manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Control Unit
  8. •
  9. ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN Job Aid+ 1442704PG2 User manual

jobAid
DESCRIPTION
TheSmallForm‐FactorPluggableOC‐12Bidirectional1550/1310
nm(BidirectionalSFP)plugsintoADTRANequipmentdesigned
toacceptSmallForm‐factorPluggables(SFPs).Installedintoan
appropriatehostunit,theBidirectionalSFPprovidesanOC‐12
interfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheBidirectionalSFP:
SONETOC‐12compatible(622Mb/s),single‐fiberoperation
15kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPssupplied
byADTRANaretobeusedwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherSFPs.
Small Form-Factor Pluggable OC-12
Bidirectional 1550/1310 nm
SPECIFICATIONS
OpticalSpecifications:
Opticaltransmitlevel:–8dBmto–15dBm
Opticalreceivelevel:–8dBmto–28dBm
TransmitWavelength:1550nm
ReceiveWavelength:1310nm
Opticalbudget:12(±1)dBm
Opticalconnectors:LC
ExtendedEnvironmentalSupport:
Operationaltemperaturerange:–40°Cto+65°C
Storagetemperaturerange:–40°Cto+85°C
Relativehumidityto95%,noncondensing
INSTALLATION
Before installing the equipment, inspect the Bidirectional SFP. If
damage has occurred during shipping, file a claim with the
carrier, and then contact ADTRAN Customer Support. For more
information, refer to the warranty.
Installation Guidelines
The following are guidelines for this installation.
Do not remove the protective end cap from the SFP until the
fiber optic cable is ready to be connected.
Ensure that the manufacturer’s label on the SFP is facing
upward for correct installation.
Installation Steps
ToinstalltheBidirectionalSFPintoanappropriatemodule,
completethefollowingsteps:
1. InserttheBidirectionalSFPintotheSFPcageonthemodule.
2. Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheBidirectionalSFPallthewayintothereceptacle
untilthereisanaudible“click”.
NOTE
ToremovetheSFPfromthecageonthecircuitcard,usethelatch
ontheSFP.
CLEI: S00TALBJ__
Product P/N: 1442704PG2
Issue Date: May 2014
Document P/N: 61442704PG2-22B
Documentation for ADTRAN Carrier Networks products is available for
viewing and download directly from the ADTRAN Support Community
website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including customized
training and courses taught at our facilities or at customer sites.
For inquiries, go to: http://adtran.com/training
The following documents provide additional information for this product:
SFP/XFP/SFP+ Compatibility Matrix and Engineering Guide
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2014 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442704PG2-22B*
SAFETY AND REGULATORY COMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewrist
straptopreventdamagetoelectroniccomponents.Place
modulesinantistaticpackingmaterialwhentransportingor
storing.Whenworkingonmodules,alwaysplacethemonan
approvedantistaticmatthatiselectricallygrounded.
Thisproductmeetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSI
EN300368.TheproductisintendedfordeploymentinCentral
Officetypefacilities,EEEs,EECs,andlocationswherethe
NECapplies(forexample,CustomerPremises).Theproductis
tobeinstalledinADTRANproductsinRestrictedAccess
Locationsonly,andinstalledbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
PerGR‐1089‐COREtheADTRANsystemthattheproductis
beingdeployedinisdesignedandintendedforinstallationas
partofaCommonBondingNetwork(CBN).TheADTRAN
systemthattheproductisbeingdeployedinisnotdesigned
norintendedforinstallationaspartofanIsolatedBonding
Network(IBN).
PerGR‐1089‐CORESection9,theproductdoesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheproductcanbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheproductisproperlygroundedviathe
backplaneconnector.
CAUTION
C
ThisproductisaClass1LaserProductandcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.11,EN60825‐1,
andEN60825‐2.TheproductisNRTLListedandCBCertifiedto
allapplicableAmericanandEuropeansafetystandards.
NOTE
TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐CORE.
Theproductisdesignedtomeetthefollowingenvironmental
classes:
ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.
NOTE
ThisproductiscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
ThisproductiscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1,2,and3,asdefinedinGR‐3108‐CORE.

Other ADTRAN Control Unit manuals

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN Total Access 1500 Instruction Manual

ADTRAN

ADTRAN Total Access 1500 Instruction Manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN SFP GPON ONU User manual

ADTRAN

ADTRAN SFP GPON ONU User manual

ADTRAN 1200261L1 User manual

ADTRAN

ADTRAN 1200261L1 User manual

ADTRAN Total Access 300 User manual

ADTRAN

ADTRAN Total Access 300 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN MX2820 SCU User manual

ADTRAN

ADTRAN MX2820 SCU User manual

ADTRAN Job Aid+ 1442940G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442940G1 User manual

ADTRAN Quad T1 User manual

ADTRAN

ADTRAN Quad T1 User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN Octal BRI/U User manual

ADTRAN

ADTRAN Octal BRI/U User manual

ADTRAN Total Access 300 Series Product manual

ADTRAN

ADTRAN Total Access 300 Series Product manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN

ADTRAN Job Aid+ 1442981G8C User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.