ABB H81381P Series User manual

2TMD041800D0010 │07.12.2020
Product manual
ABB-Welcome IP
H81381P.-. IP pushbutton outdoor station

Inhaltsverzeichnis
Product manual
2TMD041800D0010
│
2
Inhaltsverzei chnis
1Notes on the instruction manual............................................................................................................4
2Safety..................................................................................................................................................4
3Intended use........................................................................................................................................5
4Environment.........................................................................................................................................6
4.1 ABB devices..............................................................................................................................6
5Product description...............................................................................................................................7
5.1 Device type ...............................................................................................................................7
5.2 Control elements........................................................................................................................8
5.3 Terminal description...................................................................................................................9
5.4 Lock type and connection.........................................................................................................10
6Technical data....................................................................................................................................11
7Mounting/Installation...........................................................................................................................12
7.1 Requirement for the electrician.................................................................................................12
7.2 Mounting.................................................................................................................................13
7.2.1 Preparation .......................................................................................................................... 13
7.2.2 Installation height.................................................................................................................. 13
7.2.3 Surface-mounted installation................................................................................................. 15
7.2.4 Flush-mounted installation .................................................................................................... 16
7.2.5 Cavity wall installation........................................................................................................... 18
7.2.6 Dismantling.......................................................................................................................... 19
7.2.7 Replacing the nameplate ...................................................................................................... 19
8Commissioning...................................................................................................................................20
9Operation...........................................................................................................................................22
9.1 Call a resident..........................................................................................................................22
9.2 Call a guard unit ......................................................................................................................23
9.3 Turn on a light..........................................................................................................................24
10 Cyber security....................................................................................................................................25
10.1 Disclaimer ...............................................................................................................................25
10.2 Performance and service .........................................................................................................25
10.3 Deployment guideline...............................................................................................................26
10.4 Upgrading................................................................................................................................26
10.5 Backup/Restore.......................................................................................................................26
10.6 Malware prevention solution.....................................................................................................26
10.7 Password rule..........................................................................................................................26
11 Notice................................................................................................................................................27

Inhaltsverzeichnis
Product manual
2TMD041800D0010
│
3

Notes on the instruction manual
Product manual
2TMD041800D0010
│
4
1Notes on the instruction manual
Please read through this manual carefully and observe the information it contains. This will
assist you in preventing injuries and damage to property and ensure both reliable operation and
a long service life for the device.
Please keep this manual in a safe place. If you pass the device on, also pass on this manual
along with it. ABB accepts no liability for any failure to observe the instructions in this manual.
2Safety
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 100-240 V supply system to be performed only by
specialist staff!

Intended use
Product manual
2TMD041800D0010
│
5
3Intended use
As part of the ABB-Welcome IP system, this device can only be used with accessories from that
system.
Security mode
This outdoor station runs in "Security mode" by default to guarantee high security.
In "Security mode", this outdoor station requires a certificate issued by the management
software before it can function normally.
Compatible mode
If there is no management software, this outdoor station needs to run in "Compatible mode" to
function normally. This can be set on the indoor station. Please refer to the product manual for .
IP touch 7".
Video privacy
Video privacy
Making and saving video recordings can infringe on personal rights! Always
observe the applicable legal and labeling requirements for the placement and
operation of video components!

Environment
Product manual
2TMD041800D0010
│
6
4Environment
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with household
waste.
– The device contains valuable raw materials that can be recycled. Therefore,
dispose of the device at the appropriate collecting facility.
4.1 ABB devices
All packaging materials and devices from ABB bear the markings and test seals for proper
disposal. Always dispose of the packing materials and electric devices and their components via
an authorized collection facility or disposal company.
ABB products meet the legal requirements, in particular the laws governing electronic and
electrical devices and the REACH ordinance.
(EU-Directive 2012/19/EU WEEE and 2011/65/EU RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006)

Product description
Product manual
2TMD041800D0010
│
7
5Product description
5.1 Device type
Article
number Product ID Product name Colour Size (HxWxD)
Unit: mm
H81381P1-S 2TMA130010X0001 OS, IPpush, 1 gang Stainless
steel 135 x 277 x 29
H81381P2-S 2TMA130010X0002 OS, IPpush, 2 gang Stainless
steel 135 x 277 x 29
H81381P3-S 2TMA130010X0003 OS, IPpush, 3 gang Stainless
steel 135 x 277 x 29

Product description
Product manual
2TMD041800D0010
│
8
5.2 Control elements
No. Function
1Camera
2 Speaker and microphone integration
3Round pushbutton
4End strip
1
2
3
4

Product description
Product manual
2TMD041800D0010
│
9
5.3 Terminal description
No. Function
1Reset button
2Micro USB update connector
3 Plug-in clamps (DC+...GND) for standalone power supply
4 Plug-in clamps (LOCK...GND) for door opener
5 Plug-in clamps (COM...NC...NO) for floating output, door opener
6LAN (PoE)
7Connector for next module
8 Connector for exit button
9 Connector for the sensor used for door status detection
10 Connector for 5" display module
11 Connector for previous module
7
11
1
2 3
4
5
6
7
8
9
10

Product description
Product manual
2TMD041800D0010
│
10
5.4 Lock type and connection
Lock type Pic Operation type Voltage Wiring type
Electrical strike
lock, 12V Power on to open 12 V
⎓
/~ Type A/B
Electrical strike
lock, 24V Power on to open 24 V
⎓
/~ Type B
Electrical rim
lock, 12 V Power on to open 12 V
⎓
Type A/B
Electrical
mortise lock Power off to open 12 V
⎓
Type C
Magnetic lock Power off to open 12/24 V
⎓
Type C
GND
NO
DC+
NC
LOCK
COM
GND
NO
DC+
NC
LOCK
COM
GND
NO
DC+
NC
LOCK
COM
+
++
-
-
-
PS
PS
TypeA
Type B
Type C

Technical data
Product manual
2TMD041800D0010
│
11
6Technical data
Designation Value
Rating voltage 24 V DC
Operating voltage range 20-27 V DC
Rating current 27 V DC, 300 mA
24 V DC, 330 mA
Operating temperature -40 °C…+55 °C
Product dimensions 135mm x 276.9 mm × 17.6 mm
Camera type CMOS
Camera viewing angle 130°
Resolution ratio HD (1280 x 720 pixel)
Power supply for door opener 18 V, 4 A impulse, max. 250 mA holding
Floating output for door opener 230 V AC, 3 A
30 V DC, 3 A
Video codec H.264
Audio codec G.711
IP level IP 54
IK level IK 07
Network connection standard IEEE 802.3, 10Base-T/100Base-TX, auto MDI/MDI-X

Mounting/Installation
Product manual
2TMD041800D0010
│
12
7Mounting/Installation
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect
contact with live components.
This can result in electric shock, burns or even death.
– Disconnect the mains power supply prior to installation and/or disassembly!
– Permit work on the 100-240 V supply system to be performed only by
specialist staff!
7.1 Requirement for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
– Incorrect installation endangers your life and that of the user of the electrical
system.
– Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation
are as follows:
– Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect
2. Secure against being re-connected
3. Ensure there is no voltage
4. Connect to earth and short-circuit
5. Cover or barricade adjacent live parts.
– Use suitable personal protective clothing.
– Use only suitable tools and measuring devices.
– Check the type of supply network (TN system, IT system, TT system) to
secure the following power supply conditions (classic connection to ground,
protective grounding, necessary additional measures, etc.).

Mounting/Installation
Product manual
2TMD041800D0010
│
13
7.2 Mounting
7.2.1 Preparation
Use gloves to protect yourself against cuts.
7.2.2 Installation height
1.5 m
5 feet

Mounting/
Installation
Product manual
2TMD041800D0010
│
14
Note
The following installation situations must be avoided without fail to ensure
picture quality:
■Direct light
■Direct sunlight
■Extremely bright picture background
■Highly reflective walls on the opposite side of the door station
■Lamps or direct light sources

Mounting/Installation
Product manual
2TMD041800D0010
│
15
7.2.3 Surface-mounted installation
3
4
5
6
78
2
1
32 mm
40mm
71mm
211 mm
1X3

Mounting/Installation
Product manual
2TMD041800D0010
│
16
7.2.4 Flush-mounted installation
1. Flush-mounted without pre-installation box
2
1
3
117 mm 46 mm
2
6
4
m
m
1X3
4
5
6
7
89

Mounting/Installation
Product manual
2TMD041800D0010
│
17
2. Flush-mounted with pre-installation box
3
21
2
7
4
m
m
126 mm
68mm
1X3
10
5
6
7
8
9
4

Mounting/Installation
Product manual
2TMD041800D0010
│
18
7.2.5 Cavity wall installation
1
23
4
10
5
6
7
8
9
6
5

Mounting/Installation
Product manual
2TMD041800D0010
│
19
7.2.6 Dismantling
7.2.7 Replacing the nameplate
1
2
3

Commissioning
Product manual
2TMD041800D0010
│
20
8Commissioning
The outdoor station must be configured via the indoor station.
Step1: Outdoor station enters engineering mode
■Power on the outdoor station, wait a while until all 3 LED indicators go out.
■Hold the first button on the outdoor station for 10 s until all 3 LED indicators start to flash.
Tip
The outdoor station will quit engineering mode after 5 minutes.
Step 2: Indoor station enters engineering mode
On the extra screen on the indoor station, click "System" to enter the settings screen.
This manual suits for next models
3
Table of contents
Other ABB Intercom System manuals

ABB
ABB M22343 Series User manual

ABB
ABB M22302 series User manual

ABB
ABB 83210-AP 500 Series User manual

ABB
ABB Welcome IP User guide

ABB
ABB Welcome M2303 User manual

ABB
ABB H8303 User manual

ABB
ABB CM-06DN Series User manual

ABB
ABB M22311 Series User manual

ABB
ABB M22341 Series User manual

ABB
ABB Welcome IP HSM36-GU User manual

ABB
ABB ABB-Welcome User manual

ABB
ABB Welcome M2233 Series User manual

ABB
ABB H8131xPx-A User manual

ABB
ABB ABB-Welcome M2240-W User manual

ABB
ABB M2304 User manual

ABB
ABB Video kit User manual

ABB
ABB M22301 series User manual

ABB
ABB WelcomeTouch 83220-SM 500 Series User manual

ABB
ABB 83210-AP-xxx-500 User manual

ABB
ABB DP7-S-611 User manual