Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undersired
operation.
FCC Caution:Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless siren & strobe alarm is free from physical defects
in material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. Vision does not issue any refunds. This warranty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to :
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent
use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise
modified; (3) units not used in accordance with instruction; (4) damages exceeding the
cost of the product; (5) transit damage, initial installation costs, removal cost, or
reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
-3-
Installation & Operation Manual
ZM 1601 EU
ZM 1601 US
ZM 1601 BR
Wireless Siren & Strobe Alarm
Battery Power
ZM 1601
V0
1001227
6B1Z-16001
Introduction
Thanks for choosing the Vision’s wireless siren & strobe alarm of the home security device.
This siren is a Z-Wave™enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network. Every main
powered Z-Wave™enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate “RF dead-sports”.
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave™ enabled networks. This product will sound a loud siren and flash a strobe light
when an alarm message or alert is received on any Z-Wave™enabled network.
Product Description and Specification
*** For indoor use only ***
Specification: Package Content:
Protocol: Z-Wave™(ZM3102N)
Frequency Range:
868.42MHz (ZM1602EU)
908.42MHz (ZM1602US)
921.42MHz (ZM1602BR)
Operating Range: Up to 100 feet line of sight
Loud Audible Alarm: > 105Db@1meter
LED Strobe Lighting
Operating Temp.: -15°C~ 60°C (5°F~140°F)
Battery: 4pcs x AA Energizer Batteries
Z-Wave™Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_VERSION
Note: COMMAND_CLASS_BASIC Mapping
1pc
1pc
2pcs
4pcs
1pc
ZM 1601 Siren
Adhesive tape
Screw
AAEnergizer Batteries
Installation & Operation
Manual
Installation
Note: If you are installing the entire Z-Wave™ system for the first time, please refer tothe
installation guide of Z-Wave™ Interface Controller before installing ZM 1601.
1. Remove the bracket from the siren by press the locking tab, and then gently slide
up the siren. Observe the correct polarity before insert the batteries.
2. Using the screws or adhesive tape to affix the bracket on the chosen location.
3.
Slide back the cover and screw fastening with the front cover, the LED should go off
.
4. For “Inclusion” in (adding to) a network: Put the Z-Wave™Interface Controller
into “inclusion” mode, and following its instruction to add the ZM 1601 to your
controller. To get in the “inclusion” mode, the distance between siren and controller
is suggested to be in one meter. Open the bracket and press the program switch of
ZM 1601 for 1 second at least & release to be included.After setting, the LED
Setting Lighting should go off, if not, please try again.
For “Exclusion” from (removing from) a network:Set up the Z-Wave™Interface
Controller into “exclusion” mode, and following its instruction to delete the ZM 1601
from your controller. Press the program switch of ZM 1601 for 1 second at least &
release to be excluded.
Note: LED setting light will flash (orange color) continuously in Exclusion condition.
5. Configuration command class:
Parameter 0: Siren/ Strobe Mode, 1 Byte Value: 0=siren and Strobe enable
(default), 1=siren only, 2= Strobe only.
Parameter 1: Alarm auto stop time command, 0=30 seconds (default), 1= 60 secs,
2= 120 secs, 3= siren will not automatically stop.
Operation
1. Normal operation, the LED light will not on.
2. Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will enter
Self-Protection Mode. If the back cover is opened will trigger the Self-Protection
Mode. The alarm time is default 30 seconds.
3. User’s controller should support Z-wave FLiRS technology.
4. Alarm Mode (It’s the status of alarm triggered): It’s based on the user’s
configuration setting of LED flash ON/OFF and Siren ON/OFF.
Note: for Default setting-Siren/Strobe Mode-Parameter will be All enable; Alarm
Auto Stop Time-Parameter will be 30 sec.
5. For safety reason, replace new battery whenever ZM 1601 is triggered.
LED setting light
-2-
-1-
COMMAND_CLASS_SWITCH_BINARY

This manual suits for next models

2

Other Vision Security System manuals

Vision V-LCD1 User manual

Vision

Vision V-LCD1 User manual

Vision XDVR2POSM User manual

Vision

Vision XDVR2POSM User manual

Vision ZM1621MY-5 User manual

Vision

Vision ZM1621MY-5 User manual

Vision ZM 1602 US User manual

Vision

Vision ZM 1602 US User manual

Vision ZM1601 User manual

Vision

Vision ZM1601 User manual

Vision VISEZM1601-5 User manual

Vision

Vision VISEZM1601-5 User manual

Vision V-LED1 User manual

Vision

Vision V-LED1 User manual

Vision 2310b User manual

Vision

Vision 2310b User manual

Vision ZM1601IN-5 User manual

Vision

Vision ZM1601IN-5 User manual

Vision 1330B User manual

Vision

Vision 1330B User manual

Vision ZM 1602 IN-5 User manual

Vision

Vision ZM 1602 IN-5 User manual

Popular Security System manuals by other brands

Encore E 3 installation manual

Encore

Encore E 3 installation manual

Bosch LBB 1946 Installation and operating manual

Bosch

Bosch LBB 1946 Installation and operating manual

Bentel B-TEL99 Installation and Quick guide

Bentel

Bentel B-TEL99 Installation and Quick guide

Defender EL00001 instructions

Defender

Defender EL00001 instructions

Interlogix ATS111xA-N Series Installation sheet

Interlogix

Interlogix ATS111xA-N Series Installation sheet

Pisector GSM-03 user manual

Pisector

Pisector GSM-03 user manual

MobileHelp Classic quick start guide

MobileHelp

MobileHelp Classic quick start guide

Eldes ESIM264 user manual

Eldes

Eldes ESIM264 user manual

ADT SASW3000EN user guide

ADT

ADT SASW3000EN user guide

Avara Basic user manual

Avara

Avara Basic user manual

Aiphone KA-DGR Specifications

Aiphone

Aiphone KA-DGR Specifications

ALC AHS627-23 user guide

ALC

ALC AHS627-23 user guide

FBI XL-1T Installation and setup guide

FBI

FBI XL-1T Installation and setup guide

Scolmore ESP beacon BA4ZM Installation and operation manual

Scolmore

Scolmore ESP beacon BA4ZM Installation and operation manual

Luminite NEXUS NXFOB Setup and user guide

Luminite

Luminite NEXUS NXFOB Setup and user guide

Intelbras AMT 8000 Installation & user guide

Intelbras

Intelbras AMT 8000 Installation & user guide

Sensor Espio Sensor Espio Installation and operation guide

Sensor Espio

Sensor Espio Sensor Espio Installation and operation guide

TeleCare24 Buddi user guide

TeleCare24

TeleCare24 Buddi user guide

manuals.online logo
manuals.online logoBrands