µ
WMF coffeemachines
WMF 5000 S planning information –Easy Milk
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
Optional: cut-out for under
machine cooler milk hose
Optional: cut-out for
grounds through counter
On site
On site
3x1,5 mm2, length appr. 1m
or
Optional: vending unit
Card reader width 130 mm
Coin Checker and coin
changer 105 mm
Card reader and coin changer
height 500 mm
Coin Checker height 502 mm
Optional feet
100 mm
Optional: pipe for
grounds disposal
70 x 120 x 250 mm
(extension with second
pipe possible)
5x2,5 mm2, length appr. 2,5m
Water and power connection
Optional:
Area for counter cut out connection
minimum 50x60 or Ø70
Placement in hatched area is freely
selectable
Waste water connection
Optional:
Area for counter cut out connection
minimum 50x60 or Ø70
µ
WMF coffeemachines
WMF 5000 S planning information –Easy Milk
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water and drainage connections at the customer‘s premises
is to be arranged by the machine owner / operator. The work must be carried out
by authorised installation technicians in compliance with general, country-specific and local regulations. The
WMF service engineers may only connect the coffee machine to existing prepared
connection points. WMF Service is neither authorised nor responsible for carrying out any on-site installation
work prior to connection. The potential equalisation terminal is installed by WMF Service if needed
Dimensions
and empty
weight
Width
Height
Depth
Clearance heights
Weight
325 mm
706 mm
590 mm
66 –171 mm (Easy Milk)
Approx. 37 kg (depending on the model)
Water supply Water supply line
Inlet temperature
Water drain tube
(optional)
3/8 inch hose connector with mains tap, and filter
with 0.08 mm mesh size, on site. At least 0.2 MPa (2 bar) flow pressure
at 2 l/min (standard). Maximum 0.6 MPa (6 bar).
Maximum 35 °C.
Tube a minimum of DN 19, minimum downward slope
of 2 cm/m
For use at
altitude above
NN
<2000m
Electrical data Nominal power
rating
2.75 –3.25 kW 5.9 –7.1 kW
Power supply 220–240 V
50 / 60 Hz (1 / N / PE)
380–415 V
50 / 60 Hz (3 / N / PE)
Degree of
protection
IP X0
Protection Class I
Installation
Clearance
For operating, service, and safety reasons the machine should be installed with a clearance
from the building or non-WMF components of not less than 50 mm at the sides and 60 mm
at the back. A minimum working space of 800 mm in front of the coffee machine is
recommended. Clearance of at least 200 mm above the product hopper is recommended. The
height of the installation surface above the floor is at least 850 mm. If the coffee machine
connections are to be run downwards through the counter, please make space for the lines,
which can reduce the usable space below the machine. Additional space for grounds through
counter need to be considered on site if necessary.
If the coffee machine is operated with a water filter the additional space under the machine
depending on the fitler size has to be considered. For further information see filter
instructions.
Installation
surface /
water spray
The device must be placed and leveled on a horizontal, sturdy, water-resistant, and heatproof
base. The device must not be cleaned using a water jet. The device must be installed where it
is protected against water spray. The device must not be located on a surface that is sprayed
or cleaned with a water hose, steam jets, steam cleaner, or similar devices.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
µ
WMF coffeemachines
WMF 5000 S planning information –Easy Milk
Ventilation If ventilation possibility is limited sufficient ventilation need to be provided e.g machine on feet
extension, active ventilation, additional ventilation slots/ openings in counter area. Ventilation
slots must not be covered. Under certain circumstances a forced ventilation on site is necessary
to ensure heat dissipation.
Electrical
connection
These specifications for the electrical connection and the standards quoted apply for connecting
the coffee machine in EU countries. It may be necessary to also observe additional country-
specific regulations. Outside the EU countries acceptance of the standards quoted is to be
checked by the legal entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to the currently valid IEC 364 (DIN VDE
0100). An isolated ground socket or a country-specific single-phase socket for single-phase
connection, or a 5-pole CEE / CEKON socket per EN 60309 or a country-specific multi-pole
socket for a three-phase connection, must be available near the machine. The sockets are part of
the customer‘s on-site installation.
The mains cable must not come into contact with hot surfaces. If the mains cable for this device
is damaged then it must be replaced by our service
personnel or a similarly qualified person, in order to prevent hazards.
In order to avoid possible faults from arising on our shielded data lines due to potential
equalisation currents between the devices, an additional potential equalisation unit should be
planned for devices connected to the vending system. (See EN 60309)
Water
supply and
drainage
The water supply must be located close to the machine (max. distance 800 mm). An anytime
easily accessible and sufficiently dimensioned water tap (preferably ball tap) as well as a dirt
filter with mesh size 0,080 mm must be installed below the counter in the water supply.
For connection from below through the counter a cut-out must be made in the hatched area
on-site according to drawing (see top view).
For drinking water with carbonate hardness above 5°dKH (carbonate hardness), a WMF water
filter should be fitted upstream.
If the coffee machine is connected to a drain connection, a funnel siphon must be installed in
the drain pipe.
Please observe that the free drain (funnel siphon with sheet metal angle) is fitted vertically. This
means that it must always be vertical to the water back pressure level that is reached. It must be
fitted in a way that the given gradient of the drain hoses (2%) is observed.
Additionally, the free drain must always be below the drains of the coffee machine and above
the actual drain pipe connections (HT40, HT50 or similar) with respect to its height.
To a funnel siphon with sheet metal angle max. two coffee machines with DN19 hose and black
silicone fabric hose should be connected. Other devices (dishwasher, sink etc.) should be installed
elsewhere.
The free drain incl. hoses must not be exposed to heavy tensile, pressure or torsional load.
Hereby, damage might be caused at the mechanical components of the free drain. Consequently,
its usability may get lost.
The on-site preliminary works for the drainage connection must be commissioned by the
operator of the machine. They must be carried out by concession plumbers in compliance with
the prevailing, national as well as local regulations.
The following drawings serve to illustrate the drains and do not include any other connections,
such as power or water infeed!
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
µ
WMF coffeemachines
WMF 5000 S planning information –Easy Milk
Miscellaneous Ambient
temperature
+5 °C to maximum +35 °C
(empty the water system in case of frost).
Maximum
humidity
80 % relative humidity without condensation. Do not use device outdoors.
Heat
dissipation
0.1 kWh/h standby mode
3.25 kWh/h maximum use
0.1 kWh/h standby mode
6.4kW/h maximum use
Continuous
sound
pressure level
(Lpa)
< 70 dB(A)
For more information as the instruction manual , safety data sheets and certificates , see:
http://mediacenter.wmf.com/servicecenter/
All information refers to coffee machines/ equipment as standard version. Individual solutions can differ from the
standard version.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)

Other WMF Coffee Maker manuals

WMF 9440 Series User manual

WMF

WMF 9440 Series User manual

WMF 2000 S Configuration guide

WMF

WMF 2000 S Configuration guide

WMF STELIO User manual

WMF

WMF STELIO User manual

WMF Presto 1400 Series User manual

WMF

WMF Presto 1400 Series User manual

WMF 900 User manual

WMF

WMF 900 User manual

WMF Terra User manual

WMF

WMF Terra User manual

WMF PERFECTION 800L Series User manual

WMF

WMF PERFECTION 800L Series User manual

WMF I800S User manual

WMF

WMF I800S User manual

WMF 1300 S User manual

WMF

WMF 1300 S User manual

WMF Bueno User manual

WMF

WMF Bueno User manual

WMF 5000S+ User manual

WMF

WMF 5000S+ User manual

WMF combiNation S/S4/ESeries 8600 User manual

WMF

WMF combiNation S/S4/ESeries 8600 User manual

WMF 800 User manual

WMF

WMF 800 User manual

WMF PERFECTION 800L Series User manual

WMF

WMF PERFECTION 800L Series User manual

WMF BISTRO 8000 User manual

WMF

WMF BISTRO 8000 User manual

WMF 5500 Series User manual

WMF

WMF 5500 Series User manual

WMF Filter Coffee Maker User manual

WMF

WMF Filter Coffee Maker User manual

WMF Perfection 700 Series User manual

WMF

WMF Perfection 700 Series User manual

WMF 2000 S User manual

WMF

WMF 2000 S User manual

WMF STELIO User manual

WMF

WMF STELIO User manual

WMF combiNation F 8700 Series User manual

WMF

WMF combiNation F 8700 Series User manual

WMF 1300 S Configuration guide

WMF

WMF 1300 S Configuration guide

WMF 800 User manual

WMF

WMF 800 User manual

WMF Coffee Station 58 User manual

WMF

WMF Coffee Station 58 User manual

Popular Coffee Maker manuals by other brands

MAGIMIX PIXIE 11325 ROUGE instruction manual

MAGIMIX

MAGIMIX PIXIE 11325 ROUGE instruction manual

Conti TOUTAUTO 388 Installation & operation

Conti

Conti TOUTAUTO 388 Installation & operation

LAVAZZA Jolie plus quick start guide

LAVAZZA

LAVAZZA Jolie plus quick start guide

Kalorik USK CM 5 operating instructions

Kalorik

Kalorik USK CM 5 operating instructions

MAGIMIX EXPRESSO AUTRE instructions

MAGIMIX

MAGIMIX EXPRESSO AUTRE instructions

Bunn Tiger Cool Froth Series Specification sheet

Bunn

Bunn Tiger Cool Froth Series Specification sheet

Coffee Queen MOCCA BTB Service manual

Coffee Queen

Coffee Queen MOCCA BTB Service manual

K-FEE Machine operating manual

K-FEE

K-FEE Machine operating manual

Bosch VeroCafe Latte TES503 Series operating instructions

Bosch

Bosch VeroCafe Latte TES503 Series operating instructions

Gaggia Milano Magenta Plus RI8699 operating instructions

Gaggia Milano

Gaggia Milano Magenta Plus RI8699 operating instructions

Cuisinart SS-10 Instruction booklet

Cuisinart

Cuisinart SS-10 Instruction booklet

Carimali PRATICA1 GR. Installation and use manual

Carimali

Carimali PRATICA1 GR. Installation and use manual

Electrolux CREMAPRESSO EEA255 Instruction book

Electrolux

Electrolux CREMAPRESSO EEA255 Instruction book

Sage Dual Boiler SES920 Instruction book

Sage

Sage Dual Boiler SES920 Instruction book

Cafe C7CEBBS3RD3 owner's manual

Cafe

Cafe C7CEBBS3RD3 owner's manual

de Jong Duke Siro Touch 1600 user manual

de Jong Duke

de Jong Duke Siro Touch 1600 user manual

Bosch BCM8450UC/03 use and care manual

Bosch

Bosch BCM8450UC/03 use and care manual

Krups ESPRESSERIA AUTOMATIC user guide

Krups

Krups ESPRESSERIA AUTOMATIC user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.