IES3016 series
Industrial Ethernet switches
User manual
Shenzhen 3onedata Technology Co., Ltd.
Tel: +86-755-26702668 Fax: +86-755-26703485
www.3onedata.com
【Summarize】
IES3016 series is a Plug-and-play unmanaged industrial Ethernet
switch. The IES3016 industrial Ethernet switches consists of 16
Ethernet ports. The IES3016-2F consists of 14 Ethernet ports and
2 Fiber ports. The IES3016-4F consists of 12 Ethernet ports and 4
Fiber ports. The IES3016-6F consists of 10 Ethernet ports and 6
Fiber ports. The IES3016-8F consists of 8 Ethernet ports and 8
Fiber ports that provide an economical solution for your industrial
Ethernet connection. It supports auto flow control, full/half duplex
mode and MDI/MDI-X self-adaption. Product accorded to CE,
FCC standard and Industry grade 4 design requirement, support 2
redundant power input and -40~75℃working temperature, can
meet all kinds of Industrial environment requirement. It can use in
power, water conservancy, transportation area etc. The switch
support AC power input series and DC power input series
optional.
【Packing list】
Please check the packaging and accessories by your first using.
Industrial Ethernet switch ⅹ1
User manual ⅹ1
Certificate of quality ⅹ1
Warranty card ⅹ1
Please inform us or our distributor if your equipments have been
damaged or lost any accessories, we will try our best to satisfy
you.
【Feature】
High performance network exchange technology
Support IEEE802.3, IEEE802.3u, IEEE 802.3x
Support MAC address auto-learning, auto-aging
Support flow control
Support 8K MAC address
Support 12.8Gbps backboard bandwidth
DC power input series support redundancy power
supply(12~48VDC)
AC power input series supportAC power supply(100~
240VAC/DC)
Reliable Industrial grade design
Industrial grade 4 design, -40-75℃work temperature
No fan deign
IP40 protection grade
DIN rail
【Panel layout】
Rear view Vertical view and bottom view
Front panel view
IES3016 IES3016-2F
IES3016-4F IES3016-6F
IES3016-8F
1. DIP switches (Retain)
2. Console port (Retain)
3. 2-pin terminal block for relay output (Retain)
4. Ground screw
5. Power input terminal block
6. DIN-Rail mounting kit
7. System running LED
8. Power indicator
9. Relay alarm LED
10. Link/ACT LEDs
11. 10Base-T /100Base-TX Ethernet port
12. 100Base-FX fiber port
【Appearance and dimension】
The series of products are the same size, and the number of the
Ethernet interface is different. Unit (mm)
【Power supply input】
DC Series Switch:
The product top panel provided 4 bit power supply input terminal
block, support DC input. DC power supply input supported
redundancy function, provided PWR1 and PWR2 power input,
can use for single, and can connect 2 separately power supply
system, use 1 pair terminal block connect the device at the same
time. If one of the power systems broke, the device can work
un-interruptible. Built-in overcorrect protection, Reverse
connection protection. Voltage input range is 12 ~48VDC
(terminal block defined as: V1-、V1+、V2-、V2+).
AC Series Switch:
The Industrial Ethernet switches have singe power and
redundancy power two kinds of power input. The singe power AC
series top panel provides 3 bit terminal block for AC100~240V
power entered (L/+, PG, N/-)
Important notice:
1. Power ON operation: first of all, insert power cable’s terminal
block into device’s power port, then insert power supply plug into
power source
2. Power OFF operation: First off all, unpin power plug, then
strike the terminal block, please take care of operation sequence.
【Communication connector】
10/100BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP.
The connect distance is no more than 100m. 100Mbps is used
120Ω of UTP 5; 10Mbps is used 120Ω of UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. Can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connections in MDI. 1→3, 2→6, 3→1, 6→2 are
used as cross wiring in the MDI-X port of Converter and HUB.
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin
in the table as below.
1 8
NO. MDI signal MDI-X signal
1 TX+ RX+
2 TX- RX-
3 RX+ TX+
6 RX- TX-
4, 5, 7, 8 — —
Note:“TX±”Transmit Data±,“RX±”Receive Data±,“—”Not Use.
MDI (straight-through cable)
MDI-X (Cross over cable)
MDI/MDI-X auto connection makes switch easy to use for
customers without considering the type of network cable.
100Base-FX Fiber port
100Base-FX full-duplex SM or MM port, SC/ST/FC type .The
fiber port must be used in pair, TX (transmit) port connect remote
switch’s RX (receive) port; RX (receive) port connect remote
switch’s TX (transmit) port.
The optical fiber connection supports the line to instruct enhance
the reliability of network effectively.
Suppose: If you make your own cable, we suggest labeling the
two sides of the same line with the same letter (A-to-A and
B-to-B, shown as below, or A1-to-A2 and B1-to-B2).
【LED Indicator】
LED indictor light on the front panel of product, the function of
each LED is described in the table as below.
System Indication LED
LED State Description
PWR
(P1, P2)
ON Power is being supplied to power
input PWR input
OFF Power is not being supplied to
power input PWR input
RUN ON/OFF System is not running well
Blinking System is running well
Link/ACT
(1~16)
ON Port connection is active
Blinking Data transmitted
OFF Port connection is not active
ALARM ON Has alarm information
OFF No alarm information
【Installation】
Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Power: DC dual power supply series products 12 ~ 48VDC
AC single power supply series products 100~240VAC/DC
5. Environment: working temperature -40~75℃
Storage Temperature: -40~85℃
Relative humidity 5%~95%
DIN Rail Installation
In order to use in industrial environments expediently, the product
adopt 35mm DIN-Rail installation, the installation steps as below:
1.Examine the DIN-Rail attachment
2.Examine DIN Rail whether be firm and the position is
suitability or not.
3.Insert the top of the DIN-Rail into the slot just below the
stiff metal spring.
4.The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type and specification of
cable match the requirement before cable laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and laying
position need to match construction requirements, and cable
length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.
【Specification】
Technology
Standard: Support IEEE802.3, IEEE802.3u, IEEE 802.3x,
Flow control: IEEE802.3x flow control, back press flow control
Exchange attribute
100M forward speed: 148810pps
Transmit mode: store and forward
System exchange bandwidth: 12.8G
MAC address table: 8K
Memory: 4M
Interface
Electric port: 10Base-T/100Base-TX auto speed control, Half/full
duplex and MDI/MDI-X auto detect
100M optic fiber port: 100Base-FX, SC/ST/FC connector, support
single mode (20/40/60/80Km optional), multi
mode (2Km), wavelength: 1310nm, 1550nm
Transfer distance:
Twisted cable: 100M (standard CAT5/CAT5e cable)
Multi-mode: 1310nm, 2Km
Single-mode: 1310nm, 20/40/60Km
1550nm, 80/100/120Km
LED indicator:
Run indicator: Run
Interface indicator: Link (1~16)
Power supply indicator: PWR (P1, P2)
Power supply
DC Series
Input voltage: 12~48VDC
Support DC dual power supply redundancy
AC Series
Input voltage: 100~240VAC/DC
Type of input: 4 bit terminal block
Consumption
IES3016-P (12~48VDC):
Unload consumption: 4.83W@24VDC
Full load consumption: 7.30W@24VDC
IES3016-2F-P (12~48VDC):
Unload consumption:6.12W@24VDC
Full load consumption: 8.33W@24VDC
IES3016-4F-P (12~48VDC):
Unload consumption: 7.6W@24VDC
Full load consumption: 9.29W@24VDC
IES3016-6F-P (12~48VDC):
Unload consumption: 8.79W@24VDC
Full load consumption: 10.49W@24VDC
IES3016-8F-P (12~48VDC):
Unload consumption: 10.18W@24VDC
Full load consumption: 10.26W@24VDC
Working environment:
Working temperature: -40~75℃
Storage temperature:-40~85℃
Relative Humidity: 5%~95% (no condensation)
Mechanical Structure:
Shell: IP40 protect grade, metal shell
Installation: DIN-Rail
Size (W×H×D): 160mm×70mm×130mm
Industry Standard:
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 4
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 4
EN61000-4-6 (CS), Level 3
EN61000-4-8, Level 5
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Certification
CE, FCC, RoHS, UL508 (Pending)
Warranty: 5 years

Other 3One data Switch manuals

3One data IPS7110-2GC-4POE Series User manual

3One data

3One data IPS7110-2GC-4POE Series User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data TNS5800D User manual

3One data

3One data TNS5800D User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES7120G Series User manual

3One data

3One data IES7120G Series User manual

3One data ICS5400 Series User manual

3One data

3One data ICS5400 Series User manual

3One data IES205 Manual

3One data

3One data IES205 Manual

3One data IES615-2DI(3IN1) Series User manual

3One data

3One data IES615-2DI(3IN1) Series User manual

3One data IES5024-P User manual

3One data

3One data IES5024-P User manual

3One data IES5024 Series User manual

3One data

3One data IES5024 Series User manual

3One data IES1024 Series User manual

3One data

3One data IES1024 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data ICS5428 Series User manual

3One data

3One data ICS5428 Series User manual

3One data IPS215-4POE User manual

3One data

3One data IPS215-4POE User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data IES5028G Series User manual

3One data

3One data IES5028G Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data IES2305 Series User manual

3One data

3One data IES2305 Series User manual

3One data ICS6420 Series User manual

3One data

3One data ICS6420 Series User manual

3One data IES6210 Series User manual

3One data

3One data IES6210 Series User manual

Popular Switch manuals by other brands

J.Burrows JBUSBHD015 instruction manual

J.Burrows

J.Burrows JBUSBHD015 instruction manual

Pepperl+Fuchs LVL-M4 instruction manual

Pepperl+Fuchs

Pepperl+Fuchs LVL-M4 instruction manual

Belden grass valley SIRIUS 800 Series Operating System Upgrade Manual

Belden

Belden grass valley SIRIUS 800 Series Operating System Upgrade Manual

Nexxt Solutions NHE-R100 manual

Nexxt Solutions

Nexxt Solutions NHE-R100 manual

PCB Piezotronics IMI SENSORS EX686B11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX686B11 Installation and operating manual

Hawking HKS112U user manual

Hawking

Hawking HKS112U user manual

ANTAIRA LMX-C602G-SFP-V2 Series Hardware manual

ANTAIRA

ANTAIRA LMX-C602G-SFP-V2 Series Hardware manual

PKP FS13 instruction manual

PKP

PKP FS13 instruction manual

HP A5120 EI Series Configuration guide

HP

HP A5120 EI Series Configuration guide

D-Link DGS-3000 series reference guide

D-Link

D-Link DGS-3000 series reference guide

Atlantis NetMaster F8P instruction manual

Atlantis

Atlantis NetMaster F8P instruction manual

Dell PowerConnect 6024 Getting started guide

Dell

Dell PowerConnect 6024 Getting started guide

Advantech EKI-2528i-m12 Startup manual

Advantech

Advantech EKI-2528i-m12 Startup manual

NETGEAR XS708T Hardware installation guide

NETGEAR

NETGEAR XS708T Hardware installation guide

Siemens SITRANS LPS200 operating instructions

Siemens

Siemens SITRANS LPS200 operating instructions

Acnodes KC801 user manual

Acnodes

Acnodes KC801 user manual

Konig KN-HDMISW02 manual

Konig

Konig KN-HDMISW02 manual

D-Link DGS-1250-28X Quick installation guide

D-Link

D-Link DGS-1250-28X Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.