Hardware Installation Guide
Unmanaged Fast Ethernet Switches
IE-SW-EL16-14TX-2FESFP (Part No. 2682160000)
1. Introduction
Ethernet Switches from Weidmüller are designed with a very compact housing size and
are fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided in
this document and any other safety information that were supplied with the product.
2. Safety notice
Switch off the electrical power before removing the power connection!
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas dépasser 75 degrés C.
Intended use
The device is intended for the realization of communication networks within an industrial
environment, it is intended to be used in a restricted access location. The device may only
be used within the scope of the specified technical data. The device is intended to be
mounted to a well-grounded mounting surface, such as a metal panel. Any other use may
result in unintentional malfunction and damage. Observing the documentation is part of the
intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during
operation will not exceed the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Protective caps for RJ45 ports and SFP ports
4. Panel Layouts
1. Terminal block for power input PWR1 /
PWR2
2. Grounding screw / Frame ground
(Note: The shielding ground of the LAN
port is electrically connected to the
grounding screw)
3. Power input LEDs (PWR1 / PWR2)
4. LAN port Link/Activity LED
5. LAN port Speed LED (Amber = 100
Mbps, Off = 10Mbps)
6. Article Number
7. SFP Port Link/Activity LED
8. SFP Slot 1000Base(X)
9. 10/100Base-T(X) ports
10. DIN-rail kit
5. Mounting Dimensions
(units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Insert the top of the
DIN-Rail into the slot just
below the stiff metal spring.
STEP 2: The DIN-Rail
attachment unit will snap into
place as shown below.
To remove the DIN-rail from the Ethernet Switch, simply reverse Steps 1 and 2.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding
surface prior to connecting devices.
- This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected
to the ground connection (screw).
4 5 6 V1.0 / 2020-11-02
8. Wiring Redundant Power Inputs
The switch supports redundant power supply inputs. For wiring via 6-pin terminal
connector please refer to below illustration.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
9. Communication Connections
Switch IE-SW-EL16-14TX-2FESFP is equipped with following communication interfaces:
14x 10/100Base-T(X) ports
2x 100Base-FX SFP slots to be used with SFP Transceivers (mini-GBIC
Please only use cables suitable for the respective type of communication and ensure that
signals are protected from possible interference.
9.1 10/100Base T(X) RJ45 Ports
The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to connect
to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) ports and
MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-schemes are
supported (Automatic crossover function).
10/100Base T(X) RJ45 Pinouts
MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45
Pin Signal Pin Signal
1 Tx+ 1 Rx+
2 Tx- 2 Rx-
3 Rx+ 3 Tx+
6 Rx- 6 Tx-
9.2 100Base-FX SFP (mini-GBIC) Fiber Port
The 100Base-FX type slots, require 100Base-FX SFP (mini-GBIC) fiber transceivers to
work properly. Weidmüller provides transceiver models for various distance requirements.
Please only use SFP modules and cables that are compatible with each other to establish
an optical connection.
LC-Port with separate Transmit and Receive Port:
Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device
II, and the Rx (receive) port of device I to the Tx (transmit) port of device I
LC-Port Pinouts LC-Port to LC-Port Cable Wiring
Note about possible loss of data packages in case of “Duplex mismatching”
If the switch’s auto-negotiation port is connected to a non-negotiating device,
then the switch will set its port transmission speed same as the connected
device but is unable to correctly detect the duplex mode.
As result the port is set to the correct speed but is using always the half duplex
mode as required by the IEEE 802.3u standard in such cases.
For correct transmission, the non-negotiating port must be set to half-duplex
mode (speed can be either 10 Mbps or 100 Mbps, it always will be recognized
automatically by an Auto-Negotiation-Device).
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green
On Power is being supplied to power input
PWR1.
Off Power is not being supplied to power input
PWR1.
PWR2 Green
On Power is being supplied to power input
PWR2.
Off Power is not being supplied to power input
PWR2.
LNK/ACT
(RJ45 LAN
Ports)
Green
On Port link is active.
Off Port link is inactive.
Blinking Transmitting data.
10/100M
(RJ45 LAN
Ports)
Amber
On Port speed is 100 Mbps.
Off Port speed is 10 Mbps.
100M
(Fiber Port 15-
16)
Green
On Port link is active.
Off Port link is inactive.
Blinking Transmitting data.
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100BaseTX and 100BaseFX
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size 4K
Packet buffer size 2.75 Mbit
Backplane bandwidth 3.2 Gbps
Interfaces
RJ45 Ports 10/100BaseT(X) auto negotiation speed, Full/Half duplex
mode and auto MDI/MDI-X connection
Fiber optic Port 100BaseSFP slot
LED Indicators PWR1, PWR2 (Power), LAN Port Link/Activity and Port
speed, SFP Port Link/Activity
Power
Input Voltage 24 V DC (12 - 48 V DC) ,2 redundant inputs
Input Current @24 VDC 0.34 A
Connection One removable 6-pin terminal block, Wiring cable 12-24AWG
Overload Current
Protection Present
Reverse Polarity
Protection Present
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 74 x 170 x 140 mm (2.91 x 6.69 x 5.51 in)
Weight 1120 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity 5 to 95% (non-condensing)
Altitude up to 2000 m
Regulatory Approvals
Safety UL 61010-1; UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time 719.800 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

1

Other Weidmüller Switch manuals

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL08M-8GTPoE Manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8PoE Manual

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller IE-SW-SL28M User manual

Weidmüller

Weidmüller IE-SW-SL28M User manual

Popular Switch manuals by other brands

ZILR LUMIN user manual

ZILR

ZILR LUMIN user manual

Garland INT10G12MSFE-5 user guide

Garland

Garland INT10G12MSFE-5 user guide

SIIG CE-KV0G11-S1 user manual

SIIG

SIIG CE-KV0G11-S1 user manual

Siemens RUGGEDCOM RX1500 user guide

Siemens

Siemens RUGGEDCOM RX1500 user guide

H3C S12500X-AF Series Configuration Examples

H3C

H3C S12500X-AF Series Configuration Examples

Kramer VP-23DS user manual

Kramer

Kramer VP-23DS user manual

CableCreation CD0395 manual

CableCreation

CableCreation CD0395 manual

United Electric Controls 117 Series Installation and maintenance instructions

United Electric Controls

United Electric Controls 117 Series Installation and maintenance instructions

Avaya ERS 3500 Series Regulatory information

Avaya

Avaya ERS 3500 Series Regulatory information

Axis T8604 installation guide

Axis

Axis T8604 installation guide

MikroTik CRS326-24G-2S+IN manual

MikroTik

MikroTik CRS326-24G-2S+IN manual

Moxa Technologies EtherDevice EDS-828 Series Quick installation guide

Moxa Technologies

Moxa Technologies EtherDevice EDS-828 Series Quick installation guide

Mitel ST24A Quick install guide

Mitel

Mitel ST24A Quick install guide

IOGear GCS1808i quick start guide

IOGear

IOGear GCS1808i quick start guide

Compaq Storageworks SAN Switch 8 Installation and hardware guide

Compaq Storageworks

Compaq Storageworks SAN Switch 8 Installation and hardware guide

DeviceWell SDI 10-Screen Multiview user manual

DeviceWell

DeviceWell SDI 10-Screen Multiview user manual

Acnodes KV801 user manual

Acnodes

Acnodes KV801 user manual

D-Link DES-7000 Series user manual

D-Link

D-Link DES-7000 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.