manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vision
  6. •
  7. Security System
  8. •
  9. Vision ZM1601IN-5 User manual

Vision ZM1601IN-5 User manual

Installation & Operation Manual
ZM1601IN-5
ZM1601MY-5
ZM1601EU-5
ZM1601RU-5
ZM1601US-5
ZM1601IL-5
ZM1601KR-5
ZM1601HK-5
ZM1601JP-5
ZM1601BR-5
Wireless Siren & Strobe Alarm
Battery Power
ZM 1601-5
V0
1031128
6B1Z-16005
Introduction
Thanks for choosing the Vision’s wireless siren & strobe alarm of the home security device.
This siren is a Z-Wave™enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™enabled network and it’s security
framework. Every mains powered Z-Wave enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-sport”.
Z-Wave™enabled devices displaying the Z-Wave™logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-Wave™enabled networks. This product will sound a loud siren and flash a strobe light
when an alarm message or alert is received on any Z-Wave™enabled network. When the
device is secure included into Z-Wave network, above communication will be encrypted.
Product Description and Specification
*** For indoor use only ***
Specification:
Package Content:
Protocol: Z-Wave™(ZM5202)
Frequency Range:
865.22MHz (ZM1601IN-5)
868.10MHz (ZM1601MY-5)
868.42MHz (ZM1601EU-5)
869.00MHz (ZM1601RU-5)
908.42MHz (ZM1601US-5)
916.00MHz (ZM1601IL-5)
919~923MHz (ZM1601KR-5)
919.80MHz (ZM1601HK-5)
922~926MHz (ZM1601JP-5)
921.42MHz (ZM1601BR-5)
Operating Range: Up to 100 feet line of sight
Loud Audible Alarm: > 105db@1meter
LED Strobe Lighting
Operating Temp.: -15°C~ 60°C(5°F~140°F)
Battery: 4pcs x AA Energizer Batteries
1pc
1pc
2pcs
4pcs
1pc
ZM 1601 Siren
Adhesive tape
Screw
AAEnergizer Batteries
User Manual
Z-Wave™Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SWITCH_BINARY (mapping COMMAND_CLASS_BASIC)
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO
Installation
Note: If you are installing the entire Z-Wave™ system for the first time, please refer to the
installation guide of Z-Wave™ Interface Controller before installing ZM 1601.
1. Remove the bracket from the siren by press the locking tab, and then gently slide
up the siren. Observe the correct polarity before insert the batteries.
2. Using the screws or adhesive tape to affix the bracket on the chosen location.
3.
Slide back the front cover, and then the LED should go off
.
4. LED Status for Z-Wave Network:
After power on, the LED setting light will flash if the siren has not been included yet.
After power on, the LED setting light will go off if the siren has been included.
5. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into
“inclusion”mode, and following its instruction to add the ZM 1601 to your controller.
To get in the “inclusion”mode, the distance between siren and controller is
suggested to be in one meter. Open the bracket and press the program switch of
ZM 1601 for 1 second at least & release to be included.After setting, the LED
Setting Light should go off, if not, please try again. (After sending one time’s
Z-Wave NIF and not be included then it will send 4 times NWI in every 4 ~ 6
seconds for auto inclusion. The LED setting light will flash again if the siren has not
been included or the LED setting light will go off after inclusion.)
For “Exclusion”from (removing from) a network:Set up the Z-Wave™Interface
Controller into “exclusion”mode, and following its instruction to delete the ZM 1601
from your controller. Press the program switch of ZM 1601 for 1 second at least &
release to be excluded. After setting The LED setting light will flash again
-2-
-1-
Note:
a. LED setting light will flash continuously in Exclusion condition.
b. All user and network settings will be cleared and the device reset to factory
defaults when the device is excluded.
For “Association”: removing the back cover of the ZM1601 to get into “Awake”
mode, then put the Z-Wave Interface Controller into “association”, and following its
instruction to association the ZM1601 with other device. Close the back cover
after “association”done, afterward the ZM1601 will get into “Sleep”mode for power
saving. Support one association group (5 nodes).
6. Configuration command class:
Byte
Value
Parameter 1
(Siren/Strobe Mode)
1
0 (All Enable) - Default
1 (Siren Only)
2 (Strobe Only)
Parameter 2
(Alarm Auto Stop Time)
1
0 (30 seconds) - Default
1 (60 seconds)
2 (120 seconds)
3 (Will Not Automatically Stop)
(Parameter 1) Siren/Strobe Mode: User can change value from 0 to 2 to turn
either Siren sound, Strobe light, or both when triggered.
(Parameter 2) Alarm Auto Stop Time: User can change the duration of siren time
when triggered.
7. Support OTA Firmware update from controller. Please refer to your controller
manual. We recommend to exclude then include the devices from system after
OTA.
8. All the rest commands depend on Z-Wave standard.
Operation
1. Normal operation, the LED light will not on.
2. Alarm Mode:
Active: It will active the Alarm Mode after receiving Basic Set (ON) or Binary
Switch (ON). The LED Strobe Light & SIREN will be active according to the
Configuration’s setting value.
Stop: It will stop the Alarm Mode after receiving Basic Set (OFF) or Binary Switch
(OFF) which depends on Configuration’s setting value.
Auto Stop: After stopping alarm, it will send Binary Switch Report (0x00)
3. Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will
enter the Self-Protection Mode which will active LED Strobe Light & SIREN at the
same time. The Alarm Mode will be triggered If the back cover has been opened
during the Self-Protection Mode If the device is at low battery status, then it will
send Low Voltage Report (COMMAND_CLASS_BATTERY). The Stop method is
same as the Alarm Mode. Open the bracket or close the bracket after 5 seconds will
send notification.
4. Battery Capacity Detection:
* Use “Battery Get”command to have the battery capacity back in % (hexadecimal)
* Auto Battery Capacity Detection
* Low Battery Report at 4.8V (+/- 0.15V)
5. Support Explorer Frame Function
Alarm
Version 1
Notification
Version 4
Alarm Type
0x03
Alarm Level
0x00 (Trigger) /
0xFF (Non Trigger)
Notification Type
0x07
Notification Event
0x03 (Trigger) /
0x00 (Non Trigger)
-3-
-4-
Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interferene by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undersired
operation.
FCC Caution:Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless siren & strobe alarm is free from physical defects
in material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. Vision does not issue any refunds. This warranty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to :
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent
use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise
modified; (3) units not used in accordance with instruction; (4) damages exceeding the
cost of the product; (5) transit damage, initial installation costs, removal cost, or
reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
-5-

This manual suits for next models

9

Other Vision Security System manuals

Vision ZM1621MY-5 User manual

Vision

Vision ZM1621MY-5 User manual

Vision ZM 1602 US User manual

Vision

Vision ZM 1602 US User manual

Vision ZM 1602 IN-5 User manual

Vision

Vision ZM 1602 IN-5 User manual

Vision VISEZM1601-5 User manual

Vision

Vision VISEZM1601-5 User manual

Vision 1330B User manual

Vision

Vision 1330B User manual

Vision ZM 1601 EU User manual

Vision

Vision ZM 1601 EU User manual

Vision XDVR2POSM User manual

Vision

Vision XDVR2POSM User manual

Vision 2310b User manual

Vision

Vision 2310b User manual

Vision ZM1601 User manual

Vision

Vision ZM1601 User manual

Vision V-LCD1 User manual

Vision

Vision V-LCD1 User manual

Vision V-LED1 User manual

Vision

Vision V-LED1 User manual

Popular Security System manuals by other brands

Inner Range CONCEPT IQ user manual

Inner Range

Inner Range CONCEPT IQ user manual

SecurityIng Universal CCTV Security Camera System installation guide

SecurityIng

SecurityIng Universal CCTV Security Camera System installation guide

Security Merchants Avolution user guide

Security Merchants

Security Merchants Avolution user guide

Evolveo Alarmex Pro manual

Evolveo

Evolveo Alarmex Pro manual

Poolguard DAPT-2 installation instructions

Poolguard

Poolguard DAPT-2 installation instructions

Defender SN502-4CH instruction manual

Defender

Defender SN502-4CH instruction manual

Patrol Hawk Vcare user manual

Patrol Hawk

Patrol Hawk Vcare user manual

Axis F34 installation guide

Axis

Axis F34 installation guide

Eagle Alarm Verification Products 2244 installation instructions

Eagle Alarm Verification Products

Eagle Alarm Verification Products 2244 installation instructions

BASETech 1546853 operating instructions

BASETech

BASETech 1546853 operating instructions

Tecnoalarm Evolution EV SAEL BWL quick start guide

Tecnoalarm

Tecnoalarm Evolution EV SAEL BWL quick start guide

Defender 4K1T4B4 manual

Defender

Defender 4K1T4B4 manual

Linear CP-90 Programming manual

Linear

Linear CP-90 Programming manual

FBII XL-2T user guide

FBII

FBII XL-2T user guide

ADEMCO RapidEye plus Installation and setup guide

ADEMCO

ADEMCO RapidEye plus Installation and setup guide

Click SG-09N user manual

Click

Click SG-09N user manual

Lascar EL-WiFi-Alert quick start guide

Lascar

Lascar EL-WiFi-Alert quick start guide

Amico Alert-4 Operation & maintenance manual

Amico

Amico Alert-4 Operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.