manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES2305 Series User manual

3One data IES2305 Series User manual

IES2305 Series
Unmanaged Industrial Ethernet
Switch
Quick Installation Guide
3onedata Co., Ltd.
【Package Checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1. S
witch (with terminal
block)
2. DIN-
Rail mounting
attachment
3.
Certification
4.
Warranty card
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series are 5-port Gigabit unmanaged industrial Ethernet
switches. For convenience, the products of this series adopt
the following number on the left in this guide, please affirm the
number of your product.
Model I. IES2305-5GT-P48 (5 Gigabit copper ports + 1
12~48VDC power supply)
Model II. IES2305-5GT-P220 (5 Gigabit copper ports + 1
100~240VAC power supply)
Model III. IES2305-4GP1GT-P48 (4 100M PoE copper ports
+ 1 Gigabit copper port + 1 48VDC power supply)
Model IV. IES2305-4GP1GS-P48 (4 Gigabit PoE copper
ports + 1 Gigabit SFP + 1 48VDC power supply)
Model V. IES2305-4GP1GF-P48 (4 Gigabit PoE copper
ports + 1 Gigabit fiber port + 1 48VDC power
supply)
Model VI. IES2305-4GT1GS-P48 (4 Gigabit copper ports + 1
Gigabit SFP + 1 12~48VDC power supply)
Model VII. IES2305-4GT1GS-P220 (4 Gigabit copper ports +
1 Gigabit SFP + 1 100~240VAC power supply)
Model VIII. IES2305-4GT1GF-P48 (4 Gigabit copper ports + 1
Gigabit fiber port + 1 12~48VDC power supply)
Model IX. IES2305-4GT1GF-P220 (4 Gigabit copper ports +
1 Gigabit fiber port + 1 100~240VAC power
supply)
【Panel Design】
Front view
Model I, II Model III Model IV
Model V Model VI, VII Model VIII, IX
Rear view, Bottom view and Top view
1. Power supply indicator
2. Gigabit Copper Port
3. Interface connection indicator
4. PoE indicator
5. Gigabit PoE copper port
6. Gigabit SFP
7. Gigabit fiber port
8. DIN-Rail mounting kit
9. Power input terminal block
10. DIP switch
11. Grounding screw
【Mounting Dimension】
Unit: mm
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Te l :
+86 0755-26702688
Fax:
+86 0755-26703485
【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3 Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1 Power off device.
Step 2 After lifting the device upward slightly, first shift out
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notice:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Power Supply Connection】
12~48VDC power supply
Model I, VI, VIII devices of this series support
DC power input, and provide 3-pin terminals
with a spacing of 7.62 mm. The power supply
has non-polarity function. Voltage range:
12~48VDC. The pin definitions of power supply are shown as
follows:
PIN
1
2
3
Definition
V+
FG
V-
48VDC power supply
Model III, IV, V devices of this series support
DC power input, and provide 3-pin terminals
with a spacing of 7.62 mm. The power
supply has anti-reverse connection function.
Support 48V PoE, power range: 48VDC (44~55VDC). The pin
definitions of power supply are shown as follows:
PIN
1
2
3
Definition
V+
FG
V-
AC power supply
Model II, VII, IX devices of this series support
AC power input, and provide 3-pin terminals
with a spacing of 7.62 mm. Power supply
value range is: 220VAC (100~240VAC). The
pin definitions of power supply are shown as follows:
PIN
1
2
3
Definition
L
FG
N
Notice:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First, remove the power plug,
and then remove the wiring section of terminal block.
Please pay attention to the above operation sequence.
【DIP Switch Settings】
This series provide 4-pin DIP switch for function
setting, where "ON" is the enabled end. DIP
switches definition as follows:
DIP
Definition
Operation
1 Jumbo frame Set the DIP to ON to enable jumbo
frame function
2 Flow Control Set the DIP to ON to enable flow
control function
3
One-key
VLAN
Set the DIP to ON to enable VLAN
function.
Model I-Model III: copper port
1 is interconnected with other
interfaces, and other ports
except copper port 1 are
isolated from each other.
Model IV- Model IX: fiber port
(5 ports)port is interconnected
with other interfaces, and
other ports except fiber ports
are isolated from each other.
4 Port 100M Set the DIP to ON, port rate would
be forced to be in 100M
[Checking LED Indicator]
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the detailed status of each LED is described
in the table as below:
LED
Indicate
Description
PWR
ON
PWR is connected and
running normally
OFF
PWR is disconnected and
running abnormally
PoE (G1-G4)
ON
POE port is powering other
devices normally
OFF
POE is disabled or
disconnected
Link/ACT
(G1-G5)
ON
Port has established valid
network connection
Blinking Port is receiving/ transmitting
data
OFF
Port hasn't established valid
network connection
【Specification】
Panel
Gigabit fiber port 1000Base-
FX, optional
SC/ST/FC
Gigabit SFP
1000Base-X SFP
Gigabit Copper Port 10/100/1000 Base-T(X)
self-adapting RJ45 port, half/full
duplex self-
adaption or forced
working mode, support MDI/
MDI-X self-adaption
Gigabit POE copper
port
10/100/1000Base-
T(X) RJ45,
automatic flow control, full/half
duplex mode, MDI/ MDI-X
autotunning, POE port, output
power of 15W or 30W.
POE pin V+, V+, V-, V- are
corresponding to 1, 2, 3, 6.
Indicator Power indicator, PoE indicator,
interface indicator
Power supply
Input power supply 12~48VDC power supply,
support non-polarity
48VDC power supply:
44~55VDC, support
anti-reverse connection
220VAC power supply:
100~240VAC
Access terminal block 3-
pin 7.62mm pitch terminal
blocks
Switch Property
Backplane bandwidth
9.125G
MAC address
2K
Power consumption
Model III, Model IV No-load: ≤1.4W@48VDC
Full-load: ≤100.6W@48VDC
Working Environment
Working temperature
-40
~
75℃
Storage temperature
-40
~
85
℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)

Other 3One data Switch manuals

3One data IES5028-4GS-2F User manual

3One data

3One data IES5028-4GS-2F User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES7120G Series User manual

3One data

3One data IES7120G Series User manual

3One data PS5026G-2GS-24PoE User manual

3One data

3One data PS5026G-2GS-24PoE User manual

3One data IES2010 Series User manual

3One data

3One data IES2010 Series User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data PS5010G-2GS-8PoE User manual

3One data

3One data PS5010G-2GS-8PoE User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data IES215-1GX-4G User manual

3One data

3One data IES215-1GX-4G User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES1028 Series User manual

3One data

3One data IES1028 Series User manual

3One data IES5024-P User manual

3One data

3One data IES5024-P User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES5028-4GS User manual

3One data

3One data IES5028-4GS User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IES3016 Series User manual

3One data

3One data IES3016 Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

3One data MES600 Series User manual

3One data

3One data MES600 Series User manual

3One data ES209G-1GF User manual

3One data

3One data ES209G-1GF User manual

Popular Switch manuals by other brands

Avaya 4000 Series Troubleshooting instructions

Avaya

Avaya 4000 Series Troubleshooting instructions

D-Link xStack reference guide

D-Link

D-Link xStack reference guide

Steren 550-010 installation guide

Steren

Steren 550-010 installation guide

Graco 24Z978 instructions

Graco

Graco 24Z978 instructions

Schmalz VS-V-D-PNP operating instructions

Schmalz

Schmalz VS-V-D-PNP operating instructions

Leonton ET2-1002-2C Series user manual

Leonton

Leonton ET2-1002-2C Series user manual

SUCO 0340 Series operating instructions

SUCO

SUCO 0340 Series operating instructions

AKG HUB4000 Q User instructions

AKG

AKG HUB4000 Q User instructions

Lucent Technologies OptiStar EdgeSwitch User's operation guide

Lucent Technologies

Lucent Technologies OptiStar EdgeSwitch User's operation guide

Altimium SCA51T user manual

Altimium

Altimium SCA51T user manual

Pepperl+Fuchs LVL-M4 instruction manual

Pepperl+Fuchs

Pepperl+Fuchs LVL-M4 instruction manual

AKG HUB 4000 Q User instructions

AKG

AKG HUB 4000 Q User instructions

IFM Electronic efector 150 KA installation instructions

IFM Electronic

IFM Electronic efector 150 KA installation instructions

Edimax ES-5500M V2 datasheet

Edimax

Edimax ES-5500M V2 datasheet

H3C S5560X-HI Series installation guide

H3C

H3C S5560X-HI Series installation guide

Mosa SIP 4600B user manual

Mosa

Mosa SIP 4600B user manual

Rose electronics Vista Mini Installation and operation manual

Rose electronics

Rose electronics Vista Mini Installation and operation manual

ADC RF Worx user manual

ADC

ADC RF Worx user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.