manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES2008 User manual

3One data IES2008 User manual

Other 3One data Switch manuals

3One data IPS3110 Series User manual

3One data

3One data IPS3110 Series User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data IES7120-4GS Series User manual

3One data

3One data IES7120-4GS Series User manual

3One data ES1016 User manual

3One data

3One data ES1016 User manual

3One data IES6300TSN-8GT2GS-2LV User manual

3One data

3One data IES6300TSN-8GT2GS-2LV User manual

3One data IES7110 3GS Series User manual

3One data

3One data IES7110 3GS Series User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data IES2210 Series User manual

3One data

3One data IES2210 Series User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data ICS5000-E24GP4GS User manual

3One data

3One data ICS5000-E24GP4GS User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES2005-5T-P48 User manual

3One data

3One data IES2005-5T-P48 User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES215-1GX-4G User manual

3One data

3One data IES215-1GX-4G User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES2016-16T Series User manual

3One data

3One data IES2016-16T Series User manual

3One data IES618-4D Series User manual

3One data

3One data IES618-4D Series User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IPS7110 Series User manual

3One data

3One data IPS7110 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IES2008
Unmanaged Industrial Ethernet
Switch Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1.
Industrial Ethernet switch
2.
Certification
3.
Quick installation guide
4.
Warranty card
5.
DIN-Rail mounting attachment
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This product is full 100M unmanaged DIN-Rail industrial
Ethernet switch. The model is IES2008 (8 100M copper ports
+ 1 12~48VDC/24VAC power supply)
【Panel design】
Rear view, bottom view and top view
Front view and side view
1. DIN-Rail mounting kit
2. Power supply input terminal block
3. DIP switch
4. Grounding screw
5. Power supply input status indicator PWR
6. Copper port connection indicator
7. 100M Ethernet copper port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
For convenient usage in industrial environments, the product
adopts 35mm DIN-Rail mounting, mounting steps as below:
Check whether the DIN-Rail mounting kit that
Step 1
comes with the device is installed firmly.
Insert the bottom of DIN-Rail mounting kit (one side
Step 2
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed on
Step 3
DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Power off the device.
Step 1
After lift the device upward slightly, first shift out the
Step 2
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
DC power supply
This series provide 3-pin 5.08 pitch power
input terminal blocks. Power supply range:
12~48VDC/24VAC
【DIP Switch Settings】
It provides 4-pin DIP switch for function settings,
among which “ON” is enable valid end.
The definitions of DIP switch are as follows:
DIP
Definition
Operation
1
Loop detection
Set the DIP switch to ON to
enable the loop detection
function.
2
Storm suppression
Set the DIP switch to ON to
enable the storm
suppression function.
3
One-key VLAN
Set the DIP switch to ON to
enable VLAN function, port
1 can communicate with
DIP
Definition
Operation
other ports, while other ports
are isolated from each
other.
4
Flow control
Set the switch to ON to
enable the flow control
function
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
PWR
ON
Power supply is connected and
running normally
OFF
Power supply is disconnected
and running abnormally.
Link/ACT
(1-8)
ON
Ethernet port connection is
active.
Blinking
Data transmitted
OFF
Ethernet port connection is
inactive.
【Specification】
Panel
100M copper port
10/100Base-T(X) self-adapting
RJ45 port, full/half duplex
self-adaption, support
MDI/MDI-X self-adaption
Indicator
Power indicator, interface
indicator
Exchange attributes
Backplane bandwidth
1.6G
MAC table size
2K
Power supply
Input power supply
12~48VDC/24VAC
Access terminal
3 pins 5.08mm pitch terminal
blocks
Support anti-reverse connection
and over-current protection
Consumption
No-load
0.5W@24VDC
Full-load
1.4W@24VDC
Environmental Limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade
IP40 (metal shell)
MTBF
540249 hrs