826
Specifically:
A MAXIMUM OF 400 DEVICES CAN BE CONNECTED IN A
SYSTEM.
NOTE: Here,theterm device isusedto designateanyitemconnected
to thedataline,and thus includesfour-port decoders, entrance
modules, powersupply units, guard door switchboard station,
digitizers and so forth. It doesnot includeapartment station
doorphonesand videodoorphones.
Thus, asdoorphonesand videodoorphonesarenot includedinthetotal:
THE MAXIMUM NUMBEROF SYSTEM USERS IS FAR
ABOVE 400.
SYSTEM ACTIVATION
How activation isaccomplishedisfundamental to theinstallation’s
success. If thesystemincludesseveral risercables, eachwith its own
secondaryentrance module,proceedinsuccessivestepsasfollows:
•Separateeachrisercable so thatitisindependent of theothers,
disconnectingtheinputterminalblocksfromthesecondaryentrance
panels.
•Supply power, program, and checktheoperation of eachrisercable
inturn.
•ONLY atthispoint, connecttherisercablesto eachotherand to the
mainentrance panels.
•Checktheoperation of thecompletesystem.
Whetheryouaredealing withasingle risercableinacomplexsystem, or
must activateasimplersystem, thefollowing stepsmust beperformed:
•Preliminarycheckswith systemoff
•Activation
•Programming
•Systemoperation checks
PRELIMINARY CHECKS WITHSYSTEM OFF
Upon completing installation and before supplying powerto the
system, proceedasdescribedbelow:
1)Checkthatthereareno short circuits inthe5risercable wires.
2)Ensurethatall entrance panelsarecorrectly setupfor thetype
of apartment station doorphonesused(i.e., electronic call tone
or conventional buzzersignaling types),checking thatrisercable
wire1 isconnectedto speakerunitterminal “1A”for electronic
doorphonesor terminal “l”for conventional doorphones.
3) Checkthatthejumperon all decoders 826/23and/or 826/14is
inposition “E” for electronic call tonesignaling doorphonesor in
position “R” for conventional buzzerdoorphones.
4)If digitizers 826/16 or special servicesdigitizers 826/54areused,
ensurethatthejumpers arecorrectly positionedfor thetype of
service to beperformed(see theassociatedmanual).
5) Checktheconnectiononpowersupplyunits(826/25)withparticular
care: - input voltagemust bethatprovidedbymains (110/230/240
VAC).
•Systemsupply wiresmust beconnectedto terminals“+ 24”and
“-24”,taking careto ensurethatpolarityiscorrect.
•Terminal “D” mustbeconnectedto thedataline.
ACTIVATION
1)Beforeturning on voltageto thepowersupply unit, removethe
fusebypulling out theassociateholder.
2)Checkthattheyellow systemLED LIisoff, confirming thatthe
systemisnot energizedfrom othersources.
3) Turn on mains voltageWITHOUTinstalling thefuse.
4)Install thefuseinthepowersupply unit:thepowersupply LED LA
shouldturn redfor approximately 5seconds (re- initialization),and
thenturn greento indicatethatthesystemisbeing suppliedat24V.
5) Checkthattheseconditions aremaintainedfor atleast 1 minute
(i.e., makesurethatLED LAdoesNOTturn redagain).
PROGRAMMING
1)Programming must becarriedout first on the“calling”devices,
or inotherwords on theentrance modulesand guard door
switchboard station. Alwaysrecord all programming dataon the
memorandum label providedfor thispurpose.Rememberthat
systeminstallation TYPE(1 1 21 3) must beprogrammedon all
calling devices, and must bethesameon all of them(decoders do
not needto beprogrammedfor installation type).
2)Thenproceedto programthedecoders. Decoderprogramming can
becarriedout using oneof thethree methods illustratedinthe
decodermanual.Rememberto writedown thecodesprogrammedin
thedecoders on thememorandum labelsprovidedfor thispurpose.
3) Programtheguard door switchboard station, ifprovided.
4)Anyelectronic directoriesinthesystemmust beprogrammedlast.
SYSTEM OPERATION CHECKS
Whetheryou aredealing with asingle - and appropriately isolated- riser
cable inacomplexsystem, or must activateasimple systemwith only
onerisercable,carryout thefollowing checksintheorderindicated.
NOTE:
ALL PARTS OF THE SYSTEM MUST BE CHECKED,
ensuring that ALL envisagedfunctions operate correctly.
For ALL apartment stations inthesystem:
1)Call theapartment station from theentrance module and check
thatthecorrectringing toneisproduced. For conventional type
apartment station doorphones, checkthatthebuzzerreedis
correctly positionedto ensurethatsound intensityissufficient. If
necessary,bend thereedto improveacoustic output.
2)Answerthecall from theentrance module bylifting theapartment
station handsetand checkthatvoice signalsaresent and received.
3) Press thedoor lockreleasebutton and checkthattheelectric
lockconnectedto theentrance module from whichtheapartment
station wascalledisactuated.
4)With theapartment station handsetstill off-hook,makeacall to
anotherapartment station from theentrance module.Checkthat
theCall Overtonecanbeheard atthehandsetand thatthevoice
connection isthencut off.
5) Hang uptheapartment station handset.
NOTE:
Ifit is not possible togain access tothe apartment station,
operation MUST be checkedbymeans of a test doorphone
connectedtothe decoder terminalblockfor the apartment
station involved.
For systems with multiple entrance moduleson oneor moreriser
cables, checkthatthesameTYPEdigithasbeenprogrammedon ALL
entrance modulesattheend of installation.
Todo so, proceedasfollows:
•Call anapartment station from anyof theentrance panelsinthe
system.
•CheckthatNONEOFTHEREMAININGentrance panelsgenerates
anerror warning.
•Repeatthisprocedurefor ALL entrance panelsinthesystem, in
eachcasechecking thatno error warnings aregeneratedatALL OF
THEREMAININGentrance panels(i.e., all entrance panelsother
thantheonefrom whichthecall wasmade).
For systems with aguard door switchboard station, DONOTTURN
ON theswitchboard station until all of thecheckslistedabovehave
beencompleted.
ONLYatthispoint, turn on theguard door switchboard station, program
itasdictatedbysystemrequirements, and thenproceedasfollows:
1)CheckthatALL Call Switchboard keyson theapartment station
doorphonesinthesystemoperatecorrectly,making acall to the
switchboard station from eachapartment station.
2)Checkthatthereareno TYPEerrors. If theTYPEcheckhasalready
beencarriedout atall entrance panels, itwill besufficient to:
•
Call anapartment station from theguard door switchboard station
and checkthatthereareno TYPEerrors atanyentrance module.
•Call anapartment station from anyentrance module and check
thatthereareno TYPEerrors attheguard door switchboard
station.
Model826 DIGITALCALL SYSTEM
SYSTEM ACTIVATION -PROGRAMMING
Model826 DIGITALCALL SYSTEM
1- 12 MT124-019