jobAid
DESCRIPTION
TheSmallForm‐FactorPluggableOC‐12Bidirectional1550/1310
nm(BidirectionalSFP)plugsintoADTRANequipmentdesigned
toacceptSmallForm‐factorPluggables(SFPs).Installedintoan
appropriatehostunit,theBidirectionalSFPprovidesanOC‐12
interfacetothesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheBidirectionalSFP:
SONETOC‐12compatible(622Mb/s),single‐fiberoperation
15kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,onlySFPssupplied
byADTRANaretobeusedwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherSFPs.
Small Form-Factor Pluggable OC-12
Bidirectional 1550/1310 nm
SPECIFICATIONS
OpticalSpecifications:
Opticaltransmitlevel:–8dBmto–15dBm
Opticalreceivelevel:–8dBmto–28dBm
TransmitWavelength:1550nm
ReceiveWavelength:1310nm
Opticalbudget:12(±1)dBm
Opticalconnectors:LC
ExtendedEnvironmentalSupport:
Operationaltemperaturerange:–40°Cto+65°C
Storagetemperaturerange:–40°Cto+85°C
Relativehumidityto95%,noncondensing
INSTALLATION
Before installing the equipment, inspect the Bidirectional SFP. If
damage has occurred during shipping, file a claim with the
carrier, and then contact ADTRAN Customer Support. For more
information, refer to the warranty.
Installation Guidelines
The following are guidelines for this installation.
Do not remove the protective end cap from the SFP until the
fiber optic cable is ready to be connected.
Ensure that the manufacturer’s label on the SFP is facing
upward for correct installation.
Installation Steps
ToinstalltheBidirectionalSFPintoanappropriatemodule,
completethefollowingsteps:
1. InserttheBidirectionalSFPintotheSFPcageonthemodule.
2. Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheBidirectionalSFPallthewayintothereceptacle
untilthereisanaudible“click”.
NOTE
ToremovetheSFPfromthecageonthecircuitcard,usethelatch
ontheSFP.
CLEI: S00TALBJ__
Product P/N: 1442704PG2
Issue Date: May 2014
Document P/N: 61442704PG2-22B
Documentation for ADTRAN Carrier Networks products is available for
viewing and download directly from the ADTRAN Support Community
website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including customized
training and courses taught at our facilities or at customer sites.
For inquiries, go to: http://adtran.com/training
The following documents provide additional information for this product:
SFP/XFP/SFP+ Compatibility Matrix and Engineering Guide
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2014 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442704PG2-22B*
SAFETY AND REGULATORY COMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewrist
straptopreventdamagetoelectroniccomponents.Place
modulesinantistaticpackingmaterialwhentransportingor
storing.Whenworkingonmodules,alwaysplacethemonan
approvedantistaticmatthatiselectricallygrounded.
Thisproductmeetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSI
EN300368.TheproductisintendedfordeploymentinCentral
Officetypefacilities,EEEs,EECs,andlocationswherethe
NECapplies(forexample,CustomerPremises).Theproductis
tobeinstalledinADTRANproductsinRestrictedAccess
Locationsonly,andinstalledbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
PerGR‐1089‐COREtheADTRANsystemthattheproductis
beingdeployedinisdesignedandintendedforinstallationas
partofaCommonBondingNetwork(CBN).TheADTRAN
systemthattheproductisbeingdeployedinisnotdesigned
norintendedforinstallationaspartofanIsolatedBonding
Network(IBN).
PerGR‐1089‐CORESection9,theproductdoesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheproductcanbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheproductisproperlygroundedviathe
backplaneconnector.
CAUTION
C
ThisproductisaClass1LaserProductandcomplieswiththe
LaserSafetyrequirementsofFDA21CFR1040.11,EN60825‐1,
andEN60825‐2.TheproductisNRTLListedandCBCertifiedto
allapplicableAmericanandEuropeansafetystandards.
NOTE
TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐CORE.
Theproductisdesignedtomeetthefollowingenvironmental
classes:
ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
ThisproductmeetsEURoHSDirective2002/95/ECand/orappli‐
cableexemptions.Refertowww.adtran.comforfurtherinfor‐
mationonRoHS/WEEE.
NOTE
ThisproductiscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
ThisproductiscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
ThisproductisdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1,2,and3,asdefinedinGR‐3108‐CORE.

Other ADTRAN Control Unit manuals

ADTRAN 1200791L1 User manual

ADTRAN

ADTRAN 1200791L1 User manual

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN T3 User manual

ADTRAN

ADTRAN T3 User manual

ADTRAN E220 HFAC HDSL Product manual

ADTRAN

ADTRAN E220 HFAC HDSL Product manual

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN

ADTRAN E220 HFAC HDSL Instruction Manual

ADTRAN Quad E1/PRA User manual

ADTRAN

ADTRAN Quad E1/PRA User manual

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN

ADTRAN OC-48/STM-16 DWDM SFP User manual

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN 1442442F1 User manual

ADTRAN

ADTRAN 1442442F1 User manual

ADTRAN Quad T1 User manual

ADTRAN

ADTRAN Quad T1 User manual

ADTRAN 1200222L1 User manual

ADTRAN

ADTRAN 1200222L1 User manual

ADTRAN MX2820 SCU User manual

ADTRAN

ADTRAN MX2820 SCU User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN E1 User manual

ADTRAN

ADTRAN E1 User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN NetVanta Octal T1/E1 Wide Module User manual

ADTRAN

ADTRAN NetVanta Octal T1/E1 Wide Module User manual

ADTRAN Total Access 300 User manual

ADTRAN

ADTRAN Total Access 300 User manual

ADTRAN 1200315L1 User manual

ADTRAN

ADTRAN 1200315L1 User manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN

ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN 1200065L1-1 User manual

ADTRAN

ADTRAN 1200065L1-1 User manual

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G1 User manual

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G3 User manual

Popular Control Unit manuals by other brands

Intermatic K4141C Series quick start guide

Intermatic

Intermatic K4141C Series quick start guide

Siemens PLC-4 installation instructions

Siemens

Siemens PLC-4 installation instructions

Crestron CWD6609 Operation guide

Crestron

Crestron CWD6609 Operation guide

Exhausto MCCW Product Instruction

Exhausto

Exhausto MCCW Product Instruction

oventrop REGTRONIC PC Assembly and operation manual

oventrop

oventrop REGTRONIC PC Assembly and operation manual

JARDIBRIC WF-IS6 Quick installation guide

JARDIBRIC

JARDIBRIC WF-IS6 Quick installation guide

Festo VMPA1-HS Assembly instructions

Festo

Festo VMPA1-HS Assembly instructions

Ranco ETC-211000-000 installation instructions

Ranco

Ranco ETC-211000-000 installation instructions

Avid Technology HDX-192 Cooling Kit installation guide

Avid Technology

Avid Technology HDX-192 Cooling Kit installation guide

theobroma systems RK3399-Q7 user manual

theobroma systems

theobroma systems RK3399-Q7 user manual

ABB Tina 5A Original instructions

ABB

ABB Tina 5A Original instructions

Armstrong CD72SR Installation and operation manual

Armstrong

Armstrong CD72SR Installation and operation manual

OSF POOL-Control-40 Installation and operating instructions

OSF

OSF POOL-Control-40 Installation and operating instructions

Link 450 Series installation instructions

Link

Link 450 Series installation instructions

Gemotech RemoDAQ-8017SV user manual

Gemotech

Gemotech RemoDAQ-8017SV user manual

Land Pride 380-137A Assembly instructions

Land Pride

Land Pride 380-137A Assembly instructions

Emerson FISHER Enardo 450 Series instruction manual

Emerson

Emerson FISHER Enardo 450 Series instruction manual

ENGO CONTROLS ECB02M230 quick guide

ENGO CONTROLS

ENGO CONTROLS ECB02M230 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.