Place finger on the sensor surface
Place finger in the center of the sensor.
Illustration for placing fingerprint
Other Setup
Item Explanation
Factory default
setting
Any
RF+PW
RF+FP
PW+FP
Fingerprint only, Card only or ID+Password only
It requires both Card and Password verification
together
It requires both Card and Fingerprint
verification together
It requires both Password and Fingerprint verification
together
Enter the user ID first then verify the fingerprint
Any
ID+FP
15
Place finger straight and
flat on the sensor. Insure
maximum sensor coverage.
Card Access control
Front View
10-29-09 THU
14:03 09
IN
Fingerprint Access control
Front View
180mm
10-29-09 THU
14:03 09
IN
80mm 40mm
Side View
Press [M] key to enter system management menu.
(This requires the administrator authorization if there is admin
registered in the system.) Menu List:
Menu List
Operation Guide
Reader Appearance
Cancel/Power Key
Exit/Cancel the Present
Operation
Power on/Power off
State Key(Clock In)/Up
Confirm Key
Confirm Present Operation
State Key(Clock Out)/Down
Door Bell Key
Workcode Setup Key
Menu Key
Enter System Management Menu
Num. Keys
Enter Employee ID or Password
0-9
Door Alert
User
System Info User, FP, Log, Serial,FirmVer
Enroll
Delete
Admin Setup
Admin Clear
Setup
Hardware Test Keypad, LCD, Sensor, Flash
System
Time
Language
Net
Precision
Auto Off
Auto Update
Image Disp.
Log Setup Log Alert
Re-Verify
Verify Mode
Group Setup
IP Address
Subnet Mask
Gateway IP
MAC Address
Workcode Scope
Dev ID
Unlock
Mode
Server Port
Server IP
Enroll Card
Enroll Card
Swipe card!
008101-C
Cancel-C Sav-OK
Enroll
FP 1/2
Password/ Card
Esc-C Set-OK
Select [Card] Swipe the card Press [OK] to save
[OK]
press [OK]
(ID:000001-999999)
Enroll Fingerprint:
Place the same finger on the sensor twice in a row to enroll fingerprints.
Enroll Password:
Password length: 000000-999999
.
Enroll Card
:
Enroll User: Each user can register two fingerprints, one password and one RFID card.
1
Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of
two administrators to each unit.
2
Enroll
ID 008101
Esc-C Set-OK
IN
09 : 00
26
10-11-17 WED
MENU
User
Setup
USB Flash
User ▼
Enroll
Delete
Verify Mode
[M]
Select [User]
[OK]
Select [Enroll]
[OK]
Input user ID
Enroll PWD
PWDID ******
Esc-C Set-OK
Input password
008101-P
Cancel-C Sav-OK
Press [OK] to save
PWDID ******
Confm ******
Input password again
[OK] [OK] [OK]
Enroll
FP 1/2
Password /Card
Esc-C Set-OK
Select [Password]
press [OK]
Take Off! 008101-1
Cancel-C Sav-OK
Press [OK] to save
Take Off! Place Finger #2
Enroll FP
Enroll FP
Place Finger #1
Enroll fingerprint
[OK]
Enroll
1/2
Password/Card
Esc-C Set-OK
FP
Select [FP]
press [OK]
Admin Setup
ID 008101
Esc-C Add-OK
Admin Setup
008101
No-C Yes-OK
Admin Setup
Esc-C Add-OK
Admin Setup
ID 000000
MENU
User
Setup
USB Flash
User ▼
Admin Setup
Group Setup
Admin Clear
Select [User]
[OK]
Selelct [Admin Setup]
[OK] [OK] [OK] [OK]
Setup successfulInput Admin ID
Enroll FP Enroll FP Enroll FPEnroll FP
Enroll Card
Enroll PWD Enroll PWD
Tips: Group setup is used for managing the access control privileges. Each group can
contain 4 time zones.
Explanation
G01
Item
Factory default
setting
G00
G01
G02-16
The user in Group00 can not open the door
The user in Group01 can open the door anytime
It is according to the Group & Time zone setting which
can be set through the software
Group Setup:
M→[User]→[OK]→[Group Setup]→[OK]→[OK]→
Input employee ID→[OK]→Input the group ID→[OK]→[OK].
Explanation
1
Tips: It doesn’t allow duplicate Device ID in one LAN. Otherwise, it will cause software
communication error.
Item
Factory default
setting
1-99999999 Device ID of the unit which is required in software
communication
Dev ID:
M→[Setup]→[OK]→[System]→[OK]→[Dev ID]→[OK]→
Input the device’s ID→[OK]→[C]→[OK].
Explanation
Item
Factory default
setting
Server Mode
192.168.0.218
255.255.255.0
192.168.0.1
192.168.0.7
5010
Mode
IP Address
Subnet Mask
MAC Address
Gateway IP
Server IP
Server Port
Net:
M→ [Setup]→[OK]→[System]→[OK]→[Net]→[OK]→to select [Mode/IP Address/Subnet Mask
/MAC Address/Gateway IP/Server IP/Server Port]→[OK]→Modify parameters→[C]→[OK].
Explanation
5
Item
Factory default
setting
1-15 The duration of the audible alarm to notify employees
of events. (Lunch, break, Off Duty)
No
No
It generates a door close signal immediately after
it generates the door open signal
Unlock:
M→ [Setup]→[OK]→[System]→[OK]→[Unlock]→[OK]→No/1~15→[OK]→
[C]→[OK]. ‘No’-no delay time; The maximum delay time is 15 seconds.
Explanation
It generates the door open alarm signal if the door open
time is longer than the preset value
Disable the door open alarm
Item
Factory default
setting
1-99
Door Alert:
M→ [Setup]→[OK]→[System]→[OK]→[Door Alert]→[OK]→
to select No/1~99→[OK]→[C]→[OK]. ‘No’-no alert signal.
Tips: WorkCode indicates the work type,easily distinguishes which attendance record
is related to which work type.
Explanation
Max 999999
Min 0
Item
Factory default
setting
0-999999 Valid scope for the Workcode
WorkCode:
M→ [Setup]→[OK]→[System]→[OK]→[WorkCode Scope]→[OK]
→Input Max→[OK]→Input Min→[OK] →[C]→[OK].
Verify Mode:
M→[User]→[OK]→[Verify Mode]→[OK]→[OK]→Input employee ID→[OK]→
Use [ /IN]/[OUT/ ] to select ‘ANY/RF+FP/PW+FP/RF+PW/ID+FP’→[OK]→[OK].
Explanation
Related Language
Item
Factory default
setting
Languages
Optional 4 languages.
Language:
M→[Setup]→[OK]→[System]→[OK]→[Language]→[OK]→
Use [ /IN]/[OUT/ ] to select ENG/FRCH/GERM/...→[OK]→[C]→[OK].
TCP/IP Server mode: Common network mode
TCP/IP Client mode: Only communicate
with the PC which has static IP
Set terminal IP address when communication
of TCP/IP, IP address
must be a static
IP address
Subnet Mask of the LAN
Unique Physical address of the network moudle. This
setting can not be modified.
Default Gateway of the LAN
The IP address of the Sever Machine
when using Client Mode TCP/IP
communication.
It’s the Software Port number used when the
read is configured for TCP/IP communication
Installation Diagram
Installation Step
Access Control Reader & Power Supply Access Control Reader & Switch Power Supply
Access Control Reader & Controller Communication with PC
1
2
3
Drill holes in the wall follow the hole position on back panel
Install and fix back panel, connect related cables
Attach access control reader
Package List
12 6 5 4 32 1
+12V GND GND D1 D0 GND D1 D0
GND D1 D0
+12V GND
P1P4
Port
PIN
Function
Connector
Power
Connector Wiegand Input Wiegand Output
Wiegand Card Reader
Switch Power Supply Access Controller
Wiring Instruction
P1
P2
P
3
Relay
6
7
8
COM
NC
NO
P3
P3
Relay
6
7
8
COM
DC12V
DC12V
12V
COM
12V
COM
P
4
Relay State
P2
P3
P1
Function
Function
PIN Cable
Color Description
1
2
Green
White
Wiegand DATA0 Output
Wiegand DATA1 Output
3
4
5
6
Wiegand
Output
Wiegand
Input
Black
Yellow
Purple
Black
Wiegand DATA 0 Input
Wiegand DATA 1 Input
GND
GND
6
Blue
Cable
Color Description
1
2
3
4
Orange
5
Yellow
Black
Green
Data Wire
Wire
Purple
GND
RS 485 (A+)
RS 485 (B+)
Cable
Color
Function Description
1
2
3
4
5
6
7
8
Yellow
PIN
Door Sensor
Exit Button
Door Bell
GND
Relay
Purple
White
White
Black
Green
Orange
Blue
Trigger Input
Trigger Input
Trigger Input
Trigger Input
GND
COM
NC / DC12V
NO / DC12V
Relay State
1287654 3 2 1
+12V GND NO NC COM GND BE1 BE2 OPEN DOOR
+12V PUSH NO GND NC
P4 P3
GND
+
+
+
Port
PIN
Function
Power Supply
Output Controller GND Exit
Button
Door
Sensor
Power on to unlock
Door Bell
Door Sensor
Access Control Power Supply Power off to unlock
Mark
7 6 54 3 2 1
NC COM GND BE1 BE2 OPEN DOOR
+12V
P3
GND
Connector
Function
128
+12V GND NO
P4
+
Port
PIN
Connector
Power Supply
Output Controller GND Door Bell Exit
Button
Door
Sensor
Door Bell
Door Sensor
Switch Power Supply
Power off to unlock
Diode
Diode
Power on to unlock
Connector
Connector
Connector
P4
1
2
Function Description
PIN Cable
Color
Power Red
Black GND
DC 12V
Door Bell
Important notice: Please follow the wiring diagram as it is displayed. Damaged products due to
improper wiring are not covered under the product warranty.
Accessory Package Connector Jack
P1 P2 P3
P4
1
Reader
or
10-29-09
THU
14:03
09
IN
10-29-09
THU
14:03
09
IN
2Instruction Package
Black
Blue
Purple
Red
12V
COM
Relay State
12V
COM
Card
COMPACT
CD-ROM
ENCH
windows
FOR
Windows98
Windows2000
WindowsXP
WindowsVista
Windows7
...
Accesscontrol
1
2
3
+
7 6 52 1
RS485
TCP/IP
Mini USB
Select either
12 volt out on
COM or voltage
free contact.

Other manuals for VF30

1

This manual suits for next models

1

Other Anviz IP Access Controllers manuals

Anviz T5S User manual

Anviz

Anviz T5S User manual

Anviz T5 User manual

Anviz

Anviz T5 User manual

Anviz T50 User manual

Anviz

Anviz T50 User manual

Anviz T5 User manual

Anviz

Anviz T5 User manual

Anviz P7 User manual

Anviz

Anviz P7 User manual

Anviz M-Bio User manual

Anviz

Anviz M-Bio User manual

Anviz EP10 User manual

Anviz

Anviz EP10 User manual

Anviz OA200 User manual

Anviz

Anviz OA200 User manual

Anviz C2C User manual

Anviz

Anviz C2C User manual

Anviz W 1 User manual

Anviz

Anviz W 1 User manual

Anviz C2 User manual

Anviz

Anviz C2 User manual

Anviz CX2 User manual

Anviz

Anviz CX2 User manual

Anviz CX7 User manual

Anviz

Anviz CX7 User manual

Anviz TC550 User manual

Anviz

Anviz TC550 User manual

Anviz T5Pro User manual

Anviz

Anviz T5Pro User manual

Anviz VF30 User manual

Anviz

Anviz VF30 User manual

Anviz M5 PRO User manual

Anviz

Anviz M5 PRO User manual

Anviz T50 User manual

Anviz

Anviz T50 User manual

Anviz VP30 User manual

Anviz

Anviz VP30 User manual

Popular IP Access Controllers manuals by other brands

ZKTeco KF1000 Series user manual

ZKTeco

ZKTeco KF1000 Series user manual

Cobra Controls ACP Series quick start guide

Cobra Controls

Cobra Controls ACP Series quick start guide

Velleman HAA2801 Programming & installation manual

Velleman

Velleman HAA2801 Programming & installation manual

H3C WX1800H series Command reference

H3C

H3C WX1800H series Command reference

Cisco Physical Access 1125 manual

Cisco

Cisco Physical Access 1125 manual

TransTel Communications IP3922 Series user manual

TransTel Communications

TransTel Communications IP3922 Series user manual

FingerTec R2 user guide

FingerTec

FingerTec R2 user guide

FEITIAN AllinPass FIDO2 K33 user manual

FEITIAN

FEITIAN AllinPass FIDO2 K33 user manual

Alula RE6100P Series instructions

Alula

Alula RE6100P Series instructions

Soyal AR-101-H Installation

Soyal

Soyal AR-101-H Installation

ATEN CS231 user manual

ATEN

ATEN CS231 user manual

KEYKING FPC1000 Series user manual

KEYKING

KEYKING FPC1000 Series user manual

CVT Face A+ user guide

CVT

CVT Face A+ user guide

Progeny P3.GPRS V4 manual

Progeny

Progeny P3.GPRS V4 manual

Rosslare AYC-W6500 Installation and operation manual

Rosslare

Rosslare AYC-W6500 Installation and operation manual

Supra TRACcess BT Smart Device manual

Supra

Supra TRACcess BT Smart Device manual

Genie GDG360BT user manual

Genie

Genie GDG360BT user manual

SENS-O-LOCK WC9000+ user guide

SENS-O-LOCK

SENS-O-LOCK WC9000+ user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.