manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Viavi
  6. •
  7. Test Equipment
  8. •
  9. Viavi OneAdvisor 1000 User manual

Viavi OneAdvisor 1000 User manual

VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
SONET Bit Error Rate Testing (BERT)
This quick card describes how to configure and run a SONET Bit Error Rate Test at the full
concatenated line rate. Please note that the OneAdvisor can also test channelized payloads
(DS1, VT1.5, and STS-n). Please refer to the OneAdvisor User’s Guide for information.
LAUNCH TEST
1. Press the Power button to turn on the
OneAdvisor.
2. Press the 100G Module Test icon
at the top of the screen.
3. Tap the Power button and click
to launch the 100G Module.
4. Using the Select Test menu, Quick Launch
menu, or Job Manager, launch the SONET
Bulk BERT test on Port 1 for the desired
Optical Carrier level. For Example:
SONET►OC-3►STS-3c Bulk BERT►P1 Terminate.
5. Tap to open the Tools Panel and
select .
6. Press to continue.
Figure 2: Launch 100G Module
Figure 3: Launch Test
Figure 1: Equipment Requirements
•OneAdvisor 1000 equippedwith the following:
o100G Transport Module
oBERT software release V30.1.0 or greater
oC5LSSONSDH test option for OC-3 and OC-12
oC525GSONSDH test option for OC-48
oC510GSONSDH test option for OC-192
•Optical Transceiver supporting the Optical Carrier
level to be tested (SFP or SFP+)
•LC Attenuators (5dB, 10dB, and/or 15dB)
•Cables to match the optical transceiver and the line under test
•Fiber optic inspection microscope (P5000i or FiberChek Probe)
•Fiber optic cleaning supplies
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
2
Figure 4: Work Order
CONFIGURE TEST
•The followingInformation is needed to
configure the test:
•Optical wavelength
(typically, 1310nm or 1550nm)
•Test Pattern(s) (default is 2^23-1 ANSI)
•BER Pass/Fail Threshold
1. Press the Setup soft key on the top
right side of the screen.
2. Select the Interface/Connector folder.
3. Insert desired SFP into the Port 1 SFP+ slot
on the top of the 100G Transport Module.
4. Review SFP information in the Connector
tab:
►Verify that the SFP operates on the
required wavelength (1310nm or
1550nm).
►Verify that the SFP supports the
required optical carrier level (OC-3,
OC-12, OC-48, or OC-192).
►Note the Min and Max Tx Levels (dBm)
and Max Rx Level (dBm) to assess if
optical attenuators are required.
5. Select the indicated folders and configure
your test as follows. Leave all other values
at default, unless specified in the work order.
6. Press the Results soft key to view the
Test Results screen.
Folder
Option
Value(s)
Interface,
Signal
Clock
Source
Select “Recovered”
unless you are testing
dark fiber with no SONET
equipment
Pattern
Pattern
Mode
ANSI
Pattern
2^23
-1 ANSI
Figure 6: Setup, Interface/Signal
Figure 7: Setup, Pattern
Figure 5: Setup, Interface/Connector/SFP
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
3
RUN TEST
1. Using drop-down menus , select
“Payload/BERT” for the right results display.
2. Select the Laser tab in the Actions panel,
and press . The button will turn yellow
and be relabeled .
3. Press the Restart soft key .
4. Verify the following:
►Level (dBm) is within the Rx Level range
of the SFP.
►Summary LED is green.
►Signal Present LED is green.
►Frame Sync LED is green.
►Path Pointer Present LED is green
►Pattern Sync LED is green.
►Summary/Status results shows ‘ALL
SUMMARY RESULTS OK”
5. Allow the test to run for desired duration and
verify the following:
►Bit/TSE Error Rate result does not
exceed your required threshold.
(0.00E+00 if pass/fail threshold unknown)
CONNECT TO LINE UNDER TEST
•Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (SFP, attenuators, patch
cables, bulkheads)
►Focus fiber on the screen.
►If it appears dirty, clean the fiber end-face
and re-inspect.
►If it appears clean, run inspection test.
►If it fails, clean the fiber and re-run inspection
test. Repeat until it passes.
•If necessary, insert optical attenuators into the
SFP TX and/or RX ports.
•Connect the SFP to the port under test using a
jumper cable compatible with the line under test.
Figure 9: Results, Payload BERT
Figure 8: Inspect Before You Connect
Status Tip
Signal Present LED
not green
Check your cables. Tx and Rx may be
reversed.
Path Pointer Present
LED not green
and AIS-P alarm on
There may be no loop or no connectivity to
the loop. The wrong payload may be
selected (concatenated vs. channelized).
RDI-L alarm on
The Tx Level is too high.
Add an attenuator between the SFP Tx port
and the line under test.
Path Pointer
Adjustments incrementing
Clock Source is set incorrectly.
Change Clock Source to “Recovered.”
Figure 10: Troubleshooting Tips
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
© 2022 VIAVI Solutions, Inc,
Product specifications and descriptions in this
document are subject to change without notice.
Patented as described at viavisolutions.com/patents
Contact Us
To reach the VIAVI office nearest you,
visit viavisolutions.com/contact
+1 844 GO VIAVI
(+1 844 468-4284)
CREATE REPORT
6. In the 100G Module’s Quick Config menu,
change “Pattern” to the next value in the test
plan.
7. Press the Restart soft key to reset results.
8. Allow test to run for desired duration and verify
the following:
►Pattern Sync LED is green.
►Bit/TSE Error Rate or Round Trip Delay
does not exceed your required threshold.
►Repeat steps 6 through 8 for all Patterns
in the test plan. Patterns may include:
•Delay: Measures Round Trip Delay
(RTD) instead of Bit Errors.
RTD values are shown instead of BER
in the “Payload/BERT” results display.
Figure 11: Results, Quick Config
1. Tap to open the Reports Panel and
select . .
2. Tap .
3. A report will be saved to the OneAdvisor 1000
100G Module’s /bert/reports folder.
Figure 12: Create Report

Other Viavi Test Equipment manuals

Viavi MTS 2000 Parts list manual

Viavi

Viavi MTS 2000 Parts list manual

Viavi OneAdvisor 1000 User manual

Viavi

Viavi OneAdvisor 1000 User manual

Viavi T-BERD/MTS 5800 User manual

Viavi

Viavi T-BERD/MTS 5800 User manual

Viavi T-BERD/MTS 5800 User manual

Viavi

Viavi T-BERD/MTS 5800 User manual

Viavi PSD90-3 User manual

Viavi

Viavi PSD90-3 User manual

Viavi SmartOTDR 100 User manual

Viavi

Viavi SmartOTDR 100 User manual

Viavi T-BERD/MTS-4000 v2 Parts list manual

Viavi

Viavi T-BERD/MTS-4000 v2 Parts list manual

Viavi T-BERD/MTS-5800 Parts list manual

Viavi

Viavi T-BERD/MTS-5800 Parts list manual

Viavi T-BERD/MTS 4000 V2 Parts list manual

Viavi

Viavi T-BERD/MTS 4000 V2 Parts list manual

Viavi HST-3000 Parts list manual

Viavi

Viavi HST-3000 Parts list manual

Viavi 4100 Series Parts list manual

Viavi

Viavi 4100 Series Parts list manual

Viavi 3900 Series User manual

Viavi

Viavi 3900 Series User manual

Viavi HST-3000 User manual

Viavi

Viavi HST-3000 User manual

Viavi T-BERD 5800 User manual

Viavi

Viavi T-BERD 5800 User manual

Viavi OneAdvisor 1000 User manual

Viavi

Viavi OneAdvisor 1000 User manual

Viavi OneAdvisor ONA-800 User manual

Viavi

Viavi OneAdvisor ONA-800 User manual

Viavi ONX 580 User manual

Viavi

Viavi ONX 580 User manual

Viavi FIT-82P03-PRO User manual

Viavi

Viavi FIT-82P03-PRO User manual

Viavi ALT-9000 User manual

Viavi

Viavi ALT-9000 User manual

Viavi SmartPocket OLP-39G User manual

Viavi

Viavi SmartPocket OLP-39G User manual

Viavi 8800SX User manual

Viavi

Viavi 8800SX User manual

Viavi T-BERD/MTS-2000 Parts list manual

Viavi

Viavi T-BERD/MTS-2000 Parts list manual

Viavi T-BERD 5800 Parts list manual

Viavi

Viavi T-BERD 5800 Parts list manual

Viavi 7200 Series User manual

Viavi

Viavi 7200 Series User manual

Popular Test Equipment manuals by other brands

I-Tech IT8500plus Series user manual

I-Tech

I-Tech IT8500plus Series user manual

Promax RG3000-E user manual

Promax

Promax RG3000-E user manual

EL-CELL ECC-Opto-10 user manual

EL-CELL

EL-CELL ECC-Opto-10 user manual

Show Tec DMX Tester User instructions

Show Tec

Show Tec DMX Tester User instructions

EL-CELL ECC-OPTO user manual

EL-CELL

EL-CELL ECC-OPTO user manual

Power Master PVLD-3000 Operation manual

Power Master

Power Master PVLD-3000 Operation manual

FRO­NIUS Calibration system 2.0 operating instructions

FRO­NIUS

FRO­NIUS Calibration system 2.0 operating instructions

B+K precision 530 instruction manual

B+K precision

B+K precision 530 instruction manual

Unit UPO1000CS Series quick start guide

Unit

Unit UPO1000CS Series quick start guide

B+K precision CAL73 manual

B+K precision

B+K precision CAL73 manual

Keysight 42030A Operation and service manual

Keysight

Keysight 42030A Operation and service manual

Fluke 5080A manual

Fluke

Fluke 5080A manual

Kal-Equip Cylinder Leakage Tester Kit 2509 operating instructions

Kal-Equip

Kal-Equip Cylinder Leakage Tester Kit 2509 operating instructions

GE ADTS542F user manual

GE

GE ADTS542F user manual

Megger Centrix Evolution Operation and maintenance manual

Megger

Megger Centrix Evolution Operation and maintenance manual

Tesco TS400 Operation manual

Tesco

Tesco TS400 Operation manual

ICS Schneider Messtechnik HT10 user manual

ICS Schneider Messtechnik

ICS Schneider Messtechnik HT10 user manual

Tektronix 507 instruction manual

Tektronix

Tektronix 507 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.