Hardware Installation Guide
Managed Gigabit Ethernet Switch
IE-SW-AL08M-8GT (Part No. 2682350000)
1. Introduction
Ethernet Switches from Weidmüller are designed for industrial applications and fitted with
a robust housing. To ensure reliable, error-free operation, and to prevent damage or
injury, please read the operating instructions, all safety information provided in this
document and any other safety information that were supplied with the product.
2. Safety notice
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/E
U
.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
 Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
o Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
 Do not block air ventilation holes.
o Ne bouchez pas les orifices de ventilation.
 If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
o Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
 Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
o Doit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas
dépasser 75 degrés C
.
Intended use
The device is intended for the realization of communication networks within an industrial environment,
it is intended to be used in a restricted access location. The device may only be used within the scope
of the specified technical data. The device is intended to be mounted to a well-grounded mounting
surface, such as a metal panel. Any other use may result in unintentional malfunction and damage.
Observing the documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not
exceed the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
 Ethernet Switch
 Hardware Installation Guide (printed)
 6-Pin Terminal connector
 Serial console cable
 Protective caps for RJ45 ports
4. Panel Layouts
1. Terminal block for power input (PWR1 /
PWR2) and fault relay (output)
2. Power Input LEDs (PWR1 / PWR2)
3. Fault LED (Power fault / Port link loss)
4. Status LED Ring Master
5. Status LED Ring Enabled
6. Reset Button
7. 8 x 10/100/1000BASE-T(X) Ports
8. LAN port Link/Activity LED
9. LED for speed indication (Green = 1000
Mbps, Amber = 100 Mbps, Off = 10 Mbps)
10. Article Number
11. Serial Console Port (115200 Baud, 8 Data
Bit, No Parity, 1 Stop Bit, No Flow Control)
12. Grounding screw / Frame ground (Note:
The shielding ground of the LAN port is
electrically connected to the grounding
screw)
13. DIN-Rail kit
5. Mounting Dimensions (units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Place the mounting clip
from above onto the mounting rail.
STEP 2: Press the device against
the DIN rail until the fastening
element engages on the mounting
rail.
To remove the Ethernet Switch from the DIN-rail pull down the latch with a screwdriver
then move the device away from the DIN rail and lift it up.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding surface
prior to connecting devices.
- This product is intended to be mounted to a well-grounded mounting
surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected to the
ground connection (screw).
8. Wiring Redundant Power Inputs and Fault Alarm
Relay
The switch supports redundant power supply inputs and provides a fault alarm relay for
detecting the user-configurable failure events
 Interruption of Power 1 or Power 2 and
 Link Loss of Ethernet Ports.
Refer to illustration below for correct wiring.
4 5 6 V1.2 / 2021-05-17
Warning / Avertissement
 Take into consideration the following guidelines before wiring the device
o Tenez compte des directrices suivantes avant de câbler l’appareil.
 Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
o Le bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
 The temperature rating of the input connection cable should higher than
105°C.
o La température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
 Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
o Fourni par la source SELV évaluée uniquement par l'alimentation UL
61010
-
1 or 61010
-
2
-
201.
Behavior of fault alarm relay (can be triggered by configurable events power
failure or port link down):
 Relay contact is closed if the device is powered-off.
 Relay contact is open if the device is powered-on and no alarm conditions exist (neither
Power Failure Alarms nor Port Link Loss Alarms are activated (Web menu Warnings 
Fault Relay Alarm).
 Relay contact closes if any of an activated alarm condition happens.
9. Communication Connections
Switch IE-SW-AL08M-8GT is equipped with:
8 x 10/100/1000BASE-T(X) Ethernet ports (Auto MDI-X)
Please only use cables suitable for the respective type of communication and ensure
that signals are protected from possible interference.
9.1 10/100/1000BASE-T(X) RJ45 Ports
The 10/100/1000BASE-T(X) ports located on Ethernet Switch’s front panel are used to
connect to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type)
ports and MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-
schemes are supported (Automatic crossover function).
10/100/1000BASE-T(X) RJ45 Pinouts
8-Pin RJ45
Port
10/100BASE-T(X) MDI/MDI-X 1000BASE-T MDI/MDI-X
Pin No. MDI port MDI-X port Pin No. MDI port MDI-X port
1
TD+(transmit)
RD+(receive)
1
BI_DA+
BI_DB+
2 TD-(transmit) RD-(receive) 2 BI_DA- BI_DB-
3
RD+(receive)
TD+(transmit)
3
BI_DB+
BI_DA+
4
Not used
Not used
4
BI_DC+
BI_DD+
5
Not used
Not used
5
BI_DC
-
BI_DD
-
6
RD
-
(receive)
TD
-
(transmit)
6
BI_DB
-
BI_DA
-
7
Not used
Not used
7
BI_DD+
BI_DC+
8
Not used
Not used
8
BI_DD
-
BI_DC
-
9.2 RS232 Console Port
The RS232 Interface with RJ45 connector can be used to access the switch console for
configuration. Additional it can be applied with external Backup/Restore module IE-
EBR-MODULE-RS232-ALM (Article no. 2682610000).
Pinouts Serial
Console Port:
10. User Management
10.1 Device Access (Login to Web Interface)
The Web interface of the Switch can be accessed via following factory default settings:
IP address / Netmask: 192.168.1.110 / 255.255.255.0
User name: admin
Password: Detmold
Connect the PC to any Ethernet port of the managed Switch and set the PC’s IP
address to a free one of range 192.168.1.0 / 255.255.255.0
Start a web browser and enter the IP address of the connected Switch into the
browser’s address line (http://192.168.1.110). After the appearance of prompt (login)
enter the login credentials. After confirmation of your input with "OK" the home page of
the switch will be displayed.
Note: For more detailed information about configuration and use of the device features
please read the downloadable manual from Weidmüller’s website (Product catalogue 
Automation & Software  Industrial Ethernet  Advanced Line managed Switches 
Select Product  Click and expand section „Downloads“  Download needed software
or documentation).
10.2 Reset Button
 Press reset button for 2 to 3 seconds to reboot the switch (Warm Start).
 Press reset button for >= 5 seconds to reset the switch to factory default settings.
11. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED
Color
Status
Description
PWR1
Green
On
Power is supplied to power input PWR1.
PWR2
Green
On
Power is supplied to power input PWR2.
R-MSTR
(
Ring Master
)
Green On Is Ring Master of an enabled O-Ring.
Ring Green
On
O
-
Ring
redundancy
is enabled
.
Blinking
Ring structure is broken (No redundancy)
.
LNK/ACT Green
On
Port’s link is active.
Off
Port’s link is inactive.
Blinking
Data is transmitted.
10/100/1000M Green /
Amber
Green
Port speed is
set to
1000 Mbps.
Amber
Port speed is
set to
100 Mbps.
Off
Port speed is
set to
10 Mbps.
FAULT Amber On Fault Relay indication for Power failure and
Port link loss.
12. Specifications
Technology
Ethernet Standards
IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-TX
IEEE 802.3z for 1000BASE-X
IEEE 802.3x for flow control
IEEE 802.3az Energy-Efficient Ethernet
IEEE 802.3ad for port trunk with LACP
IEEE 802.1D for STP (Spanning Tree protocol)
IEEE 802.1w for RSTP (Rapid Spanning Tree protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1X for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Pr
otocol)
Processing Type
Store and Forward
MAC Table
size
8
K
Packet
buffer
size
4 Mbit
Backplane
bandwidth
16
Gbps
Jumbo
frame
support
Up to 9.6 kBytes
Interfaces
RJ45 Ports 10/100/1000BASE-T(X) auto negotiation speed, F/H duplex
mode and auto
MDI/MDI
-
X connection
RS232 Console Port RS232 Interface with RJ45 connector for Console access and
useable with external Backup/Restore module
LED Indicators PWR1, PWR2 (Power), Fault (Relay), Ring Master, Ring
Status, Port Link/Activity, Port
Full/Half Duplex Mode
Relay Contact
Max. 1A @ 24 V DC for Power Failure and Port Link Loss
Power
Input Voltage
24
V
DC
(12
-
48
V
DC),
2
redundant
inputs
Power
Consumption
(typ.)
13.2 Watts
Connection
One removable 6
-
pin terminal block, Wiring
cable 12
-
24AWG
Overload Current Protect.
Present
Reverse Polarity Protect.
Present
Physical Characteristics
Housing
IP30 protection, metal
Dimension (W x H x D)
54.3 x 145.1 x 108.3 mm (2.13 x 5.71 x 4.26 inch.)
Weight
779 g
Installation
DIN
-
rail
Environmental conditions
Operating Temperature
-
40
to
75°C
(
-
40
to
167°F)
Storage Temperature
-
40 to 85°C (
-
40 to 185°F)
Ambient Relative Humidity
5 to 95% (non
-
condensing)
Operating Altitude
Up to 2000 m
Regulatory
Approvals
Safety
UL 61010
-
1;
UL 61010
-
2
-
201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock
IEC 60068
-
2
-
27
Free Fall
IEC 60068
-
2
-
31
Vibration
IEC 60068
-
2
-
6
MTBF
Time
508
.
672
hrs
Database
Telcordia SR332
Warranty
Time Period
5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

Other manuals for IE-SW-AL08M-8GT

2

This manual suits for next models

1

Other Weidmüller Switch manuals

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller IE-SW-SL28M User manual

Weidmüller

Weidmüller IE-SW-SL28M User manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Popular Switch manuals by other brands

Manhattan 160599 user manual

Manhattan

Manhattan 160599 user manual

Diamond Epsilon-12G2 user manual

Diamond

Diamond Epsilon-12G2 user manual

Rack World CAT5 Quick setting guide

Rack World

Rack World CAT5 Quick setting guide

ADDER SmartView MultiScreen manual 

ADDER

ADDER SmartView MultiScreen manual 

CTS IPS-3120-PoE++ Quick installation guide

CTS

CTS IPS-3120-PoE++ Quick installation guide

Kramer VP-794 user manual

Kramer

Kramer VP-794 user manual

Optex i-oneX T manual

Optex

Optex i-oneX T manual

TP-Link TL-SF1008P user guide

TP-Link

TP-Link TL-SF1008P user guide

ZUUM MAHCL4X4V2 manual

ZUUM

ZUUM MAHCL4X4V2 manual

HP ProCurve 5400zl Series Installation and getting started guide

HP

HP ProCurve 5400zl Series Installation and getting started guide

Goobay 60812 manual

Goobay

Goobay 60812 manual

SMC Networks TigerStack III SMC6824MPE Specification sheet

SMC Networks

SMC Networks TigerStack III SMC6824MPE Specification sheet

ATEN MASTER VIEW CS-142 user manual

ATEN

ATEN MASTER VIEW CS-142 user manual

Digitus DN-652120 Quick installation guide

Digitus

Digitus DN-652120 Quick installation guide

Ines RFSAI-61B manual

Ines

Ines RFSAI-61B manual

Allen-Bradley 105-C09 Series Installation instruction

Allen-Bradley

Allen-Bradley 105-C09 Series Installation instruction

Alcatel-Lucent 7450 System management guide

Alcatel-Lucent

Alcatel-Lucent 7450 System management guide

Allied Telesis AT-8100L/8POE-E Specifications

Allied Telesis

Allied Telesis AT-8100L/8POE-E Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.