IES5028 Series Managed
Industrial Ethernet Switch
Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Song Bai Road, Nanshan
District, Shenzhen, 518108, China
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check the integrity of package and accessories while
first using the switch.
1.
Industrial Ethernet switch X 1
2.
Terminal block
3.
Power line (AC products)
4.
Mounting lug
5.
Quick installation guide
6.
Foot pad
7.
Certification
8.
Warranty card
9.
CD
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series of products are 28-port 100M/Gigabit layer 2
rack-mounted managed industrial Ethernet switches. Models
include:
Model I. IES5028-4GS (4 Gigabit SFP + 24 100M copper
ports)
Model II. IES5028-4GS-2F (4 Gigabit SFP + 22 100M
copper ports + 2 100M fiber ports)
Model III. IES5028-4GS-4F (4 Gigabit SFP + 20 100M
copper ports + 4 100M fiber ports)
Model IV. IES5028-4GS-8F (4 Gigabit SFP + 16 100M
copper ports + 8 100M fiber ports)
Model V. IES5028-4GS-12F (4 Gigabit SFP + 12 100M
copper ports + 12 100M fiber ports)
Model VI. IES5028-4GS-16F (4 Gigabit SFP + 8 100M
copper ports +16 100M fiber ports)
Model VII. IES5028-4GS-20F (4 Gigabit SFP + 4 100M
copper ports + 20 100M fiber ports)
Model VIII. IES5028-4GS-24F (4 Gigabit SFP + 24 100M fiber
ports)
【Panel Design】
Front view
Rear view
Top view
Left view
Right view
1. Restore factory defaults button
2. Console port
3. Ethernet port connection indicator
4. Device running status indicator RUN
5. Power supply input status indicator PWR
6. Relay alarm status indicator ALM
7. Rack mounting lug
8. Power input terminal block
9. Relay output terminal block
10. Gigabit SFP slot
11. Ethernet port connection indicator
12. 100M copper port
13. 100M fiber port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in moist area or near
water, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running,
please don't directly contact to avoid scalding.
【Installation of Rack-mounted Device】
Step 1 Select the device installation location to reserve
sufficient size.
Step 2 Adopt screws to install the mounting lugs in the
device position as figure below.
Step 3 Place the device in the rack, adopt 4 screws to
install the mounting lugs on the left and right side in
the rack.
Step 4 Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Rack-mounting Device Disassembling】
Step 1 Power off the device.
Step 2 Unscrew the fixing screw of mounting lug on the
rack.
Step 3 Remove the device from the rack, disassembling
ends.
【Power Supply Connection】
This series of devices provide 5 pins 5.08mm pitch terminal
blocks, power supply occupies 3 pins on the left.The power
supply has nonpolarity and anti-reverse function, the device
can be normally working after reverse connection. The pin
definition of power supply as follows:
Pin NO.
1
2
3
Definition
L/+
GND
N/-
Single power supply
This series of products supports single
power supply scheme, power supply
value range is: 100~240VAC/DC.
Dual power supply
This series of products support dual
power supply scheme and provide P1
and P2 independent power supply
systems. When one of the power supply
system fails, the device can operate
uninterruptedly and normally, which has
improved the reliability of network operation. Power supply
value range is: 100~240VAC/DC.
Notes:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First unpin the power plug, and
then remove the wiring part of terminal block, please
pay attention to the operation order above.
【Relay Connection】
This series of devices provide 5 pins 5.08mm pitch terminal
blocks; power supply occupies 3 pins on the left. Relay
terminals are a pair of normally closed contacts in device
alarm relay. They are open circuit in normal non alarm state,
closed when power off. This series of single and dual power
supply products respectively support 1 or 2 channels relay
alarm output and disconnection alarm of power supply or port.
The device can be connected to alarm indicator, alarm buzzer,
or other switching value collecting device, it can timely inform
operator when alarm occurs. The pin definition of relay as
follows:
Pin NO.
4
5
Definition
R+
R-
【Console Port Connection】
The device provides 1 program debugging port based on
RS-232 serial port; it can manage the device CLI commands
after being connected to PC. The interface adopts RJ45 port.
Definition of RJ45 pins as follows:
【Restore Factory Defaults】
Steps of restore factory defaults as follows: Press the button
of restore factory defaults, power on the device again; after
3~4s, loosen the button to restore factory defaults.
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive and simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Status
Description
PWR
ON
Power supply is connected and
running normally
OFF
Power supply is disconnected or
running abnormally.
ALM
ON
Power supply, port link alarm
OFF
Power supply, port link without alarm
RUN
ON
The device is powering on or
abnormal
OFF
The device isn't powered on or is
abnormal
Blinking
Flash 1 time per second, the device
is running normally.
Link/Act
(1-24,
ON
Ethernet port connection is active.
Blinking
Ethernet port is in network active
G1-G4)
status
OFF
Ethernet port connection is inactive
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Step 4 Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Step 5 Enter device’s IP address in the address bar of the
computer browser.
Step 6 Enter device’s username and password in the login
window as shown below.
Step 7 Click “OK”button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device is
“admin”.
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit SFP
1000Base-SFP, SFP slot, LC
interface
100M copper port
10/100Base-T(X) self-adapting
RJ45 port, half/full duplex
self-adaption, support
MDI/MDI-X self-adaption
100M fiber port
100Base-FX, optional
SC/ST/FC interface
Console port
CLI command management port
(RS-232), RJ45
Alarm interface
5 pins 5.08mm pitch terminal
blocks, including 2 alarm
terminal blocks.Support 1 relay
alarm output, current load
capacity is 5A@30VDC or
10A@125VAC
Indicator
Power supply indicator, run
indicator, interface indicator,
alarm indicator
Exchange Attributes
Backplane bandwidth
12.8G
Packet buffer size
3Mbit
MAC table size
8K
Power supply
Input power supply
100~240VAC/DC, support
single or dual power supply
scheme, and 8A output
overcurrent protection
Pin Number
2
3
5
Pin Definition
TXD
RXD
GND
Access terminal
5 pins 5.08mm pitch terminal
blocks, including 3 pins power
supply terminal blocks
Consumption
IES5028-4GS
No-load: 7.4W@220VAC
Full-load: 13.1W@220VAC
IES5028-4GS-2F
No-load: 8.7W@220VAC
Full-load: 14.4W@220VAC
IES5028-4GS-4F
No-load: 10W@220VAC
Full-load: 15.7W@220VAC
IES5028-4GS-8F
No-load: 12.6W@220VAC
Full-load: 18.3W@220VAC
IES5028-4GS-12F
No-load: 15.2W@220VAC
Full-load: 20.9W@220VAC
IES5028-4GS-16F
No-load: 17.8W@220VAC
Full-load: 23.5W@220VAC
IES5028-4GS-20F
No-load: 19.4W@220VAC
Full-load: 24.1W@220VAC
IES5028-4GS-24F
No-load: 22W@220VAC
Full-load: 26.2W@220VAC
Environmental Limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade
IP30 (metal shell)

This manual suits for next models

8

Other 3One data Switch manuals

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES2010 Series User manual

3One data

3One data IES2010 Series User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data IES7120G Series User manual

3One data

3One data IES7120G Series User manual

3One data IES6320 Series User manual

3One data

3One data IES6320 Series User manual

3One data ES5026 User manual

3One data

3One data ES5026 User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data ES2010G-2GS User manual

3One data

3One data ES2010G-2GS User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data IES2008 User manual

3One data

3One data IES2008 User manual

3One data TNS5800-8GP16GT-P24VDC User manual

3One data

3One data TNS5800-8GP16GT-P24VDC User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES3016 Series User manual

3One data

3One data IES3016 Series User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

3One data ES5018 User manual

3One data

3One data ES5018 User manual

3One data IES2005 User manual

3One data

3One data IES2005 User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES2305 Series User manual

3One data

3One data IES2305 Series User manual

3One data IES7116G-8GS Series User manual

3One data

3One data IES7116G-8GS Series User manual

3One data IES6116 Series User manual

3One data

3One data IES6116 Series User manual

3One data IES2210 Series User manual

3One data

3One data IES2210 Series User manual

3One data IES6100PN-8T-2LV User manual

3One data

3One data IES6100PN-8T-2LV User manual

Popular Switch manuals by other brands

Grizzly G4668 parts list

Grizzly

Grizzly G4668 parts list

Hama Uni Quattro LNB operating instructions

Hama

Hama Uni Quattro LNB operating instructions

Pilz PSEN ma1.3n-20 operating instructions

Pilz

Pilz PSEN ma1.3n-20 operating instructions

UGREEN CM475 user manual

UGREEN

UGREEN CM475 user manual

Omron A2W-R**-WC1 Series user manual

Omron

Omron A2W-R**-WC1 Series user manual

Allied Telesis AT-x510DP-52GTX installation guide

Allied Telesis

Allied Telesis AT-x510DP-52GTX installation guide

Extron electronics VSW 2VGA A Setup guide

Extron electronics

Extron electronics VSW 2VGA A Setup guide

Cisco 2960-48TC - Catalyst Switch datasheet

Cisco

Cisco 2960-48TC - Catalyst Switch datasheet

UTEPO UTP3318S-PSB250-M0 user manual

UTEPO

UTEPO UTP3318S-PSB250-M0 user manual

Luminex GigaCore 16RFO quick start guide

Luminex

Luminex GigaCore 16RFO quick start guide

Dell X1000 Series Getting started guide

Dell

Dell X1000 Series Getting started guide

IPGARD SDPN-2S-P manual

IPGARD

IPGARD SDPN-2S-P manual

Roland V-8HD Startup guide

Roland

Roland V-8HD Startup guide

EcoFlow DELTA Pro manual

EcoFlow

EcoFlow DELTA Pro manual

Avocent DSR Series DSR2035 release note

Avocent

Avocent DSR Series DSR2035 release note

Manhattan 160612 user manual

Manhattan

Manhattan 160612 user manual

MLis MLB-E42XX-28-A Quick installation guide

MLis

MLis MLB-E42XX-28-A Quick installation guide

Endress+Hauser Liquiphant FTL64 operating instructions

Endress+Hauser

Endress+Hauser Liquiphant FTL64 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.