Hardware Installation Guide
Managed Gigabit Ethernet PoE Switch
IE-SW-AL06M-4GTPoE-2GESFP (Part No. 2682430000)
1. Introduction
Ethernet Switches from Weidmüller are designed for industrial applications and fitted with a
robust housing. To ensure reliable, error-free operation, and to prevent damage or injury, please
read the operating instructions, all safety information provided in this document and any other
safety information that were supplied with the product.
2. Safety notice
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the product
label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low Voltage
Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for clean
up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon
sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient temperature is
not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la température
ambiante ne doit pas dépasser 75 degrés C.
Intended use: The device is intended for the realization of communication networks within an
industrial environment, it is intended to be used in a restricted access location. The device may only
be used within the scope of the specified technical data. The device is intended to be mounted to a
well-grounded mounting surface, such as a metal panel. Any other use may result in unintentional
malfunction and damage. Observing the documentation is part of the intended use.
Environmental conditions: This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not
exceed the temperature given in the technical data. Also make sure that the air flow will not be
compromised by other devices. Ensure that the mounted and wired device is not exposed to any
mechanical stress.
FCC compliance: This device complies with part 15 of FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Serial console cable
Protective caps for RJ45 ports
4. Panel Layouts
1. Terminal block for power input (PWR1 /
PWR2) and fault relay (output)
2. Power Input LEDs (PWR1 / PWR2)
3. Fault LED (Power fault / Port link loss)
4. Status LED Ring Master
5. Status LED Ring Enabled
6. LAN port PoE Indicators
7. Reset Button
8. 4 x 10/100/1000BASE-T(X) Ports
9. LAN port Link/Activity LED
10. LED for speed indication (Green = 1000 Mbps,
Amber = 100 Mbps, Off = 10 Mbps)
11. Article Number
12. Serial Console Port (115200 Baud, 8 Data bit,
No Parity, 1 Stop bit, No Flow Control)
13. 2 x 100/1000BASE-X Ports (SFP Slots)
14. SFP port G6 Link/Activity LED
15. SFP port G5 Link/Activity LED
16. Grounding screw / Frame ground (Note: The
shielding ground of the LAN port is electrically
connected to the grounding screw)
17. DIN-Rail kit
5. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Place the mounting clip from
above onto the mounting rail.
STEP 2: Press the device against the
DIN rail until the fastening element
engages on the mounting rail.
To remove the Ethernet Switch from
the DIN-rail pull down the latch with a
screwdriver then move the device
away from the DIN rail and lift it up.
6. Mounting Dimensions (units = mm)
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
-
the ground connection from the ground screw to the grounding surface prior to
connecting devices.
- This product is intended to be mounted to a well-grounded mounting surface,
such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected to the
ground connection (screw).
8. Wiring Redundant Power Inputs and Fault Alarm Relay
The switch supports redundant power supply inputs and provides a fault alarm relay for
detecting the user-configurable failure events
Interruption of Power 1 or Power 2 and
Link Loss of Ethernet Ports.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
4 5 6 V1.2 / 2022-03-29
Refer to illustration below for correct wiring.
Behavior of fault alarm relay (can be triggered by configurable events power failure or
port link down):
Relay contact is closed if the device is powered-off.
Relay contact is open if the device is powered-on and no alarm conditions exist (neither
Power Failure Alarms nor Port Link Loss Alarms are activated (Web menu Warnings 
Fault Relay Alarm).
Relay contact closes if any of an activated alarm condition happens.
9. Communication Connections
Switch IE-SW-AL06M-4GTPoE-2GESFP is equipped with the following communication
interfaces:
4 x 10/100/1000BASE-T(X) PoE ports (P.S.E.)
2 x 100/1000BASE-X Ports (SFP Slots)
9.1 10/100/1000BASE-T(X) PoE ports (P.S.E)
For communication without PoE sourcing the switch supports auto negotiation speed,
Full/Half duplex mode and auto MDI/MDI-X connection, means automatic setting of pinouts
for both MDI ports (NIC-type) or MDI-X ports (HUB/Switch-type).
In case of active PoE sourcing the switch uses the pinout of “Alternative A, MDI mode” of
802.3af/802.3at standards. Please see the details in the following table.
Pinouts 10/100/1000BASE-T(X) PoE ports (P.S.E)
8-Pin RJ45
Port
10/100 BASE-T(X) MDI/MDI-X 1000BASE-T MDI/MDI-X
Pin
No. MDI port MDI-X port Pin
No. MDI port MDI-X port
1 TD+(transmit) with
PoE Power + RD+(receive) 1 BI_DA+ with
PoE Power + BI_DB+
2 TD-(transmit) with
PoE Power + RD-(receive) 2 BI_DA- with
PoE Power + BI_DB-
3 RD+(receive) with
PoE Power - TD+(transmit) 3 BI_DB+ with
PoE Power - BI_DA+
4 Not used Not used 4 BI_DC+ BI_DD+
5 Not used Not used 5 BI_DC- BI_DD-
6 RD-(receive) with
PoE Power - TD-(transmit) 6 BI_DB- with
PoE Power - BI_DA-
7 Not used Not used 7 BI_DD+ BI_DC+
8 Not used Not used 8 BI_DD- BI_DC-
9.2 100/1000BASE-X SFP fiber optic port
The 100/1000BASE SFP type slots require either a 100BASE SFP or a 1000BASE SFP fiber
transceiver (mini-GBIC) to work properly. Please only use SFP modules and cables that are
compatible with each other to establish an optical connection.
LC-Port Pinouts: LC-Port to LC-Port Cable Wiring:
For a LC-Port with separate Transmit and Receive Port please remember to connect the Tx
(transmit) port of Device-1 to the Rx (receive) port of Device-2, and the Rx (receive) port of
Device-1 to the Tx (transmit) port of Device-2.
9.3 RS232 Console Port
The RS232 Interface with RJ45 connector can be used to access the switch console for
configuration. Additionally, it can be applied with external Backup/Restore module IE-EBR-
MODULE-RS232-ALM (Article no. 2682610000).
Pinouts Serial
Console Port:
10. User Management
10.1 Device Access (Login to Web Interface)
The Web interface of the Switch can be accessed via following factory default settings:
IP address / Netmask: 192.168.1.110 / 255.255.255.0
User name: admin
Password: Detmold
Connect the PC to any Ethernet port of the managed Switch and set the PC’s IP address to a
free one of range 192.168.1.0 / 255.255.255.0
Start a web browser and enter the IP address of the connected Switch into the browser’s
address line (http://192.168.1.110). After the appearance of prompt (login) enter the login
credentials. After confirmation of your input with "OK" the home page of the switch will be
displayed.
10.2 Reset Button (Behavior of Factory Default Settings)
Pressing < 5 seconds: Reboot the switch (Warm Start) and sets IP to Factory Default IP.
Pressing >= 5 seconds: Resets the switch configuration to Factory Default Settings.
Note: Behavior of reset button can be configured in the Web Interface (Menu Factory Default).
11. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of each
LED is described in the table below.
LED Color Status Description
PWR1 Green On Power is supplied to power input PWR1.
PWR2 Green On Power is supplied to power input PWR2.
R-MSTR
(Ring Master) Green On Is Ring Master of an enabled O-Ring.
Ring Green On O-Ring redundancy is enabled.
Blinking Ring structure is broken (No redundancy).
PoE Green On Power supplied over Ethernet
LNK/ACT
(Ports G1-G4) Green
On Port link is active.
Off Port link is inactive.
Blinking Data is transmitted.
10/100/1000M
(Ports G1-G4)
Green /
Amber
Green Port speed is set to 1000 Mbps.
Amber Port speed is set to 100 Mbps.
Off Port speed is set to 10 Mbps.
LNK/ACT
(SFP Ports
G5-G6)
Green
On Port link is active.
OFF Port link is inactive.
Blinking Data is transmitted.
FAULT Amber On
Fault Relay indication for Power failure and Port link loss.
12. Disposal Information
Observe the notes for proper disposal of the
product. You can find the notes here:
www.weidmueller.com/disposal.
13. Specifications
Technology
Ethernet Standards
IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-TX and 100BASE-FX
IEEE 802.3ab for 1000BASE-T
IEEE 802.3z for 1000BaseX
IEEE 802.3x for flow control
IEEE 802.3af/at for Power over Ethernet
IEEE 802.3ad for port trunk with LACP
IEEE 802.1D for STP (Spanning Tree protocol)
IEEE 802.1w for RSTP (Rapid Spanning Tree protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
Processing Type Store and Forward
MAC Table size 8K
Packet buffer size 4 Mbit
Backplane bandwidth 12 Gbps
Jumbo frame support Up to 9.6 kBytes
Interfaces
RJ45 Ports 10/100/1000BASE-T(X) PoE ports (P.S.E.) compliant to PoE
standard IEEE 802.3af/at
Fiber optic ports 2 x 100/1000BASE-X SFP slots
RS232 Console Port RS232 Interface with RJ45 connector for Console access and
useable with external Backup/Restore module
LED Indicators PWR1, PWR2 (Power), Fault (Relay), Ring Master, Ring
Status, Port Link/Activity/Speed, PoE
Relay Contact Max. 1A @ 24 V DC for Power Failure and Port Link Loss
Power
Input Voltage 12/24/48 V DC (12 - 57 V DC), 2 redundant inputs
Input Current
(with PD consumption)
6.6 A @ 12 V DC; 5.68 A @ 24 V DC; 2.76 A @ 48 V DC
Connection One removable 6-pin terminal block, Wiring cable 12-24AWG
Overload Current Protect. Present
Reverse Polarity Protect. Present
PoE
Total power budget 60 W @ 12 – <24 V DC; 120 W @ 24 - 57 V DC
PoE Pinout Mode A: Pin 1, 2 (V+); Pin 3, 6 (V-); Alternative A; MDI
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 54.3 x 145.1 x 108.5 mm (2.14 x 5.71 x 4.27 inch)
Weight 678 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Operating Altitude Up to 2000 m
Regulatory Approvals
Safety UL 61010-1; UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 V
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time 495.624 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

1

Other Weidmüller Switch manuals

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller

Weidmüller IE-SW-AL08M-8TX Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller

Weidmüller IE-SW-AL05M-5TX User manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller PV Next Series User manual

Weidmüller

Weidmüller PV Next Series User manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-SL28M User manual

Weidmüller

Weidmüller IE-SW-SL28M User manual

Popular Switch manuals by other brands

Vetra MegaSwitch VIP-602 Series User instructions

Vetra

Vetra MegaSwitch VIP-602 Series User instructions

Marmitek SMM31 user manual

Marmitek

Marmitek SMM31 user manual

3Com 3CRS48G-24-91 datasheet

3Com

3Com 3CRS48G-24-91 datasheet

ATEN CS-72E user manual

ATEN

ATEN CS-72E user manual

Unipoe PM3020FSNL V3 user manual

Unipoe

Unipoe PM3020FSNL V3 user manual

TRENDnet TEG-S5 Specifications

TRENDnet

TRENDnet TEG-S5 Specifications

ESC ELMARK ELFS10 manual

ESC

ESC ELMARK ELFS10 manual

Tenda TEH1208 user manual

Tenda

Tenda TEH1208 user manual

Raritan II user manual

Raritan

Raritan II user manual

Pilz ma1.4p-52 operating instructions

Pilz

Pilz ma1.4p-52 operating instructions

Emerson Rosemount 2535 quick start guide

Emerson

Emerson Rosemount 2535 quick start guide

Manhattan 162272 instructions

Manhattan

Manhattan 162272 instructions

Minicom Smart CAT5 Switch 16 IP operating guide

Minicom

Minicom Smart CAT5 Switch 16 IP operating guide

Extreme Networks Summit 200-24 Installation and user guide

Extreme Networks

Extreme Networks Summit 200-24 Installation and user guide

AMBIENTECH TONE-WS Series installation instructions

AMBIENTECH

AMBIENTECH TONE-WS Series installation instructions

Gefen DVI-441 user manual

Gefen

Gefen DVI-441 user manual

Pakedge Device & Software SE-USB1-EP quick start guide

Pakedge Device & Software

Pakedge Device & Software SE-USB1-EP quick start guide

SIIG US22 Series Quick installation guide

SIIG

SIIG US22 Series Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.