CLEARANCES
a. The Wood Stone Phoenix oven should have a minimum 1-inch (2.54 cm) clearance to combustibles from all sides,
6-inch (15.2 cm) clearance to combustibles from the top, and 6-inch clearance (15.2 cm) from the flue collar.
If building a facade that will contact the oven, use completely non-combustible materials. Any facade wall built above or
6-inches (15.2 cm) to either side of the doorway must be of non-combustible construction. Please note that standard drywall
(or sheet rock) is considered a limited combustible. Any walls perpendicular to the front of the oven in the area 30 inches
(76.2 cm) to either side of the doorway and 36 inches (91.4 cm) in front of the oven should have a non-combustible surface.
b. The oven should be installed on a non-combustible floor surface. The non-combustible floor surface must extend 36
inches (91.4 cm) in front of and 30 inches (91.4 cm) to either side of the oven doorway.
IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS OVEN
BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
!
WARNING: Installation and servicing of this product could expose you to glasswool/ceramic
fibers as well as Calcium Silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION
WHEN INSTALLING OR SERVICING THIS APPLIANCE. Please read this entire manual before you
install the oven. Failure to follow instructions may result in property damage, bodily injury
or even death. Contact your local building or fire officials about restrictions and installation
inspection in your area.
6-inches
(15.2 cm)
Hatched area must be left
accessible and unobstructed
after installation for air
intake and routine service
of the oven burner.
6-inches
(15.2 cm)
1-inch (2.54 cm)
minimum side
clearance to
combustible
construction
Maintain 6-inch
(15.2 cm) clearance
from the exhaust
transition.
7
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free (800) 988-8103
Tel (360) 650-1111
Fax (360) 650-1166
Info@www.woodstone-corp.com or visit www.woodstone-corp.com
Phoenix Installation and Operation Manual
INSTALLATION CLEARANCES
An ongoing program of product improvement may require us to change
specifications without notice.WS-PX-3030, WS-PX-4343, WS-PX-4355
Revised September 2009