Hardware Installation Guide
Unmanaged Gigabit Ethernet Switches
IE-SW-EL08-8GT (Part No. 2682230000)
IE-SW-EL05-4GT-1GESFP (Part No. 2682220000)
1. Introduction
Ethernet Switches from Weidmüller are designed with a very compact housing size and
are fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided
in this document and any other safety information that were supplied with the product.
2. Safety notice
Switch off the electrical power before removing the power connection!
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas dépasser 75 degrés C.
Intended use
The device is intended for the realization of communication networks within an industrial
environment, it is intended to be used in a restricted access location. The device may only be used
within the scope of the specified technical data. The device is intended to be mounted to a well-
grounded mounting surface, such as a metal panel. Any other use may result in unintentional
malfunction and damage. Observing the documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not
exceed the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Protective caps for RJ45 ports and SFP ports
4. Panel Layouts
1. Terminal block for power
input PWR1/PWR2 and
Power failure relay (output)
2. Grounding screw / Frame
ground (Note: The shielding
ground of the LAN port is
electrically connected to the
grounding screw)
3. Power input LEDs (PWR1 /
PWR2)
4. Fault LED (PWR1 / PWR2
fault)
5. SFP port Link/Activity LED
6. SFP slot 1000Base-X
7. 10/100/1000Base-T(X) ports
8. LAN port Link/Activity and
Speed LED (Amber = 10/100
Mbps, Green =1000 Mbps)
9. LAN port Duplex Mode LED
(Amber = full duplex, Off =
half duplex, Blinking =
collisions)
10. LAN port speed LED
(10/100/1000 Mbps)
11. Article Number
12. DIP switch for Enable /
Disable Power Fault relay
SW1 ON: Switch relay for
power 1 error signaling
SW2 ON: Switch relay for
power 2 error signaling
13. DIN-Rail kit
5. Mounting Dimensions (units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Insert the top of the DIN-
Rail into the slot just below the stiff
metal spring.
STEP 2: The DIN-Rail attachment
unit will snap into place as shown
below.
To remove the DIN-rail from the Ethernet Switch, simply reverse Steps 1 and 2.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding surface
prior to connecting devices.
- This product is intended to be mounted to a well-grounded mounting
surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected to the
ground connection (screw).
4 5 6 Edition 6 / 2020-07
8. Wiring Redundant Power Inputs and Power Fault
Relay
The switch supports redundant power supply inputs and provides a power fault relay
which can be used for alarming in case of interruption of Power 1 or Power 2 on the 6-
pin terminal block. Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
Note about behavior of power failure relay:
Relay contact is closed if the device is powered-off.
Relay contact always is open if the device is powered either by PWR1 or PWR2 and if
DIP switches 1 and 2 for power control are set to off.
Relay contact closes if DIP switch 1 is set to ON and PWR1 fails.
Relay contact closes if DIP switch 2 is set to ON and PWR2 fails.
9. Communication Connections
Switch IE-SW-EL08-8GT is equipped with:
8x 10/100/1000Base-T(X) Ethernet ports (Auto MDI-X)
Switch IE-SW-EL05-4GT-1GESFP is equipped with:
4x 10/100/1000Base-T(X) Ethernet ports (Auto MDI-X)
1x 1000Base-X slot to be used with SFP Transceivers (mini-GBIC) [accessories]
Please only use cables suitable for the respective type of communication and ensure
that signals are protected from possible interference.
9.1 10/100/1000Base T(X) RJ45 Ports
The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to
connect to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type)
ports and MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-
schemes are supported (Automatic crossover function).
Pinouts 10/100/1000Base T(X) RJ45
8-Pin RJ45
Port
10/100 Base-T(X) MDI/MDI-X 1000Base-T MDI/MDI-X
Pin No. MDI port MDI-X port Pin No. MDI port MDI-X port
1 TD+(transmit) RD+(receive) 1 BI_DA+ BI_DB+
2 TD-(transmit) RD-(receive) 2 BI_DA- BI_DB-
3 RD+(receive) TD+(transmit) 3 BI_DB+ BI_DA+
4 Not used Not used 4 BI_DC+ BI_DD+
5 Not used Not used 5 BI_DC- BI_DD-
6 RD-(receive) TD-(transmit) 6 BI_DB- BI_DA-
7 Not used Not used 7 BI_DD+ BI_DC+
8 Not used Not used 8 BI_DD- BI_DC-
9.2 1000BaseSFP Port (only IE-SW-EL05-4GT-1GESFP)
The switch is equipped with an 1000BaseSFP slot that can be used with an optional
SFP transceivers (mini GBIC). Please only use SFP modules and cables that are
compatible with each other to establish an optical connection. Weidmüller provides
transceiver models for various distance requirements.
LC-Port with separate Transmit and Receive Port:
Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device
II, and the Rx (receive) port of device I to the Tx (transmit) port of device I
LC-Port Pinouts LC-Port to LC-Port Cable Wiring
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green On Power is being supplied to power input PWR1.
Off
Power is not being supplied to power input PWR1.
PWR2 Green On Power is being supplied to power input PWR2.
Off
Power is not being supplied to power input PWR2.
FAULT Amber On Indicates PWR1 or PWR2 fault (if
corresponding DIP switches are set to ON).
Off
If DIP switches are set to OFF or no power failure.
LNK/ACT (IE-
SW-EL08-8GT)
Green
/
Amber
Green Port’s link is active at 1 Gbps.
Amber Port’s link is active at 10/100 Mbps.
Off Port’s link is inactive.
LNK/ACT (IE-
SW-EL05-4GT-
1GESFP)
Green
On Port’s link is active.
Off Port’s link is inactive.
Full/Half Duplex
(IE-SW-EL08-
8GT)
Amber
On Port is set to Full Duplex Mode.
Off Port is set to Half Duplex Mode.
Blinking Packet collisions detected.
10/100/1000M
(IE-SW-EL05-
4GT-1GESFP)
Amber
On Port speed is 100 Mbps.
Off Port speed is 10 Mbps or 1 Gbps (Full Duplex).
LNK/ACT
1000Base-X
(IE-SW-EL05-
4GT-1GESFP)
Green
On Fiber-Link is active.
Off Fiber-Link is inactive.
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100Base-TX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size IE-SW -EL05-4GT-1GESFP: 1K; IE-SW-EL08-8GT: 4K
Packet buffer size IE-SW-EL05-4GT-1GESFP: 1 Mbit
IE-SW-EL08-8GT: 1.5 Mbit
Backplane bandwidth IE-SW-EL05-4GT-1GESFP: 10 Gbps
IE-SW-EL08-8GT: 16 Gbps
Jumbo frame support IE-SW-EL05-4GT-1GESFP: up to 10 KB
IE-SW-EL08-8GT: 9216 Bytes
Interfaces
RJ45 Ports 10/100/1000BaseT(X) auto negotiation speed, F/H duplex
mode and auto MDI/MDI-X connection
SFP slot 1000Base-X
LED Indicators PWR1, PWR2 (Power), Power Fault, Port Link/Activity,
Port Full/Half Duplex Mode
Relay Contact Max. 1A @ 24 VDC
DIP Switches Enabling/Disabling relay alarm for PWR1/PWR2 failure
Power
Input Voltage 24 V DC (12 - 48 V DC), 2 redundant inputs
Input Current @24 VDC IE-SW-EL05-4GT-1GESFP: 0.18 A; IE-SW-EL08-8GT: 0.2 A
Connection One removable 6-pin terminal block, Wiring cable 12-24AWG
Overload Current
Protection Present
Reverse Polarity
Protection Present
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 26.1 x 144.3 x 94.9 mm (1.03 x 5.68 x 3.74 in)
Weight IE-SW-EL05-4GT-1GESFP: 403 g; IE-SW-EL08-8GT: 390 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity 5 to 95% (non-condensing)
Altitude up to 2000 m
Regulatory Approvals
Safety UL 61010-1, UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time IE-SW-EL08-8GT: 926.332 hrs
IE-SW-EL05-4GT-1GESFP: 1.861.840 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

3

Other Weidmüller Switch manuals

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller IE-SW-SL28M User manual

Weidmüller

Weidmüller IE-SW-SL28M User manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Popular Switch manuals by other brands

D-Link DUB-104 Quick installation guide

D-Link

D-Link DUB-104 Quick installation guide

Encore ENHGS-224 Specifications

Encore

Encore ENHGS-224 Specifications

Ivep QAK Setting manual

Ivep

Ivep QAK Setting manual

StarTech.com 5G4AINDRM-USB-A-HUB quick start guide

StarTech.com

StarTech.com 5G4AINDRM-USB-A-HUB quick start guide

ATEN CM1942 user manual

ATEN

ATEN CM1942 user manual

Asante FriendlyNET 4024P user guide

Asante

Asante FriendlyNET 4024P user guide

Stübbe NIS Mounting and instruction manual

Stübbe

Stübbe NIS Mounting and instruction manual

LDT Digital-Professional Series Assembly instruction

LDT

LDT Digital-Professional Series Assembly instruction

DOLD SAFEMASTER STS Mounting and operating instruction

DOLD

DOLD SAFEMASTER STS Mounting and operating instruction

ZyXEL Communications GS2210 Series user guide

ZyXEL Communications

ZyXEL Communications GS2210 Series user guide

H3C S6805 Series Hardware Information

H3C

H3C S6805 Series Hardware Information

Dataprobe iBoot-G2 instructions

Dataprobe

Dataprobe iBoot-G2 instructions

TRENDnet TE100-S24g Specifications

TRENDnet

TRENDnet TE100-S24g Specifications

Intellinet 505710 Series user manual

Intellinet

Intellinet 505710 Series user manual

StarTech.com ST4100USBBL Specifications

StarTech.com

StarTech.com ST4100USBBL Specifications

Elvaco CMeX10 manual

Elvaco

Elvaco CMeX10 manual

Roland V-60HD Reference manual

Roland

Roland V-60HD Reference manual

DeLOCK 11482 user manual

DeLOCK

DeLOCK 11482 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.