Hardware Installation Guide
Unmanaged Fast Ethernet PoE Switches
IE-SW-EL08-8PoE (Part No. 2682380000)
IE-SW-EL06-4PoE-2SC (Part No. 2682390000)
1. Introduction
Ethernet Switches from Weidmüller are designed with a very compact housing size and
are fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided in
this document and any other safety information that were supplied with the product.
2. Safety notice
Switch off the electrical power before removing the power connection!
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas dépasser 75 degrés C.
Intended use
The device is intended for the realization of communication networks within an industrial environment, it is
intended to be used in a restricted access location. The device may only be used within the scope of the
specified technical data. The device is intended to be mounted to a well-grounded mounting surface, such as
a metal panel. Any other use may result in unintentional malfunction and damage. Observing the
documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will not exceed
the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Protective caps for RJ45 and Fiber optic ports
4. Panel Layouts
1. Terminal block for power
input PWR1/PWR2 and
Power failure relay (output)
2. Grounding screw / Frame
ground (Note: The shielding
ground of the LAN port is
electrically connected to the
grounding screw)
3. Power Input LEDs (PWR1 /
PWR2)
4. Power Fault LED (PWR1 /
PWR2 fault)
5. 100BaseFX port (Multi-
mode, SC Connector)
6. Fiber port Link/Activity LED‘s
7. 10/100Base-T(X) PoE ports
(P.S.E)
8. Article Number
9. LED RJ45 port Link/Activity
10. LED for PoE power injection
11. DIP switch for enabling /
disabling Power Fault relay
SW1 ON: Switches relay if
power 1 fails
SW2 ON: Switch relay if
power 2 fails
12. DIN-Rail kit
5. Mounting Dimensions
(units = mm)
6. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Insert the top of the
DIN-Rail into the slot just below
the stiff metal spring.
STEP 2: The DIN-Rail
attachment unit will snap into
place as shown below.
To remove the DIN-rail from the Ethernet Switch, simply reverse Steps 1 and 2.
7. Grounding Ethernet Switch
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- the ground connection from the ground screw to the grounding
surface prior to connecting devices.
- This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected
to the ground connection (screw).
4 5 6 V1.0 / 2020-10-29
8. Wiring Redundant Power Inputs and Power Fault
Relay
The switch supports redundant power supply inputs and provides a power fault relay
which can be used for alarming in case of interruption of Power 1 or Power 2 on the 6-pin
terminal block. Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque
value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-
24AWG. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
oLa température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL
61010-1 or 61010-2-201.
Note about behavior of power failure relay:
Relay contact is closed if the device is powered-off.
Relay contact always is open if the device is powered either by PWR1 or PWR2 and
if DIP switches 1 and 2 for power control are set to off.
Relay contact closes if DIP switch 1 is set to ON and PWR1 fails.
Relay contact closes if DIP switch 2 is set to ON and PWR2 fails.
9. Communication Connections
Switch IE-SW-EL08-8PoE is equipped with the following communication interfaces:
8x 10/100Base-T(X) PoE ports (P.S.E)
Switch IE-SW-EL06-4PoE-2SC is equipped with following communication interfaces:
4x 10/100Base-T(X) PoE ports (P.S.E)
2x 100BaseFX port with SC Connector (Multi-mode)
Please only use cables suitable for the respective type of communication and ensure that
signals are protected from possible interference.
9.1 10/100Base T(X) PoE Ports (P.S.E.)
For communication without PoE sourcing the switch supports auto negotiation speed,
Full/Half duplex mode and auto MDI/MDI-X connection, means automatic setting of
pinouts for both MDI ports (NIC-type) or MDI-X ports (HUB/Switch-type). In case of active
PoE sourcing the switch uses the pinout of “Alternative A, MDI mode” of 802.3af/802.3at
standards. Please see the details in the following table.
10/100Base T(X) RJ45 Pinouts (P.S.E. Port)
MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45
Pin Signal Pin Signal
1 Tx+ with PoE Power + 1 Rx+
2 Tx- with PoE Power + 2 Rx-
3 Rx+ with PoE Power - 3 Tx+
6 Rx- with PoE Power - 6 Tx-
9.2 100BaseFX Port (only IE-SW-EL06-4PoE-2SC)
The switch is equipped with 2 * 100BaseFX Fiber optic ports with SC connectors.
For connecting fiber ports between 2 devices consider to connect wire Tx (transmit) of
device 1 to wire Rx (receive) of device 2, and vice versa. Remember that fiber optic
connections generally are using the full-duplex transmission mode.
SC-Port Pinouts SC-Port to SC-Port Cable Wiring
10. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green On Power is being supplied to power input PWR1.
Off Power is not being supplied to power input PWR1.
PWR2 Green On Power is being supplied to power input PWR2.
Off Power is not being supplied to power input PWR2.
FAULT Amber On Indicates PWR1 or PWR2 fault (if corresponding
DIP switches are set to ON).
Off If DIP switches are set to OFF or no power failure.
LNK/ACT Green On Link of RJ45 Port is active.
Off Link of RJ45 Port is inactive.
100M Green On Link of Fiber Port is active.
Off Link of Fiber Port is inactive.
PoE
Active Green On PoE power injection is active.
Off PoE power injection is inactive.
11. Specifications
Technology
Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3af/at for Power over Ethernet
IEEE 802.3x flow control
Processing Type Store and Forward
MAC Table size 1K
Packet buffer size 448 Kbit
Backplane bandwidth IE-SW-EL06-4PoE-2SC: 1.2 Gbps
IE-SW-EL08-8PoE: 1.6 Gbps
Interfaces
RJ45 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex
mode and auto MDI/MDI-X connection
LED Indicators PWR1, PWR2 (Power), Power Fault, Port Link/Activity,
Port Speed, PoE
Relay Contact Max. 1A @ 24 VDC
DIP Switches Enabling/Disabling relay alarm for PWR1/PWR2 failure
Fiber Ports IE-SW-EL06-4PoE-2SC
Fiber Ports number 2
Fiber Ports standard 100Base-FX
Fiber Mode Multi-mode
Fiber Diameter (μm) 62.5/125 μm; 50/125 μm
Connector Type SC-Duplex
Typical Distance (km) 2 km
Power
Input Voltage IE-SW-EL08-8PoE:
12/24/48 V DC (12 - 57 V DC), 2 redundant inputs
IE-SW-EL06-4PoE-2SC:
24/48 V DC (24 - 57 V DC), 2 redundant inputs
Input Current @24 V DC
(with PD consumption)
IE-SW-EL08-8PoE: 5.74 A
IE-SW-EL06-4PoE-2SC: 2.8 A
Connection One removable 6-pin terminal block, Wiring cable 12-
24AWG
Overload Current Protection
Present
Reverse Polarity Protection Present
PoE
Total PoE power budget
IE-SW-EL08-8PoE:
60 W @ 12 – 23 V DC; 120 W @ 24 -57 V DC
IE-SW-EL06-4PoE-2SC:
60 W @ 24 – 50 V DC; 120 W @ 50 -57 V DC
PoE Pinout Mode A: Pin 1, 2 (V+); Pin 3, 6 (V-); Alternative A; MDI
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 41 x 144.3 x 94.9 mm (1.61 x 5.68 x 3.74 in)
Weight IE-SW-EL08-8PoE: 580 g
IE-SW-EL06-4PoE-2SC: 435 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Operating Altitude up to 2000 m
Regulatory Approvals
Safety UL 61010-1, UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time IE-SW-EL08-8PoE: 744.974 hrs
IE-SW-EL06-4PoE-2SC: 538.904 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

3

Other Weidmüller Switch manuals

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller

Weidmüller IE-SW-AL24M-24TX Manual

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller

Weidmüller IE-SW-EL08-6TX-2SC Manual

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller

Weidmüller Gigabit Advanced IE-SW-AL06M-4GTPoE-2GESFP Manual

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller

Weidmüller ValueLine IE-SW-VL08-GT Series Manual

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL08M Series Manual

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller

Weidmüller Substation IE-SW-SL26M-24TX-2GC User manual

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT User manual

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller

Weidmüller IE-SW-EL16-14TX-2FESFP Manual

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller

Weidmüller IE-SW-EL24-24TX Manual

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller

Weidmüller IE-SW-EL08-8GTPoE Manual

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-EL18-16TX-2GC Manual

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller

Weidmüller Basic Line IE-SW-BL05-4GTPoE Series Manual

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller

Weidmüller IE-SW-EL05-5GT Manual

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller

Weidmüller IE-SW-BL05-5GT Manual

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GTPoE-2GESFP Manual

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller

Weidmüller IE-SW-EL10-8GT-2GESFP Manual

Weidmüller 2682340000 Manual

Weidmüller

Weidmüller 2682340000 Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller

Weidmüller Value Line IE-SW-VL05M Series Manual

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller

Weidmüller IE-SW-EL05-5TX Manual

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller

Weidmüller IE-SW-EL08-8GT Manual

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-8GT Manual

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller

Weidmüller IE-SW-BL05-4GT-1GS Manual

Weidmüller Premium Line IE-SW-PL10M Series Manual

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Manual

Popular Switch manuals by other brands

Cudy GS105D Quick installation guide

Cudy

Cudy GS105D Quick installation guide

Axis T8344 user manual

Axis

Axis T8344 user manual

D-Link DXS-3600-32S reference guide

D-Link

D-Link DXS-3600-32S reference guide

Tributaries HX410 manual

Tributaries

Tributaries HX410 manual

H3C S3100 Series Operation manual product overview

H3C

H3C S3100 Series Operation manual product overview

e+p UHD 151 manual

e+p

e+p UHD 151 manual

HP AA-RW20A-TE user guide

HP

HP AA-RW20A-TE user guide

Gude Expert Power Control NET 8x 8211 manual

Gude

Gude Expert Power Control NET 8x 8211 manual

Extron electronics System 5cr user manual

Extron electronics

Extron electronics System 5cr user manual

IFM Electronic AL3100 operating instructions

IFM Electronic

IFM Electronic AL3100 operating instructions

Lindy 32529 user manual

Lindy

Lindy 32529 user manual

D-Link DHP-342 user manual

D-Link

D-Link DHP-342 user manual

ATEN CL5808 user manual

ATEN

ATEN CL5808 user manual

Aventics PE6 operating instructions

Aventics

Aventics PE6 operating instructions

ifs NS3550-8T-2S-V2 Quick installation guide

ifs

ifs NS3550-8T-2S-V2 Quick installation guide

Sky Hub Setup guide

Sky

Sky Hub Setup guide

Balluff BNI IOL-727-S51-P012 Assembly instructions

Balluff

Balluff BNI IOL-727-S51-P012 Assembly instructions

Siemens 7XV5550-0xA00 Series manual

Siemens

Siemens 7XV5550-0xA00 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.