4 5 6 Edition 4 / 08-2020
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding surface
prior to connecting devices.
- This product is intended to be mounted to a well-grounded mounting
surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected to the
ground connection (screw).
8. Wiring the Redundant Power Inputs
The switch supports redundant power supply inputs which are located on the 4-pin
terminal block. Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
9. Communication Connections
Switch IE-SW-EL05-5GT is equipped with following communication interfaces:
5x 10/100/1000Base-T(X) ports
Switch IE-SW-EL08-8GT-MINI is equipped with following communication interfaces:
8x 10/100/1000Base-T(X) ports
Please only use cables suitable for the respective type of communication and ensure that
signals are protected from possible interference.
9.1 10/100/1000Base T(X) RJ45 Ports
The 10/100/1000BaseT(X) ports located on Ethernet Switch’s front panel are used to
connect to Ethernet-enabled devices. Below we show pinouts for both MDI (NIC-type) ports
and MDI-X (HUB/Switch-type) ports. Auto MDI-X ensures that both wiring-schemes are
supported (Automatic crossover function).
Pinouts 10/100/1000Base T(X) RJ45
8-Pin RJ45
Port
10/100 Base-T(X) MDI/MDI-X 1000Base-T MDI/MDI-X
Pin No. MDI port MDI-X port Pin No. MDI port MDI-X port
1 TD+(transmit) RD+(receive) 1 BI_DA+ BI_DB+
2 TD-(transmit) RD-(receive) 2 BI_DA- BI_DB-
3 RD+(receive) TD+(transmit) 3 BI_DB+ BI_DA+
4 Not used Not used 4 BI_DC+ BI_DD+
5 Not used Not used 5 BI_DC- BI_DD-
6 RD-(receive) TD-(transmit) 6 BI_DB- BI_DA-
7 Not used Not used 7 BI_DD+ BI_DC+
8 Not used Not used 8 BI_DD- BI_DC-
Note about possible loss of data packages in case of “Duplex
mismatching”
If the switch’s auto-negotiation port is connected to a non-negotiating device,
then the switch will set its port transmission speed same as the connected
device but is unable to correctly detect the duplex mode.
As result the port is set to the correct speed but is using always the half
duplex mode as required by the IEEE 802.3u standard in such cases.
For correct transmission, the non-negotiating port must be set to half-duplex
mode (speed can be either 10 Mbps, 100 Mbps or 1000 Mbps, it always will
be recognized automatically by an Auto-Negotiation-Device).
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green
On Power is being supplied to power input PWR1.
Off Power is not being supplied to power input
PWR1.
PWR2 Green
On Power is being supplied to power input PWR2.
Off Power is not being supplied to power input
PWR2.
LNK/ACT Green
On Port’s link is active.
Off Port’s link is inactive.
Blinking Transmitting data.
10/100/1000M Amber
/ Green
Green Port speed 1000 Mbps
Amber Port speed 100 Mbps
Off Port speed 10 Mbps
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size 4K
Packet buffer size IE-SW-EL05-5GT: 1 Mbit
IE-SW-EL08-8GT-MINI: 1.5 Mbit
Backplane
bandwidth
IE-SW-EL05-5GT: 10 Gbps
IE-SW-EL08-8GT-MINI: 16 Gbps
Jumbo frame
support
IE-SW-EL05-5GT: up to 9.72 KB
IE-SW-EL08-8GT-MINI: up to 9 KB
Interface
RJ45 Ports 10/100/1000Base-T(X) auto negotiation speed, F/H duplex mode
and auto MDI/MDI-X connection
LED Indicators PWR1, PWR2 (Power), Port Link/Activity, Port Speed
Power
Input Voltage 24 V DC (12 - 48 V DC), 2 redundant inputs
Input Current
@24 VDC
IE-SW-EL05-5GT: 0.14 A
IE-SW-EL08-8GT-MINI: 0.17 A
Connection One removable 4-pin terminal block, Wiring cable 12-24AWG
Overload Current
Protection Present
Reverse Polarity
Protection Present
Physical Characteristics
Housing IP30 protection, metal case
Dimension
(W x H x D)
IE-SW-EL05-5GT: 26.1 x 95 x 70 mm (1.03 x 3.74 x 2.76 in)
IE-SW-EL08-8GT-MINI: 41 x 95 x 90 mm (1.61 x 3.74 x 3.54 in)
Weight IE-SW-EL05-5GT: 222 g
IE-SW-EL08-8GT-MINI: 372 g
Installation DIN-rail
Environmental conditions
Operating
Temperature -40 to 75°C (-40 to 167°F)
Storage
Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity 5 to 95% (non-condensing)
Altitude up to 2000 m
Pollution Degree 2
Regulatory Approvals
Safety UL 61010-1, UL 61010-2-201
EMS
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD:
IE-SW-EL05-5GT: Contact: 4 kV; Air: 8 kV
IE-SW-EL08-8GT-MINI: Contact: 6 kV; Air: 10 kV
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m
IEC 61000-4-4 EFT:
IE-SW-EL05-5GT: Power: 0.5 kV; Signal: 0.5 kV
IE-SW-EL08-8GT-MINI: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge:
IE-SW-EL05-5GT: Power: 0.5 kV; Signal (RJ45): 1 kV
IE-SW-EL08-8GT-MINI: Power: 1 kV; Signal (RJ45): 4 kV
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time IE-SW-EL05-5GT: 2.556.319 hrs
IE-SW-EL08-8GT-MINI: 1.742.238 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com