manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tyco Electronics
  6. •
  7. Cables And Connectors
  8. •
  9. Tyco Electronics 1-1718624-1 User manual

Tyco Electronics 1-1718624-1 User manual

Other Tyco Electronics Cables And Connectors manuals

Tyco Electronics LightCrimp Plus LC User manual

Tyco Electronics

Tyco Electronics LightCrimp Plus LC User manual

Tyco Electronics 58449-1 User manual

Tyco Electronics

Tyco Electronics 58449-1 User manual

Tyco Electronics CPC 45 Series User manual

Tyco Electronics

Tyco Electronics CPC 45 Series User manual

Tyco Electronics 16Pos.Plug Housing Reference guide

Tyco Electronics

Tyco Electronics 16Pos.Plug Housing Reference guide

Tyco Electronics Raychem C25-21 User manual

Tyco Electronics

Tyco Electronics Raychem C25-21 User manual

Tyco Electronics AMP NETCONNECT AMPTRAC User manual

Tyco Electronics

Tyco Electronics AMP NETCONNECT AMPTRAC User manual

Tyco Electronics LightCrimp Plus ST User manual

Tyco Electronics

Tyco Electronics LightCrimp Plus ST User manual

Tyco Electronics 408-10254 User manual

Tyco Electronics

Tyco Electronics 408-10254 User manual

Tyco Electronics ACO Single Port Kits User manual

Tyco Electronics

Tyco Electronics ACO Single Port Kits User manual

Tyco Electronics AMP 1804018-1 Assembly instructions

Tyco Electronics

Tyco Electronics AMP 1804018-1 Assembly instructions

Tyco Electronics 1362990-1 User manual

Tyco Electronics

Tyco Electronics 1362990-1 User manual

Tyco Electronics AMP NETCONNECT MRJ21 User manual

Tyco Electronics

Tyco Electronics AMP NETCONNECT MRJ21 User manual

Tyco Electronics Raychem HVS-T-1580E-S Series User manual

Tyco Electronics

Tyco Electronics Raychem HVS-T-1580E-S Series User manual

Tyco Electronics SOLARLOK 4-1394462-6 User manual

Tyco Electronics

Tyco Electronics SOLARLOK 4-1394462-6 User manual

Tyco Electronics GPRA1 User manual

Tyco Electronics

Tyco Electronics GPRA1 User manual

Tyco Electronics AMP User manual

Tyco Electronics

Tyco Electronics AMP User manual

Tyco Electronics AMP NETCONNECT MRJ21 User manual

Tyco Electronics

Tyco Electronics AMP NETCONNECT MRJ21 User manual

Tyco Electronics 58062-1 User manual

Tyco Electronics

Tyco Electronics 58062-1 User manual

Tyco Electronics LightCrimp Plus LC User manual

Tyco Electronics

Tyco Electronics LightCrimp Plus LC User manual

Tyco Electronics AMP Series User manual

Tyco Electronics

Tyco Electronics AMP Series User manual

Tyco Electronics D2950 User manual

Tyco Electronics

Tyco Electronics D2950 User manual

Tyco Electronics RECORDsplice User manual

Tyco Electronics

Tyco Electronics RECORDsplice User manual

Popular Cables And Connectors manuals by other brands

StarTech.com ST124HD20 quick start guide

StarTech.com

StarTech.com ST124HD20 quick start guide

Philips SWV4543S/10 Features

Philips

Philips SWV4543S/10 Features

Larson Electronics 10-50C instruction manual

Larson Electronics

Larson Electronics 10-50C instruction manual

Grip MEK-PM Assembly and operating manual

Grip

Grip MEK-PM Assembly and operating manual

Ultra Products Travel Pack #3 ULT31436 Specifications

Ultra Products

Ultra Products Travel Pack #3 ULT31436 Specifications

Surpass QCH-F Operation manual

Surpass

Surpass QCH-F Operation manual

Philips SWA6310 Specifications

Philips

Philips SWA6310 Specifications

StarTech.com CRJ4550PK quick start guide

StarTech.com

StarTech.com CRJ4550PK quick start guide

Nohau EMUL-IP2K-PC user guide

Nohau

Nohau EMUL-IP2K-PC user guide

Foxun SX-SP144E-HD4K2K operating instructions

Foxun

Foxun SX-SP144E-HD4K2K operating instructions

Philips SWA3305W Specifications

Philips

Philips SWA3305W Specifications

opticis Stretch DVIM1-1P0x user manual

opticis

opticis Stretch DVIM1-1P0x user manual

Volkswagen VAS 6558A operating manual

Volkswagen

Volkswagen VAS 6558A operating manual

NEXIBO N-13 user manual

NEXIBO

NEXIBO N-13 user manual

CYP PU-1H3HBTL Operation manual

CYP

CYP PU-1H3HBTL Operation manual

Allen-Bradley 1784-u2dhp installation instructions

Allen-Bradley

Allen-Bradley 1784-u2dhp installation instructions

Global Caché Flex Link Blaster quick start

Global Caché

Global Caché Flex Link Blaster quick start

Hauppauge USB-Live2 Quick installation guide

Hauppauge

Hauppauge USB-Live2 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.


Recommandations générales d’utilisation
Instruction sheet
411-15734
20-Aug-07, Rev. A
Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP


1 to 15Tyco Electronics France Sas
B.P. 30039, 95301 CERGY-PONTOISE Cedex
©2002 Tyco Electronics Corporation
All International Rights Reserved
(Tous droits réservés) LOC F
Ce document est sujet à modifications. Contacter Tyco Electronics pour identifier la dernière révision et en
obtenir une copie. Personnel Tyco Electronics : consultez la base de données Startec.
This document, managed by Tyco Electronics France, is archived in the Startec database.
A printout cannot be considered as a controlled document.


1INTRODUCTION - Introduction
2REFERENCES DES PRODUITS – Part Numbers
 
  
 
   
3SERTISSAGE DES CONTACTS – Crimping of contacts!
4INSERTION DES CONTACTS – Contact insertion!
 "#!
 $%
 &'  ()' ))*
5DEMONTAGE D’UN CONTACT – Extraction of contact+
 ' ' +
 ,-)+
6ACCOUPLEMENT DES CONNECTEURS – Mating of connectors
7DESACCOUPLEMENT DES CONNECTEURS – Unmating of connectors
8RECOMMANDATION GENERALE D’UTILISATION DES CONTACTS-
Instruction sheet for use of terminal
9RECOMMANDATION GENERALE D’UTILISATION DES CONNECTEURS-
Instruction sheet for use of connector..
10PRECONISATION DU CONTROLE ELECTRIQUE PAR PUSH TEST-
Instruction sheet for electrical control by puch test.
11PLAN DE L’OUTIL DE DEMONTAGE DU VERROU SECONDAIRE
Drawing of extraction tool




Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 2 to 15


1 - INTRODUCTION 1- INTRODUCTION
Cette spécification décrit les recommandations
d’utilisation du connecteur 2 voies 2.8 MCP. Le
connecteur est constitué d’un porte-clips, un
verrou secondaire, un joint interfacial et un CPA
qui assure une bonne connexion, (Connector
Positioning Assurance)
La conception des connecteurs permet de réduire
au minimum les risques d’un mauvais verrouillage
des contacts dans les boîtiers et les erreurs de
montage lors de la fabrication et de la mise en
œuvre des faisceaux.
Néanmoins, il faut respecter certaines
recommandations d’utilisation et de stockage pour
que la fabrication et le montage des faisceaux se
fassent correctement.
This specification describes recommendations of
use of 2.8 MCP 2 ways connector. The connector
is composed of a receptacle part a secondary
lock, a sealing The receptacle part has a mating
help slide. Mating assurance is guaranteed by a
CPA (Connector Positioning Assurance)
Design of connectors reduces the risk of wrong
mating of a contact in housing and mating error
during making and use of harness.
Some recommendations must be respected for
the use and the storage of connectors to make
sure that assembly and use of harness is correct.


Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 3 to 15


2 REFERENCES DES PRODUITS – PART NUMBERS
REFERENCES TYCO
TYCO PART NUMBER DESIGNATION
DESCRIPTION
1-1718624-1 PORTE CLIP 2 VOIES 2.8 MCP
Receptacle Housing 2 WAYS 2.8 MCP

DESIGNATION
DESCRIPTION
REPERE
ITEM
COULEUR
COLOR
Porte-clips 2 voies
2 ways receptacle part 1 NOIR
BLACK
Verrou secondaire
Secondary lock 2 NOIR
BLACK
Joint Interfacial
Sealing 3 NATUREL
NATURAL
CPA
Cpa 4 ROUGE
RED
SPECIFICATION PRODUIT
PRODUCT SPECIFICATION DESIGNATION
DESCRIPTION
108-18981 PORTE CLIP 2 VOIES
RECEPTACLE HOUSING 2 WAYS
108-18513-1 CLIP MCP 2.8
2.8 MCP FEMALE TERMINAL
108-18509-0 CLIP SENSOR 2.8
2.8 SENSOR FEMALE TERMINAL

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 4 to 15


2.1 Détrompage – Coding (keying)

Le Porte-clips est détrompé visuellement (couleur)
et mécaniquement.
2.2 Matière – Raw Material
Receptacle parts have visual (color) and
mechanical coding (keying) device.
COMPOSANT
Component MATIERE
Raw Material
PORTE CLIP 2 VOIES
2 ways receptacle part PA66 CHARGE FIBRE DE VERRE
PA66 glass fiber reinforced
VERROU SECONDAIRE
Secondary lock PA66 CHARGE FIBRE DE VERRE
PA66 glass fiber reinforced
JOINT INTERFACIAL
Sealing SILICONE
Silicone ruber
CPA
Cpa PA66 CHARGE FIBRE DE VERRE
PA66 glass fiber reinforced

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 5 to 15


2.3 Contacts - Contacts
Les contacts utilisés sont du type MCP ou
SENSOR.
Used contacts are MCP or SENSOR family type.
REFERENCE TYCO
TYCO PART NUMBER DESIGNATION
DESCRIPTION
1-0968855-1 CLIP MCP 2.8 0.5 à1.0 mm2
2.8 MCP RECEPTACLE 0.5 to 1.0 SQMM
1-0968857-1 CLIP MCP 2.8 1.5 à 2.5 mm2
2.8 MCP RECEPTACLE 1.5 to 2.5 SQMM
967542-1 CLIP SENSOR 2.8 0.5 à1.0 mm2
2.8 SENSOR RECEPTACLE 0.5 to 1.0 SQMM
967543-1 CLIP SENSOR 2.8 1.5 à 2.5 mm2
2.8 SENSOR RECEPTACLE 1.5 to 2.5 SQMM
REFERENCE TYCO
TYCO PART NUMBER DESIGNATION
DESCRIPTION GAMME DE FIL
WIRE RANGE
828904-1 JOINT SUR FIL
WIRE SEAL DIA AVEC ISOLANT 1.2 à 2.1mm
DIA WITH INSULATER 1.2 to 2.1mm
828905-1 JOINT SUR FIL
WIRE SEAL DIA AVEC ISOLANT 2.2 à 3mm
DIA WITH INSULATER 2.2 to 3mm
2.4 Conducteurs - Wires
Les contacts admettent les conducteurs suivant
définition des plans des contacts concernés. Contacts can admit wires regarding definitions
described in Tyco contact customer drawing.

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 6 to 15


3 SERTISSAGE DES CONTACTS – CRIMPING OF CONTACTS
Le sertissage des contacts doit être effectué en
utilisant les outillages TYCO en suivant les
procédures définies dans les spécifications de
sertissage TYCO et dans le plan client du contact
concerné.
Crimping of contacts must be done using Tyco
crimping tools respecting Tyco crimping
specification and Tyco contact customer drawing.
SPECIFICATION DE SERTISSAGE
APPLICATION SPECIFICATION DESIGNATION
DESCRIPTION
114-18148-1 CLIP MCP 2.8
MCP 2.8 TERMINAL
114-18144-0 CLIP SENSOR 2.8
MCP 2.8 TERMINAL
4 INSERTION DES CONTACTS – CONTACT INSERTION
4.1 Vérification - Control
Il est important de s’assurer que les contacts ne
sont pas déformés avant insertion car cela peut
être la cause d’un mauvais fonctionnement de la
connexion. Les spécifications de sertissage et les
plans des contacts donnent les déformations
acceptables des fûts de sertissage.
Confirm that the contacts are not deformed.
Deformations may cause damage or reduction of
performance of the connection. Crimping
specification of the contact and Tyco contact
customer drawings describe deformation limits
allowed for contacts.

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 7 to 15


4.2 Insertion des contacts – Contact insertion
S'assurer que le verrou secondaire est en position
pré-verrouillée avant d’insérer les contacts. Si ce
n’est pas le cas ouvrir le verrou suivant les
recommandations du paragraphe 5.1.
Si le boîtier a subi une chute, il peut être
endommagé. Ne pas utiliser le produit.
Le contact est polarisé. Il faut donc l'orienter
correctement avant de l'insérer dans le boîtier.
Le porte clip comporte 2 alvéoles en une rangée
numérotées 1 & 2.
Insérer les contacts dans le boitier jusqu’au
verrouillage primaire.
Il se verrouille grâce à deux lances en produisant
un "clic" tactile et audible. Enfin, le verrouillage
doit être vérifié en tirant légèrement (20N max)
sur le fil. Vérifier que le contact ne ressort pas de
la cavité.
Confirm that secondary lock is in preset position If
secondary lock is not in preset position, it must be
reworked using 5.1 paragraph instructions.
If receptacle or tab part falls down before use, it
may be damaged. Do not use the product.
The contact is polarized. It must be inserted with
good orientation regarding the housing.
The receptacle housing has 2 cavities on 1 row
numbered 1 & 2.
Insert the terminal in the receptacle housing until
the primary locking.
Contact locks in the cavity thanks to 2 lances with
a ‘clic’ tactile and audible sensation. Correct
locking of the contact must be checked by pulling
the contact lightly (20N max). Make sure the
contact can’t be withdrawn.




VERROU SECONDAIRE EN POSITION PRE-
VERROUILLE
SECONDARY LOCK IN PRESET POSITION
VERROU SECONDAIRE EN POSITION -
VERROUILLE
SECONDARY LOCK IN POSITION


Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 8 to 15






NOT OK
MAUVAISE ORIENTATION
BAD ORIENTATION



CLIP REVERSIBLE A 180°
RECEPTABLE TERMINAL REVERSIBLE AT
180°
DIRECTION D’INSERTION
INSERTION DIRECTION
CLIC
1

2
DIRECTION DE CONTROLE
CHECKING DIRECTION

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 9 to 15


4.3 Activation du double verrouillage – Secondary lock activation
Une fois que tous les contacts sont insérés dans
le boîtier, il faut activer le double-verrouillage en
appuyant suffisamment fort sur le verrou
secondaire. La course en rotation du verrou
secondaire est de 15 dgr En cas de non respect
de la condition d’effort et de déplacement
(position finale) cela signifie qu’au moins un
contact est mal inséré.
Once all contacts are inserted in housing,
secondary lock must put in final lock position by
pushing on the secondary lock. The travel of
secondary lock is 15 dgr. If force and final lock
position is not respected, it means that at least
one contact is not correctly inserted.
DIRECTION DU VERROUILLAGE
DIRECTION OF LOCKING LANCE






SURFACES PARALLELES
PARALLEL AREAS
LES CONTACTS SONT BIEN INSERES
TERMINALS ARE CORRECTLY
INSERTED

Porte clip 2 VOIES 2.8 MCP
Receptacle Housing 2 WAY 2.8 MCP 411-15734

Rev. A 10 to 15


5 DEMONTAGE D’UN CONTACT – EXTRACTION OF CONTACT
5.1 Désactivation du verrou secondaire – unlocking of secondary lock

Désactiver le verrou secondaire à l’aide d’un outil
spécifique. La course du verrou secondaire et de
15 dgr.
Unlock the secondary locking device by tool
specific. The travel of secondary lock Is 15 dgr.
5.2 Extraction des clips – extract the contact
Introduire l’outil de démontage (réf 1-1579007-6)
des clips dans le boitier en maintenant le fil à
l’arrière du contact. Lorsque l’outil est en butée
sur les linguets de verrouillage du contact dans
l’alvéole, tirer sur le fil pour extraire le contact.
Introduce extraction tool (number 1-1579007-6) of
contacts defined on the front side of connector in
the cavity. Push the tool in the housing,
maintaining the wire at the end of contact. When
tool is stopped on the locking lance of contact in
the cavity and the lance are deflected, pull on the
wire to extract the contact
1
TIRER SUR LE FIL
POUR EXTRAIRE
LE CONTACT ;
PULL ON THE WIRE
TO EXTRACT THE
CONTACT

DIRECTION
D’INSERTION DE
L’OUTIL DE
DEMONTAGE DES
CONTACTS
CONTACT
EXTRACTION TOOL
INSERTION
DIRECTION

DIRECTION D’INSERTION POUR DESACTIVER LE
VERROU SECONDAIRE
EXTRACTION DIRECTION FOR SECONDARY LOCK IN