set is “11”)
3. Master/Slave Gate Set
When Digital Display indicates “P2”, the gate opener is on the Master/Slave Gate Setting. Press the “INC” and
“DEC” Buttons respectively to follow modes:
“01”shown in Digital Display, which means Gate Opener 1 (right-hand side) as Master one
“10”shown in Digital Display, which means Gate Opener 2 (left-hand side) as Master one
Press the “FUNC”button to store the data when the master/slave gate is chosen. The Digital Display will
indicate “P3”. Now Master/Slave Gate Set is finished.
(Factory set is “01”)
4. Set the Open Interval between Master and Slave Gate
When the Digital Display indicates “P3”, the gate opener is on the Open Interval between Master/Slave Gate
Setting.
The open interval can be adjusted by pressing the “INC” and “DEC” Buttons respectively. The Digital Display
will show “0”-“9”, which indicates the interval time “0”means the Master and Slave gates open simultaneously.
“1”means the Master Gate starts to open 1 second before Slave gate starts to open. Max. open interval is 9
seconds. Each time you press and release the “INC”button, the figure increases by 1, and the Master gate
starts to open 1 more second earlier. Each time you press and release the “DEC”button, the figure decreases
by 1, and the interval decreases by 1 second.
(Factory set is 3 seconds)
Press the “FUNC”button to store the data when the open interval is set. The Digital Display will indicate “P4”.
Now Open Interval Set is finished.
5. Set the Close Interval between Master and Slave Gate
When the Digital Display indicates “P4”, the gate opener is on the Close Interval between Master/Slave Gate
Setting.
The close interval can be adjusted by pressing the “INC” and “DEC” buttons respectively. The Digital Display
will show “0”-“9”, which indicates the interval time ”0”means the Master and Slave gates open
simultaneously. ”1”means the Slave Gate starts to close 1 second before Master gate starts to close. Maximum
close interval is 9 seconds. Each time you press and release the “INC”button, the figure increases by 1, and the
Slave gate starts to close 1 more second earlier. Each time you press and release the “DEC”button, the figure
decreases by 1, and the interval decreases by 1 second.
(Factory set is 3 seconds)
Press the “FUNC”button to store the data when the close interval is set. The Digital Display will indicate “P5”.
Now Close Interval Set is finished.
6. Adjust the Obstruction Sensitivity/Stall Force

This manual suits for next models

9

Other Topens Gate Opener manuals

Topens RK2600 User manual

Topens

Topens RK2600 User manual

Topens HLR01 User manual

Topens

Topens HLR01 User manual

Topens CK2600 User manual

Topens

Topens CK2600 User manual

Topens DKC500 User manual

Topens

Topens DKC500 User manual

Topens JY9132 User manual

Topens

Topens JY9132 User manual

Topens TEW3 User manual

Topens

Topens TEW3 User manual

Topens AT1202 User manual

Topens

Topens AT1202 User manual

Topens Casar MT8012 User manual

Topens

Topens Casar MT8012 User manual

Topens DKC2000 User manual

Topens

Topens DKC2000 User manual

Topens KD902 User manual

Topens

Topens KD902 User manual

Topens CK700 User manual

Topens

Topens CK700 User manual

Topens AT6131 User manual

Topens

Topens AT6131 User manual

Topens CK500 User manual

Topens

Topens CK500 User manual

Topens CF800 User manual

Topens

Topens CF800 User manual

Topens LC1100 User manual

Topens

Topens LC1100 User manual

Topens A3132 User manual

Topens

Topens A3132 User manual

Topens RK700 User manual

Topens

Topens RK700 User manual

Topens CK1200 User manual

Topens

Topens CK1200 User manual

Topens RK990 User manual

Topens

Topens RK990 User manual

Topens A3131 User manual

Topens

Topens A3131 User manual

Topens CASAR HJ4021 User manual

Topens

Topens CASAR HJ4021 User manual

Topens BK800 User manual

Topens

Topens BK800 User manual

Topens TC148 User manual

Topens

Topens TC148 User manual

Topens AT602 User manual

Topens

Topens AT602 User manual

Popular Gate Opener manuals by other brands

Casanoov TANKER B350 instruction manual

Casanoov

Casanoov TANKER B350 instruction manual

CAME F1000 installation manual

CAME

CAME F1000 installation manual

SOMFY 3S io user manual

SOMFY

SOMFY 3S io user manual

BFT E5 BT A18 Installation and user manual

BFT

BFT E5 BT A18 Installation and user manual

RIB BOSS 230V MASTER DX manual

RIB

RIB BOSS 230V MASTER DX manual

Linear SWG installation guide

Linear

Linear SWG installation guide

US Automatic PATRIOT RSL Installation & owner's manual

US Automatic

US Automatic PATRIOT RSL Installation & owner's manual

US Automatic PATRIOT RSL Installation & owner's manual

US Automatic

US Automatic PATRIOT RSL Installation & owner's manual

Keyautomation REVO Instructions and warnings for installation and use

Keyautomation

Keyautomation REVO Instructions and warnings for installation and use

GiBiDi BL240 Instructions for installation

GiBiDi

GiBiDi BL240 Instructions for installation

HySecurity HYNET SFP 4/1 installation manual

HySecurity

HySecurity HYNET SFP 4/1 installation manual

Keyautomation SUN Series Instructions and warnings for installation and use

Keyautomation

Keyautomation SUN Series Instructions and warnings for installation and use

Entrematic Ditec FACIL Technical manual

Entrematic

Entrematic Ditec FACIL Technical manual

Power Master rsw installation manual

Power Master

Power Master rsw installation manual

Keyautomation CT102 24 Instructions and warnings for installation and use

Keyautomation

Keyautomation CT102 24 Instructions and warnings for installation and use

Keyautomation STAR3024 Instructions and warnings for installation and use

Keyautomation

Keyautomation STAR3024 Instructions and warnings for installation and use

HySecurity SwingSmart DC 20 Installation and reference manual

HySecurity

HySecurity SwingSmart DC 20 Installation and reference manual

GiBiDi AUTOBOX 3000 Instructions for installation

GiBiDi

GiBiDi AUTOBOX 3000 Instructions for installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.