Zamel exta free RZB-01 User manual

RZB-01 WIRELESS CONTROL KIT - LIGHTING
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
VER. 003_20.05.2011
APPEARANCE
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in a
particular country. The device
should be connected accord-
ing to the details included in
this operating manual. Installation, connection
and control should be carried out by a qualied
electrician staff, who act in accordance with the
service manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Be-
fore installation make sure the connection ca-
bles are not under voltage. The cruciform head
screwdriver 3,5 mm should be used to instal the
device. Improper transport, storage, and use of
the device inuence its wrong functioning. It
is not advisable to instal the device in the fol-
lowing cases: if any device part is missing or
the device is damaged or deformed. In case of
improper functioning of the device contact the
producer.
CAUTION!
FEATURES
TECHNICAL DATADESCRIPTION
● complete set of wireless control
(2–channel button radio transmitter
RNK-02 and 1-channel bistable radio
receiver ROP-01),
● light operation control and other re-
ceivers control,
● receivers are easily installed in an
electric-light tting or in Ø60 mm junc-
tion box,
● ve operation modes: switching on
mode, switching off, monostable, bi-
stable, time (switch off delay),
● wide range of operation (up to 180 m),
● operation is optically signalled,
● low current consumption, possibility of
constant work,
● possibility of widening operation range
by means of RTN-01 retransmitter.
RZB-01 set includes radio receiver
ROP-01 used in ush and surface mo-
unting and RNK-02 transmitter, battery
powered, can be mounted in any place.
The set gives comfortable solution used
to control lighting and other receivers re-
motely.
RNK-02 ROP-01
Input (supply) terminals: - L, N
Input rated voltage: 3 V (CR2032 battery) 230 V AC
Battery life: 3 ÷ 5 years -
Input voltage tolerance: - -15 ÷ +10 %
Nominal frequency: - 50 / 60 Hz
Nominal power consumption: - 0,29 W
Number of operation modes: - 5
Number of channels: 2 1
Transmission: radio 868,32 MHz
Coding way: unidirectional
Coding: addressing transmission
Maximum number of transmitters: - 32
Range: up to 250 m in the open area up to 230 m in the open area
Time adjustment: - 1 s ÷ 18 hours (every 1 sec.)
Optic signalling of transmitter’s operation: LED red diode
Relay output clamps: - 12, 11, 14
Relay contacts parameters: - 1NO/NC 5A / 250V~ AC1 1250 VA
Number of terminal clamps: - 5
Section of connecting cables: - do 2,5 mm2
Ambient temperature range: -10 ÷ +55 oC
Operating position: free
Casing mounting:
wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree: IP20 (EN 60529)
Protection level: III II
Overvoltage category: - II
Pollution degree: 2
Surge voltage: - 1 kV (EN 61000-4-5)
Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm
Weight: 0,038 kg 0,043 kg
Reference standard:
ETSI EN 300 220-1
ETSI EN 300 220-2
EN 60669, EN 60950
EN 61000
The symbol means selective collecting
of electrical and electronic equipment.
It is forbidden to put the used
equipment together with other waste.
Optic signalling of receiver’s operation
Programming buttons
Relay output terminals
(12, 11, 14)
Input (supply) terminals (L, N)
Optic signalling of transmitter’s operation
Push-button
WARRANTY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale
CONNECTION
APPLICATION
1-channel radio ush receiver ROP-01
operates as a receiver of 8-channel
remote controller P-256/8 and of
2-channel button radio transmitter
RNK-02 (light sources switch on/switch
off control). The above mentioned
transmitters can also control operation
of radio lighting switch RWL-01
and remote control socket RWG-01.
CAPACITY
750W
250W
500W
375W
MOUNTING
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install ROP-01 device in installation cable
box.
5. Switch on the power supply from the mains.
RNK-02 FUNCTIONING, MOUNTING
By pressing the button, the transmitter sends
a signal with 868,32 MHz frequency which con-
trols EXTA FREE receivers. Device program-
ming procedure (adding a transmitter to
a receiver’s memory) is described in par-
ticular EXTA FREE manual instructions.
The device range (up to 250 m depending on
a receiver) can be increased by means of a re-
transmitter or few RTN-01 retransmitters. The
device can be mounted in any place by means
of double-sided adhesive tape or wall plugs
5 x (3 x 30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the but-
ton on one side, and on the other side put
a screwdriver into a slot and lift up the button.
2. Find a place on the wall to mount the transmit-
ter, make two holes corresponding mounting
holes from the transmitter’s base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws
into wall plugs.
5. Place the button again.
BATTERY CHANGE
Battery discharge status is signalled by sev-
eral LED red diode ashes during transmis-
sion time.
1. Remove the button (as in point 1 of mounting).
2. By means of a screwdriver lever up the
printed-circuit board releasing the bottom latch
(Fig. 2), and remove it from the base.
3. Remove the battery from the latch.
4. Mount a new battery. Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back in
the base.
6. Put back the button.
CAUTION: While changing the battery,
it is suggested to press any of the buttons
for about 5 seconds before putting it into
a latch. Next press transmission button sev-
eral times to check its operation. If the trans-
mitter does not work properly repeat the bat-
tery change procedure.
The ZAMEL company
devices which are
characterised with this sign
can cooperate
with each other.

VER. 003_20.05.2011
RADIO TRANSMITTERS PROGRAMMING
TIME PROGRAMMING
RADIO TRANSMITTERS DELETION
COOPERATION AND OPERATING RANGE
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
* - 1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any natural or articial obstacles. If there are some obstacles be-
tween a transmitter and a receiver, it is advisable to decrease the range according to:
wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %,
Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device sys-
tem have also a negative inuence on the range.
ROP-01 OPERATION
ROP-01 can operate in ve modes:
MONOSTABLE
the relay operates only
while pressing transmit-
ter’s push-button.
BISTABLE
(one push-button) the
device changes relay
status cyclically always
after pressing the same push-
-button.
SWITCH ON
the device switches on
after pressing the push-
-button.
SWITCH OFF
the device switches off
after pressing the push-
-button.
TIME
the device switches
off according to the
adjusted time (tp),
but it may be switched off before
adjusted time nishes. Default
settings - 15 seconds.
CAUTION! Adjusted time can-
not be deleted.
TRANSMITTERS RECEIVERS
RNK-02
2–channel button
radio transmitter
RNL-01
Radio
foot transmitter
ROP-01
1-channel
radio receiver
RWL-01
Radio lighting
switch
RNK-04
4-channel button
radio transmitter
RTI-01
IR/EXTA FREE
transceiver
ROP-02
2-channel
radio receiver
RWG-01
Remote control
socket
P-256/8
8-channel
remote controller
RNM-10
4-channel radio
modular transmitter
RDP-01
1-channel
radio dimmer
SRP-02
Radio roller blinds
controller
P-257/4
4-channel
remote controller
RNP-01
4-channel
radio transmitter
ROB-01/12-24V
Radio
gate controller
SRP-03
Central radio roller
blinds controller
P-257/2
2-channel
remote controller
RNP-02
4-channel
radio transmitter
ROM-01
1-channel radio
modular receiver
ROM-10
2-channel
radio modular receiver
RCR-01
Radio
motion sensor
RXM-01
Translator
RS-485/EXTA FREE
ACCESSORIES
ANT-01
External antenna
RTN-01
Retransmitter
Maximum time is 18 hours.
MONOSTABLE mode:
BISTABLE mode:
SWITCH ON/SWITCH OFF mode (two push-buttons):
TIME mode (one push-button):
An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters
is analogous. CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to
the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode.
Press transmitter’s
push-button for a
longer time.
Press the transmitter’s push-button
for a longer time. LED red diode switches
on (rst signal pulsates,
next the signal is constant).
Press PROG push-button of ROP-01
device and then release it. LED red diode
switches on (rst signal pulsates,
next the signal is constant).
Press the transmitter’s push-button
for a longer time. LED red diode switches
on (rst signal pulsates,
next the signal is constant).
Release transmitter’s
push-button. LED red diode
switches on
(rst signal pulsates, next
the signal is constant).
Release transmitter’s push-button. LED red
diode switches on (the signal pulsates), next
the LED red diode switches off - it means
the TRANSMITTER IS ADDED.
Press and release the same transmitter’s
push-button. LED red diode switches on
(signal pulsates) and then switches off -
THE TRANSMITTER IS ADDED.
Release transmitter’s push-button. LED
red diode switches on (the signal pulsates),
next the LED red diode switches off - it
means the TRANSMITTER IS ADDED.
Press the same transmitter’s push-
-button and release it. LED red dio-
de switches on (the signal pulsates)
and next it switches off -
THE TRANSMITTER IS ADDED.
Press PROG push-button of ROP-01 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of ROP-01 device
for a longer time until LED red diode
switches on (constant signal).
Next release PROG push-button.
Press PROG push-button of ROP-01
device for a longer time until LED red
diode switches on (constant signal).
Next release PROG push-button.
Press PROG push-button of ROP-01
device for a longer time till LED red
diode switches on (constant signal).
Next release PROG push-button.
Press PROG push-button of ROP-01 device for a longer time till
LED red diode switches on (constant signal). Next release PROG
push-button. Wait (for about 5 seconds) till LED red diode switches
on (rst signal pulsates, next the signal is constant).
After the adjusted time is
nished (the number of LED
red diode ashes) press
PROG push-button and then
release it - TIME IS ADDED.
Press PROG push-button of ROP-01 device
and then release it. LED red diode switches
off and then switches on (signal pulsates).
Every LED diode pulse equals 1 second.
Press PROG push-button of ROP-01
device for a longer time.
After 5 seconds LED red diode switches on
(signal pulsates) and then it switches off.
Release the push-button in ROP-01 -
MEMORY IS DELETED.
1s 2s ns

X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Power Management IC Development Tools category:
Click to view products by Zamel manufacturer:
Other Similar products are found below :
EVAL6482H-DISC EVAL-AD5522EBUZ EVAL-ADM1060EBZ EVAL-ADM1073MEBZ EVAL-ADM1166TQEBZ EVAL-
ADM1168LQEBZ EVAL-ADM1171EBZ EVAL-ADM1276EBZ EVB-EN5319QI EVB-EN5365QI EVB-EN6347QI EVB-EP5348UI
MIC23158YML EV MIC23451-AAAYFL EV MIC5281YMME EV 124352-HMC860LP3E ADM00513 ADM8611-EVALZ ADM8612-
EVALZ ADM8613-EVALZ ADM8615-EVALZ ADP1046ADC1-EVALZ ADP1055-EVALZ ADP122-3.3-EVALZ ADP130-0.8-EVALZ
ADP130-1.2-EVALZ ADP130-1.5-EVALZ ADP130-1.8-EVALZ ADP160UJZ-REDYKIT ADP166UJ-EVALZ ADP1712-3.3-EVALZ
ADP1714-3.3-EVALZ ADP1715-3.3-EVALZ ADP1716-2.5-EVALZ ADP1740-1.5-EVALZ ADP1752-1.5-EVALZ ADP1754-1.5-EVALZ
ADP1828LC-EVALZ ADP1870-0.3-EVALZ ADP1871-0.6-EVALZ ADP1873-0.6-EVALZ ADP1874-0.3-EVALZ ADP1876-EVALZ
ADP1879-1.0-EVALZ ADP1882-1.0-EVALZ ADP1883-0.6-EVALZ ADP197CB-EVALZ ADP199CB-EVALZ ADP2102-1.25-EVALZ
ADP2102-1.2-EVALZ
Other Zamel Controllers manuals

Zamel
Zamel Exta RTM-02 User manual

Zamel
Zamel ledix SLR-11 User manual

Zamel
Zamel RTD-01 User manual

Zamel
Zamel ledix SLR-13 User manual

Zamel
Zamel RTD-02 User manual

Zamel
Zamel exta ZIM-12/25 User manual

Zamel
Zamel RNK-02 User manual

Zamel
Zamel RZB-03 User manual

Zamel
Zamel exta SRM-11 User manual

Zamel
Zamel exta life ROB-21 User manual

Zamel
Zamel exta ZCM-22 Series User manual

Zamel
Zamel Exta Life EFC-01 User manual

Zamel
Zamel Cet Ledix SLR-01 User manual

Zamel
Zamel NC60 User manual

Zamel
Zamel ROW-01 User manual

Zamel
Zamel exta MOM-02 User manual

Zamel
Zamel RZB-05 User manual

Zamel
Zamel supla SRW-01 User manual

Zamel
Zamel RTS-01A User manual

Zamel
Zamel exita ZIM-12/08 User manual