manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data ICS5530 Series User manual

3One data ICS5530 Series User manual

This manual suits for next models

2

Other 3One data Switch manuals

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data IES2305 Series User manual

3One data

3One data IES2305 Series User manual

3One data ES1026-2F User manual

3One data

3One data ES1026-2F User manual

3One data ICS5428 Series User manual

3One data

3One data ICS5428 Series User manual

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

3One data IES6220 Series User manual

3One data

3One data IES6220 Series User manual

3One data ES5026 User manual

3One data

3One data ES5026 User manual

3One data ES209G-1GF User manual

3One data

3One data ES209G-1GF User manual

3One data TNS5500 Series User manual

3One data

3One data TNS5500 Series User manual

3One data ICS5000-E24GP4GS User manual

3One data

3One data ICS5000-E24GP4GS User manual

3One data ICS6400-12GT12GS4XS User manual

3One data

3One data ICS6400-12GT12GS4XS User manual

3One data IES1024 Series User manual

3One data

3One data IES1024 Series User manual

3One data IES2010 Series User manual

3One data

3One data IES2010 Series User manual

3One data IES5028G Series User manual

3One data

3One data IES5028G Series User manual

3One data IES215 Series User manual

3One data

3One data IES215 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES6320 Series User manual

3One data

3One data IES6320 Series User manual

3One data IES615-2DI(3IN1) Series User manual

3One data

3One data IES615-2DI(3IN1) Series User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ICS5530 Series
Industrial Core Layer 3 Ethernet
Switch
Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Song Bai Road, Nanshan
District, Shenzhen, 518108, China
Website:
www.3onedata.com
Te l:
+86 0755-26702688
Fax:
+86 0755-26703485
【
Package Checklist
】
Please check the integrity of package and accessories while
first using the switch.
1. Industrial Ethernet switch
2. Serial port line
3. Power line x2 (AC products only)
4. Foot pad x4
5. Rack-mounting lug x2
6. Warranty card
7. Certification
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【
Product Overview
】
This series are managed industrial Ethernet switches. The
models are:
Model I: ICS5530-16GS8GC6XS-2P220 (6 10GbE SFP
(10Gigabit/Gigabit self-adaption) + 8 Gigabit
combo+16 Gigabit SFP, 100~240VAC /DC
redundant power input)
Model II: ICS5530-16GS8GC6XS-2P (6 10GbE SFP
(10Gigabit/Gigabit self-adaption) + 8 Gigabit
combo+16 Gigabit SFP, 18~72VDC redundant
power input)
【
Panel Design
】
Front panel
Model I, Model II
Rear panel
Model I
Model II
1. Ethernet port indicator
2. Gigabit Ethernet SFP
3. 1000M Combo port
4. 10 Gigabit SFP + port (10Gigabit / Gigabit
self-adaption)
5. Console port
6. Power indicator (P1/P2)
7. Alarm indicator
8. Device running status indicator
9. Restoring factory setting button
10. Lugs
11. Relay output terminal blocks
12. AC power input
13. Grounding screw
14. DC power input
【
Mounting Dimension
】
Unit: mm
Notice before Mounting:
Don't place or install the device in area near water or
moisture, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before powering on the device, check the power
specifications supported by the device to prevent
device damage due to overvoltage.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【
Install Rack-mounted Device
】
This product adopts rack-mounting, mounting steps as
below:
Step 1 Select the device mounting location to ensure
enough size.
Step 2 Adopt 4 bolts to install the mounting lugs in the
device position as figure below.
Step 3 Place the device in the rack; adopt 4 bolts to fix
two sides mounting lugs in the rack.
Step 4 Check and confirm the product is mounted firmly
on the rack, then mounting ends.
【
Disassembling Device
】
Step 1 Power off the device.
Step 2 Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Step 3 Shift out the device from rack, disassembling
ends.
Notice before Powering on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug and power on.
Power switch “—” means power ON, “O” means
power OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device
and the power cord. Please notice the operation order
above.
【
Power Supply Connection
】
AC power supply
Model I provides 2 AC power supply access
interfaces which come with a switch.
Power supply range: 100~240VAC/DC.
DC power supply
Model II supports 2 DC power input
interfaces, and adopts 5-pin 5.08mm
pitch terminals, and the power supply
occupies the left 3 pins. The power supply supports
anti-reverse connection and dual power supply redundancy,
and the pin definitions of power supply are shown in the left
figure. Power input range: 18~72VDC.
【
Restore Default Settings
】
RESET is restoring default settings button. Device Restoring
default settings steps as follows: press and hold the RESET
button, power on the device again, wait for about 3~4
seconds to restore the factory settings.
【
Relay Connection
】
R+ and R- are the relay alarm output
section. They are open circuit in normal
non alarm state, closed when any alarm
information occurs. The product supports 2-way relay alarm
output, externally connected to alarm lights or alarm buzzer
or other switching value collecting device in order to timely
notify operators when the alarm occurs.
【
Console Port Connection
】
The device provides 1 program debugging port based on
RS-232 serial port which can conduct device CLI command
management after connecting to PC. The interface adopts
RJ45 port, and the RJ45 pin definitions are as follows:
Pin No.
2
3
5
Definition
TXD
RXD
GND
【
Checking LED Indicator
】
The series product provides LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
Description
P1
ON
PWR is connected and
running normally
OFF Power supply is disconnected
or running abnormally
P2
ON
PWR is connected and
running normally
OFF Power supply is disconnected
or running abnormally
RUN
Blinking
The system is running
normally
OFF The system is not running or
running abnormally
ON
System is running abnormally
ALM
ON
Power supply, port link alarm
OFF Power supply, port link without
alarm
Link
(G1-G24,
X1-X6)
ON
Port has established valid
network connection
Blinking
Port is in a network
communication status
OFF
Port hasn’t established valid
network connection.
【
Logging in to WEB Interface
】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below.
Step 1 Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually
accessed.
Step 2 Enter device’s IP address in the address bar of
the computer browser.
Step 3 Enter device’s username and password in the
login window as shown below.
Step 4 Click “OK” button to login to the WEB interface of
the device.
Note:
The default IP address of the device is
“192.168.1.254”.
The default username and password of the device are
“admin123”.
If the username or password is lost, user can restore it
to factory settings via device DIP switch or
management software; all modified configurations
will be cleared after restoring to factory settings, so
please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【
Specification
】
Panel
10GbE interface 10GbE SFP+ port (10Gigabit /
Gigabit self-adaption)
1000M Combo port 10/100/1000Base-T(X) RJ45
or 100/1000 Base-X SFP
interface (optional)
Gigabit SFP
100/1000Base-X SFP slot
Console port
CLI command management
port (RS-232), RJ45
Alarm interface 5-pin 5.08mm pitch terminal
block (R+/R-), support 2 relay
alarm information outputs
Indicator Power indicator, system alarm
indicator, device running
status indicator, interface
connection/running status
indicator
Switch Property
Backplane bandwidth
168G
Buffer size
16Mbit
MAC address table
16K
Power Supply
Model I Input power: 100~240VAC/DC
Access terminal: support
single-
phase socket with
rocker switch
Model II Input power: 18~72VDC
Access terminal: adopt 5-pin
5.08mm pitch terminal blocks
(power supply occupies 3
pins)
Power Consumption
Model I No-load: 21.1W@220VAC
Full-load:37.8W@220VAC
Working Environment
Working temperature
-40~75
℃
Storage temperature
-40~85℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)
【
Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)
】
(Applicable in the EU-member states)
The crossed-out wheeled bin
symbol on the equipment or
its packaging indicates that
the product, at the end of its
service life, shall not be
mixed with unsorted
municipal waste but should
be collected separately, in
accordance with local laws
and regulations.
A proper separate collection of end-of-life equipment for the
subsequent recycling, treatment and environmentally
compatible disposal, will help prevent potential damage to
the environment and human health, facilitating the reuse,
recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.
Users’ cooperation in the correct disposal of this product will
contribute to saving valuable resources and protecting the
environment.