COOPERATION AND OPERATING RANGE
* 1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any
natural or articial obstacles. If there are some obstacles between a transmitter
and a receiver, it is advisable to decrease the range according to: wood and plas-
ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium
and high electrical power lines, radio and television transmitters, GSM transmit-
ters set close to a device system have also a negative inuence on the range.
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m
lack* lack*
200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m
lack* lack*
200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RADIO TRANSMITTERS DELETION
Press PROG push-button of ROP-02 device for a longer time. After 5 seconds LED
red diode switches on (signal pulsates) and then it switches off. Release the push-
button in ROP-02 - MEMORY IS DELETED.
TIME PROGRAMMING
Press PROG push-button of ROP-02 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about 5 sec-
onds) till LED red diode switches on (rst signal pulsates, next the signal is constant).
Wait again (for about 5 seconds) till LED red diode switches on (rst signal pulsates,
next the signal is constant).
for CHANNEL 1: Press PROG push-button of ROP-02 device and then release it.
LED red diode switches off and then switches on (signal pulsates). Every LED diode
pulse equals 1 second. After the adjusted time is nished (the number of LED red
diode ashes) press PROG push-button and then release it - TIME IS ADDED.
for CHANNEL 2: Wait again (for about 5 seconds) till LED red diode switches
on (rst signal pulsates, next the signal is constant). Press PROG push-button of
ROP-02 device and then release it. LED red diode switches off and then switches on
(signal pulsates). Every LED diode pulse equals 1 second. After the adjusted time
is nished (the number of LED red diode ashes) press PROG push-button and then
release it - TIME IS ADDED.
Maximum time is 18 hours for every channel.
2-CHANNEL WIRELESS CONTROL SET
RZB-04
TECHNICAL DATA
RNK-04 ROP-02
Input (supply) terminals:
-L, N
Input rated voltage:
3 V DC (battery CR2032) 230 V AC
Battery life:
3 ÷ 5 years -
Input voltage tolerance: -
-15 ÷ +10 %
Nominal frequency: -
50 / 60 Hz
Nominal power consumption:
-
0,39 W „stand-by” mode/
0,69 W operation mode 1 channel/
1,09 W operation mode 2 channels
Number of operation modes:
- 5
Number of channels:
4 2
Transmission:
radio 868,32 MHz
Transmission way: unidirectional
Coding: addressing transmission
Maximum number of transmitters:
- 32
Range: up to 250 m in the open air
Time adjustment:
-
1 s ÷ 18 hours (every second)
Optical signalling: LED red diode
Input terminals:
-IN1, IN2
Transmitter’s input (supply) terminals:
-
OUT1, OUT2 - voltage output
Relay contacts parameters:
-
2NO 5A / 250V~ AC1 1250 VA
Number of terminal clamps:
- 6
Section of connecting cables:
-up to 2,5 mm2
Ambient temperature range:
-10 ÷ +55 oC
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive
tape installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III II
Overvoltage category:
- II
Pollution degree:
- 2
Surge voltage:
- 1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm
Weig
ht: 0,038 kg 0,039 kg
Reference standard: PN-ETSI EN 300 220-1,
PN-ETSI EN 300 220-2
PN-EN 60669, PN-EN 60950,
PN-EN 61000
FUNCTIONING, MOUNTING RNK-04
By pressing the button, the transmitter sends a signal with 868,32 MHz frequency
which controls EXTA FREE receivers. Device programming procedure (adding a
transmitter to a receiver’s memory) is described in particular EXTA FREE man-
ual instructions. The device range (up to 250 m depending on a receiver) can be
increased by means of a retransmitter or few RTN-01 retransmitters. The device can
be mounted in any place by means of double-sided adhesive tape or wall plugs 5 x (3 x
30) mm. Mounting by means of wall plugs:
Remove push-buttons - to do it press a push-button on one side, and on the other
side put a screwdriver into a slot and lift it up.
Find a place on the wall to mount the transmitter, make two holes corresponding
mounting holes from the transmitter’s base.
Set wall plugs in the holes.
Fix the base by tightening the screws into wall plugs.
Place the push-buttons back.
BATTERY CHANGE
Battery discharge status is signalled by several LED red diode ashes during
transmission time.
Remove push-buttons (Fig. 1).
By means of a screwdriver lever up the printedcircuit board releasing the bottom
latch (Fig. 2) and remove it from the base.
Remove the battery from the latch. (Fig. 3)
Mount a new battery. Watch battery polarisation marked on the latch. Wrong
battery mounting may cause device damage.
Put the removed printed-circuit board back in the base.
Place the push-buttons back.
CAUTION: While changing the battery, it is suggested to press any of the but-
tons for about 5 seconds before putting it into a latch. Next press transmission
button several times to check its operation. If the transmitter does not work
properly repeat the battery change procedure.
FUNCTIONING, MOUNTING ROP-02
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-discon-
nector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special measure
equipment.
Connect the cables with the terminals in accordance with the installing diagram.
Install ROP-02 device in installation cable box.
Switch on the power supply from the mains.
The device can operate in ve modes:
MONOSTABLE the relay operates only while pressing transmitter’s push-button.
BISTABLE (one push-button) the device changes relay status cyclically always after
pressing the same pushbutton.
SWITCH ON the device switches on after pressing the pushbutton.
SWITCH OFF the device switches off after pressing the pushbutton.
TIME the device switches off according to the adjusted time (tp), but it may be
switched off before adjusted time nishes. Default settings - 15 seconds.
CAUTION! Adjusted time cannot be deleted.
MONOSTABLE mode:
Press transmitter’s push-button for a longer time. Press PROG push-button of
ROP-02 device for a longer time until LED red diode switches on (constant signal).
Next release PROG push-button. Release transmitter’s push-button. LED red diode
switches on (rst signal pulsates, next the signal is constant). Press the same trans-
mitter’s push-button and release it. LED red diode switches on (the signal pulsates)
and next the signal switches off - THE TRANSMITTER IS ADDED.
BISTABLE mode:
Press PROG push-button of ROP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Press the trans-
mitter’s push-button for a longer time. LED red diode switches on (rst signal pul-
sates, next the signal is constant). Release transmitter’s push-button. LED red diode
switches on (the signal pulsates), next the LED red diode switches off - it means the
TRANSMITTER IS ADDED.
SWITCH ON/SWITCH OFF mode (two push-buttons):
Press PROG push-button of ROP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Press and release
transmitter’s pushbutton. LED red diode switches on (rst signal pulsates, next the
signal is constant). Press and release the second transmitter’s push-button. LED red
diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER
IS ADDED.
TIME MODE (one push-button):
Press PROG push-button of ROP-02 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Press and release
transmitter’s pushbutton. LED red diode switches on (the signal pulsates, next the
signal is constant). Press and release the same transmitter’s push-button. LED red
diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER
IS ADDED.
An exemplary programming procedure with the use of P-257/2 remote controller.
The procedure for the rest of radio EXTA FREE transmitters is analogous.
CAUTION: Every transmitter can cooperate with ROP-02 in a different mode,
depending on how they were added to the device. One transmitter can be added
during one programming cycle. Full memory is signalled with pulsating LED red
diode.
RADIO TRANSMITTERS POGRAMMING - CHANNEL 1
RADIO TRANSMITTERS POGRAMMING - CHANNEL 2
Press PROG push-button of ROP-02 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about 5 sec-
onds) till LED red diode switches on (rst signal pulsates, next the signal is constant).
Choose one out of ve ROP-02 operating modes and programme the device in the
same way as for channel 1. CAUTION: For the monostable mode, press the button
on the remote before pressing PROG push-button.

This manual suits for next models

2

Other Zamel Controllers manuals

Zamel supla SRW-01 User manual

Zamel

Zamel supla SRW-01 User manual

Zamel ledix SLR-11 User manual

Zamel

Zamel ledix SLR-11 User manual

Zamel RZB-05 User manual

Zamel

Zamel RZB-05 User manual

Zamel RTM - 01 User manual

Zamel

Zamel RTM - 01 User manual

Zamel exta MOM-02 User manual

Zamel

Zamel exta MOM-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel RTD-01 User manual

Zamel

Zamel RTD-01 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel GRM-10 User manual

Zamel

Zamel GRM-10 User manual

Zamel exta life SRM-22 User manual

Zamel

Zamel exta life SRM-22 User manual

Zamel Wi-Fi supla SLW-01 User manual

Zamel

Zamel Wi-Fi supla SLW-01 User manual

Zamel SRP-02 User manual

Zamel

Zamel SRP-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel Wi-Fi supla ROW-02 User manual

Zamel

Zamel Wi-Fi supla ROW-02 User manual

Zamel RTP-01 User manual

Zamel

Zamel RTP-01 User manual

Zamel NC60 User manual

Zamel

Zamel NC60 User manual

Zamel exta SRP-05 User manual

Zamel

Zamel exta SRP-05 User manual

Zamel exita ZIM-12/08 User manual

Zamel

Zamel exita ZIM-12/08 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel SRP-03 User manual

Zamel

Zamel SRP-03 User manual

Zamel Cet Ledix SLR-01 User manual

Zamel

Zamel Cet Ledix SLR-01 User manual

Zamel exta SRM-11 User manual

Zamel

Zamel exta SRM-11 User manual

Zamel RTD-02 User manual

Zamel

Zamel RTD-02 User manual

Zamel Exta RTM-02 User manual

Zamel

Zamel Exta RTM-02 User manual

Popular Controllers manuals by other brands

ARRI SRH-3 installation guide

ARRI

ARRI SRH-3 installation guide

Alicat Scientific BC Series operating manual

Alicat Scientific

Alicat Scientific BC Series operating manual

AirCom R410 Series operating manual

AirCom

AirCom R410 Series operating manual

DIG Irrigation-Mart 710 Series instruction manual

DIG

DIG Irrigation-Mart 710 Series instruction manual

Norac UC5 Topcon X30 installation manual

Norac

Norac UC5 Topcon X30 installation manual

Dualsky Summit X Series instruction manual

Dualsky

Dualsky Summit X Series instruction manual

New Rock Technologies SX1000 installation guide

New Rock Technologies

New Rock Technologies SX1000 installation guide

Basler BE2000E instruction manual

Basler

Basler BE2000E instruction manual

Bosch Twist quick start guide

Bosch

Bosch Twist quick start guide

AirPatrol Lite combi control quick start guide

AirPatrol Lite

AirPatrol Lite combi control quick start guide

Train-Tech SV1 instruction manual

Train-Tech

Train-Tech SV1 instruction manual

SME AC-X1 user manual

SME

SME AC-X1 user manual

Beck IPC SC123 Hardware manual

Beck

Beck IPC SC123 Hardware manual

Tecnologic THP 24 operating instructions

Tecnologic

Tecnologic THP 24 operating instructions

Busch-Jaeger 1098 U-102 product manual

Busch-Jaeger

Busch-Jaeger 1098 U-102 product manual

Sensus 143-80 Series Installation and maintenance instructions

Sensus

Sensus 143-80 Series Installation and maintenance instructions

nextys OR20 instruction manual

nextys

nextys OR20 instruction manual

Bticino F20T60A manual

Bticino

Bticino F20T60A manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.