manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Weidmüller
  6. •
  7. Switch
  8. •
  9. Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

1 2 3
Hardware Installation Guide
Unmanaged Fast Ethernet Switches
IE-SW-EL08-6TX-2SC (Part No. 2682170000)
IE-SW-EL08-6TX-2SCS (Part No. 2682180000)
1. Introduction
Ethernet Switches from Weidmüller are designed with a very compact housing size and
are fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided in
this document and any other safety information that were supplied with the product.
2. Safety notice
Switch off the electrical power before removing the power connection!
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas dépasser 75 degrés C.
Intended use
The device is intended for the realization of communication networks within an industrial environment,
it is intended to be used in a restricted access location. The device may only be used within the scope
of the specified technical data. The device is intended to be mounted to a well-grounded mounting
surface, such as a metal panel. Any other use may result in unintentional malfunction and damage.
Observing the documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not
exceed the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
3-Pin Terminal connector
Protective caps for RJ45 ports and Fiber optic ports
4. Panel Layouts
1. Terminal block for power input
PWR
2. Grounding screw / Frame
ground
Note: The shielding ground of
the LAN port is electrically
connected to the grounding
screw.
3. Power input LED‘s (PWR)
4. 100BaseFX Port Link/Activity
LED‘s
5. 100BaseFX Port (Multi-Mode)
6. 100BaseFX Port (Single-
Mode)
7. 10/100BaseT(X) ports
8. LAN port Link/Activity LED
9. LAN port 10/100 Mbps LED
10. Article Number
11. DIN-Rail kit
12. Screw holes for wall
mounting kit
5. Mounting Dimensions
IE-SW-EL08-6TX-2SC(S) (units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Insert the top of the DIN-Rail
into the slot just below the stiff metal
spring.
STEP 2: The DIN-Rail attachment
unit will snap into place as shown
below.
To remove the DIN-rail from the Ethernet Switch, simply reverse Steps 1 and 2.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding
surface prior to connecting devices.
- This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected
to the ground connection (screw).
4 5 6 V1.0 / 2020-10-29
8. Wiring the Power Input
The switch supports a single power supply input which is located on the 3-pin terminal
block. Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
9. Communication Connections
Switch IE-SW-EL08-6TX-2SC is equipped with following communication interfaces:
6x 10/100Base-T(X) ports
2x 100BaseFX port with SC Connector (Multi-mode)
Switch IE-SW-EL08-6TX-2SCS is equipped with following communication interfaces:
6x 10/100Base-T(X) ports
2x 100BaseFX port with SC Connector (Single-mode)
Please only use cables suitable for the respective type of communication and ensure that
signals are protected from possible interference.
9.1 10/100Base T(X) RJ45 Ports
The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to connect to
Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) ports and MDI-
X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-schemes are supported.
(Automatic crossover function)
Each RJ45 Ethernet port independently supports auto-negotiation for recognizing the
transmission speed 10 Mbps or 100 Mbps according to the IEEE802.3 standard. This
means that some of connected Ethernet devices could operate at 10 Mbps, while at the
same time other nodes are operating at 100 Mbps.
10/100Base T(X) RJ45 Pinouts
MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45
Pin Signal Pin Signal
1 Tx+ 1 Rx+
2 Tx- 2 Rx-
3 Rx+ 3 Tx+
6 Rx- 6 Tx-
Note about possible loss of data packages in case of “Duplex mismatching”
If the switch’s auto-negotiation port is connected to a non-
negotiating device,
then the switch will set its port transmission speed same as the connected device
but is unable to correctly detect the duplex mode.
As result the port is set to the correct speed but is using
always the half duplex
mode as required by the IEEE 802.3u standard in such cases.
For correct transmission, the non-negotiating port must be set to half-
duplex
mode (speed can be either 10 Mbps or 100 Mbps, it always will be recognized
automatically by an Auto-Negotiation-Device).
9.2 100Base-FX Fiber Ports
The switch is equipped with 2 * 100BaseFX Fiber ports with SC connectors. For connecting
fiber ports between 2 devices consider to connect wire Tx (transmit) of device 1 to wire Rx
(receive) of device 2, and vice versa. Remember that fiber optic connections generally are
using the full-duplex transmission mode.
SC-Port Pinouts SC-Port to SC-Port Cable Wiring
ATTENTION
This is a Class 1 Laser/LED product. To avoid causing serious damage to
your eyes, do not stare directly into the Laser Beam.
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR Green On Power is being supplied to power input
Off Power is not being supplied to power input
LNK/ACT Green
On Port’s link is active.
Off Port’s link is inactive.
Blinking Transmitting data.
10/100M Amber On Port speed 100 Mbps
Off Port speed 10 Mbps
100M (Fiber
Ports) Green
On Port’s link is active.
Off Port’s link is inactive.
Blinking Transmitting data.
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size 1K
Packet buffer size 448 Kbit
Backplane bandwidth 1.6 Gbps
Interface
RJ45 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex mode and
auto MDI/MDI-X connection
LED Indicators PWR1, PWR2 (Power), Port Link/Activity, Port Speed
Fiber Ports IE-SW-EL08-6TX-2SC IE-SW-EL08-6TX-2SCS
Fiber Ports number 2 2
Fiber Ports standard 100Base-FX 100Base-FX
Fiber Mode Multi-mode Single-mode
Fiber Diameter (μm) 62.5/125 μm
50/125 μm 9/125 μm
Connector Type SC SC
Typical Distance (km) 2 km 30 km
Wavelength (nm) 1310 nm 1310 nm
Max. Output Optical
Power (dbm) -14 dbm -8 dbm
Min. Output Optical
Power (dbm) -23.5 dbm -15 dbm
Max. Input Optical
Power (Saturation) 0 dbm 0 dbm
Min. Input Optical
Power (Sensitivity) -31 dbm -34 dbm
Link Budget (db) 7.5 db 19 db
Power IE-SW-EL08-6TX-2SC IE-SW-EL08-6TX-2SCS
Input Voltage 24 V DC (10 - 30 V DC), 1 single input
Input Current@24 VDC 0.14 A 0.14 A
Connection One removable 3-pin terminal block, Wiring cable 12-24AWG
Overload Current Protec.
Present
Reverse Polarity Protec.
Present
Physical Characteristics IE-SW-EL08-6TX-2SC IE-SW-EL08-6TX-2SCS
Housing IP30 protection, metal
Dimension (W x H x D) 41 x 115 x 84 mm (1.61 x 4.52 x 3.31 inch)
Weight 328 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity 5 to 95% (non-condensing)
Altitude up to 2000 m
Pollution Degree 2
Regulatory Approvals
Safety UL 61010-1, UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF IE-SW-EL08-6TX-2SC IE-SW-EL08-6TX-2SCS
Time 1.218.117 hrs 1.060.513 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

3

Other Weidmüller Switch manuals

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller PV Next Series User manual

Weidmüller

Weidmüller PV Next Series User manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller IE-SW-SL28M User manual

Weidmüller

Weidmüller IE-SW-SL28M User manual

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Popular Switch manuals by other brands

Fujitsu XG0224 Safety and installation guide

Fujitsu

Fujitsu XG0224 Safety and installation guide

Edimax 5/8 Ports Desktop Quick installation guide

Edimax

Edimax 5/8 Ports Desktop Quick installation guide

pass & seymour RW500U installation instructions

pass & seymour

pass & seymour RW500U installation instructions

Asante FriendlyNET Wireless USB Adapter Quick installation guide

Asante

Asante FriendlyNET Wireless USB Adapter Quick installation guide

3Com DUA1698 user guide

3Com

3Com DUA1698 user guide

Eaton SOL30-SAFETY/2M Series Instruction leaflet

Eaton

Eaton SOL30-SAFETY/2M Series Instruction leaflet

NETGEAR ProSafe GS110T Installationsanleitung

NETGEAR

NETGEAR ProSafe GS110T Installationsanleitung

Honeywell 10260 Series Replacement/Upgrade Instructions

Honeywell

Honeywell 10260 Series Replacement/Upgrade Instructions

MicroNet SP1659P user manual

MicroNet

MicroNet SP1659P user manual

Vega VEGACAP 65 operating instructions

Vega

Vega VEGACAP 65 operating instructions

NTI UNIMUX-HD4K-x Installation and operation manual

NTI

NTI UNIMUX-HD4K-x Installation and operation manual

Dell PowerConnect B-FCXs user guide

Dell

Dell PowerConnect B-FCXs user guide

Kinivo K301 user manual

Kinivo

Kinivo K301 user manual

H3C S9500 Series Operation manual

H3C

H3C S9500 Series Operation manual

3Com SuperStack 3 4950 Getting started guide

3Com

3Com SuperStack 3 4950 Getting started guide

Luminex DMX512-A 2.10 HUB user guide

Luminex

Luminex DMX512-A 2.10 HUB user guide

ZyXEL Communications MS-7206 manual

ZyXEL Communications

ZyXEL Communications MS-7206 manual

FM Systems IPX Instruction book

FM Systems

FM Systems IPX Instruction book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.