Weidmüller IE-SW-EL08-8GTPoE Manual

1 2 3
Hardware Installation Guide
Unmanaged Gigabit Ethernet PoE Switches
IE-SW-EL08-8GTPoE (Part No. 2682400000)
1. Introduction
Ethernet Switches from Weidmüller are designed with a very compact housing size and
are fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided in
this document and any other safety information that were supplied with the product.
2. Safety notice
Switch off the electrical power before removing the power connection!
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas dépasser 75 degrés C.
Intended use
The device is intended for the realization of communication networks within an industrial environment, it is
intended to be used in a restricted access location. The device may only be used within the scope of the
specified technical data. The device is intended to be mounted to a well-grounded mounting surface, such as
a metal panel. Any other use may result in unintentional malfunction and damage. Observing the
documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not exceed
the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Protective caps for RJ45 ports
4. Panel Layouts
1. Terminal block for power input PWR1/PWR2 and
Power failure relay (output)
2. Grounding screw / Frame ground (Note: The
shielding ground of the LAN port is electrically
connected to the grounding screw)
3. Power input LEDs (PWR1 / PWR2)
4. Fault LED (PWR1 / PWR2 fault)
5. 10/100/1000Base-T(X) PoE+ ports (P.S.E)
6. Article Number
7. LED RJ45 port Link/Activity
8. LED for PoE power injection
9. DIP switch for enabling / disabling Power Fault
relay
SW1 ON: Switch relay if power 1 fails
SW2 ON: Switch relay if power 2 fails
10. DIN-Rail kit
5. Mounting Dimensions
(units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Insert the top of the
DIN-Rail into the slot just below
the stiff metal spring.
STEP 2: The DIN-Rail
attachment unit will snap into
place as shown below.
To remove the DIN-rail from the Ethernet Switch, simply reverse Steps 1 and 2.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding
surface prior to connecting devices.
- This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected
to the ground connection (screw).
4 5 6 V1.0 / 2020-10-29
8. Wiring Redundant Power Inputs and Power Fault
Relay
The switch supports redundant power supplies and provides a power fault relay which
can be used for alarming in case of interruption of Power 1 or Power 2. For wiring via 6-
pin terminal connector please refer to below illustration.
Warning / Avertissement
Take into consideration the following guidelines before wiring the
device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG.
Torque value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher
than 105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Use Copper Conductors Only.
oUtilisez uniquement des conducteurs en cuivre.
Supplied by SELV or double insulation source evaluated by UL
61010-1 or 61010-2-201 power supply only.
oFourni par la source SELV ou double isolation évaluée uniquement
par l'alimentation UL 61010-1 or 61010-2-201.
Note about behavior of power failure relay:
Relay contact is closed if the device is powered-off.
Relay contact always is open if the device is powered either by PWR1 or PWR2 and
if DIP switches 1 and 2 for power control are set to off.
Relay contact closes if DIP switch 1 is set to ON and PWR1 fails.
Relay contact closes if DIP switch 2 is set to ON and PWR2 fails.
9. Communication Connections
Switch IE-SW-EL08-8GTPoE is equipped with the following communication interfaces:
8 x 10/100/1000Base-T PoE ports (P.S.E.)
9.1 10/100/1000Base-T(X) PoE ports (P.S.E)
For communication without PoE sourcing the switch supports auto negotiation speed,
Full/Half duplex mode and auto MDI/MDI-X connection, means automatic setting of
pinouts for both MDI ports (NIC-type) or MDI-X ports (HUB/Switch-type).
In case of active PoE sourcing the switch uses the pinout of “Alternative A, MDI mode” of
802.3af/802.3at standards. Please see the details in the following table.
Pinouts 10/100/1000Base-T(X) PoE ports (P.S.E)
8-Pin RJ45
Port
10/100 Base-T(X) MDI/MDI-X 1000Base-T MDI/MDI-X
Pin
No. MDI port MDI-X port Pin
No. MDI port MDI-X port
1 TD+(transmit) with
PoE Power + RD+(receive) 1 BI_DA+ with
PoE Power + BI_DB+
2 TD-(transmit) with
PoE Power + RD-(receive) 2 BI_DA- with
PoE Power + BI_DB-
3 RD+(receive) with
PoE Power - TD+(transmit) 3 BI_DB+ with
PoE Power - BI_DA+
4 Not used Not used 4 BI_DC+ BI_DD+
5 Not used Not used 5 BI_DC- BI_DD-
6 RD-(receive) with
PoE Power - TD-(transmit) 6 BI_DB- with
PoE Power - BI_DA-
7 Not used Not used 7 BI_DD+ BI_DC+
8 Not used Not used 8 BI_DD- BI_DC-
Note:
According to IEEE 802.3af/at standards, the PD shall be implemented to be insensitive to
the polarity of the power supply and shall be able to operate per MDI mode and MDI-X
mode. However, some PDs only support MDI mode or MDI-X mode only.
If the PD only supports PoE MDI mode (V+, V+, V-, V- for pins 1, 2, 3, 6), choose a
cross-over Ethernet cable to connect the PD and the switch. If the PD only supports PoE
MDI-X mode (V-, V-, V+, V+ for pins 1, 2, 3, 6), choose a straight-through Ethernet cable
between the PD and the Switch.
Total PoE Budget
For the total PoE power budget, the switch will provide 60 Watts from 12 to 23 VDC input
voltage and 120 Watts from 24 to 57 VDC input voltage. The total power budget is the
total amount of reserved PoE power based on the PoE class of the PoE device. If a
newly connected PoE device causes the total reserved power to exceed the total power
budget, the newly connected PoE device will be denied power.
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green
On Power is being supplied to power input
PWR1.
Off Power is not being supplied to power input
PWR1.
PWR2 Green
On Power is being supplied to power input
PWR2.
Off Power is not being supplied to power input
PWR2.
FAULT Amber
On Indicates PWR1 or PWR2 fault (if
corresponding DIP switches are set to ON).
Off If DIP switches are set to OFF or no power
failure.
LNK/ACT
Green
/
Amber
Green Port’s link is active at 1000 Mbps.
Amber Port’s link is active at 10/100 Mbps.
Off Port’s link is inactive.
PoE active Green On PoE power injection is active.
Off PoE power injection is inactive.
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3af/at for Power over Ethernet
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size 4K
Packet buffer size 192 KB
Backplane bandwidth 16 Gbps
Jumbo frame support up to 9.72 KB
Interfaces
RJ45 Ports 10/100/1000Base-T(X) PoE ports (P.S.E.) compliant to PoE
standard IEEE 802.3af/at.
LED Indicators PWR1, PWR2 (Power), Power Fault, Port Link/Activity,
PoE
Relay Contact Max. 1A @ 24 VDC (normally open)
DIP Switches Enabling/Disabling relay alarm for PWR1/PWR2 failure
Power
Input Voltage 12/24/48 V DC (12 - 57 V DC), 2 redundant inputs
Input Current 6.60 A @ 12 V DC; 5.86 A @ 24 V DC; 2.32 A @ 57 V DC
Connection One removable 6-pin terminal block, Wiring cable 12-24AWG
Overload Current
Protection Present
Reverse Polarity
Protection Present
PoE
Total power budget 60 W @ 12 – 23 V DC
120 W @ 24 -57 V DC
PoE Pinout Mode A: Pin 1, 2 (V+); Pin 3, 6 (V-); Alternative A; MDI
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 41 x 144.3 x 94.9 mm (1.62 x 5.68 x 3.74 in)
Weight 675 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Operating Altitude Up to 2000 m
Regulatory Approvals
Safety UL 61010-1; UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time 532.527 hrs
Database Telcordia SR-332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

1

Other Weidmüller Switch manuals

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Popular Switch manuals by other brands

Exsys EX-1240HMVS manual

Exsys

Exsys EX-1240HMVS manual

Zte ZXR10 8900 Series Command reference

Zte

Zte ZXR10 8900 Series Command reference

CYP PU-2H8HBTE-AD Operation manual

CYP

CYP PU-2H8HBTE-AD Operation manual

rotork SS Safety manual

rotork

rotork SS Safety manual

Broadcast Devices CDS-302 Technical reference manual

Broadcast Devices

Broadcast Devices CDS-302 Technical reference manual

Moxa Technologies TN-G4516-8GPoE-4XGPoE-WV-T quick start guide

Moxa Technologies

Moxa Technologies TN-G4516-8GPoE-4XGPoE-WV-T quick start guide

Volt VAC-ZWM8-BBZ installation instructions

Volt

Volt VAC-ZWM8-BBZ installation instructions

Mellanox Technologies Grid Director 4700 installation manual

Mellanox Technologies

Mellanox Technologies Grid Director 4700 installation manual

Zte ZXR10 5900 Series user manual

Zte

Zte ZXR10 5900 Series user manual

FlowLine LP50 Series owner's manual

FlowLine

FlowLine LP50 Series owner's manual

RCA DH3HSL user guide

RCA

RCA DH3HSL user guide

KTI Networks KS-105F-B Series installation guide

KTI Networks

KTI Networks KS-105F-B Series installation guide

Siemens SIMATIC NET SCALANCE XC-100 operating instructions

Siemens

Siemens SIMATIC NET SCALANCE XC-100 operating instructions

Bay Networks 5399 quick start

Bay Networks

Bay Networks 5399 quick start

Articona 386428 Quick installation guide

Articona

Articona 386428 Quick installation guide

Grizzly H8241 instructions

Grizzly

Grizzly H8241 instructions

Lex PowerGATE ReadySwitch Installation instructions & user manual

Lex

Lex PowerGATE ReadySwitch Installation instructions & user manual

Goobay 93893 quick start guide

Goobay

Goobay 93893 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.