Aristel AV-96 User guide

System Installation Manual
CONTENT
96
AV
1
GENERAL DESCRIPTION.........................................................................................................1
2
SYSTEM’S SPECIFICATION .....................................................................................................2
2.1
B
ASIC
S
PECIFICATION
...........................................................................................................2
2.2
S
YSTEM
’
S
G
ENERAL
S
PECIFICATION
.......................................................................................2
2.3
E
LECTRICAL
&
O
THER
S
PECIFICATIONS
..................................................................................3
2.4
S
YSTEM
M
ODULES
...............................................................................................................4
2.5
S
YSTEM
C
APACITY
C
ONFIGURATIONS
.....................................................................................5
3
PREPARATION & NOTE FOR THE SYSTEM’S INSTALLATION...............................................6
3.1
P
REPARATION FOR
S
YSTEM
I
NSTALLATION
...............................................................................6
3.2
S
PECIAL
R
EQUIREMENTS FOR
I
NSTALLATION
E
NVIRONMENT
......................................................6
3.3
E
QUIPMENT
R
EMARKS
..........................................................................................................6
4
AV-96 PCB & CABINET LAYOUT ..............................................................................................7
4.1
AV-96
T
HREE
-
DIMENSIONAL
V
IEW
L
AYOUT
..............................................................................7
4.2
AV-96
B
UILT
-
IN
S
TANDARD
R
ACK
L
AYOUT
...............................................................................8
4.3
AV-96
I
NTER
-C
IRCUIT
L
AYOUT
...............................................................................................9
4.4
AV-96
S
YSTEM
W
ALL
M
OUNTING
I
NSTALLATION
.....................................................................10
4.5
AV-96
M
OTHER
B
OARD
U
NIT
(A9MBUA) ............................................................................. 11
4.6
AV-96
P
OWER
U
NIT
(A9PWUA)..........................................................................................12
4.7
AV-96
M
AIN
P
ROCESSING
U
NIT
(A9MPUA)..........................................................................13
4.8
AV-96
T
RUNK
U
NIT
(A9TKUA)............................................................................................14
4.9
AV-96
C
ALLER
ID
C
ARD
(D1CIDC) .....................................................................................15
4.10
AV-96
K
EY
P
HONE
S
TATION
U
NIT
(A9STUA)........................................................................16
4.11
AV-96
SLT
S
TATION
U
NIT
(A9SLUA) ...................................................................................17
4.12
AV-96
H
YBRID
S
TATION
U
NIT
(A9HYUA)..............................................................................18
4.13
AV-96
V
OICE
S
ERVICE
C
ARD
(A9VSCA)..............................................................................19
4.14
AV-96
R
EMOTE
P
ROGRAMMING
C
ARD
(A6RPCA).................................................................20
4.15
AV-96
M
ULTI
-
FUNCTION
C
ARD
(A6MFCA)............................................................................21
5
AV-96 SYSTEM WIRING & INSTALLATION.............................................................................22
5.1
AV-96
P
OWER
I
NSTALLATION
AC/DC.................................................................................22
5.2
AV-96
S
YSTEM
B
ACK
-
UP
B
ATTERY
I
NSTALLATION
..................................................................23
5.3
AV-96
CO
L
INE
W
IRING
......................................................................................................24
5.4
AV-96
P
OWER
F
AILURE
T
RANSFER
(PFT)
P
HONE
W
IRING
.............................................................25
5.4
AV-96
K
EY
P
HONE
S
TATION
W
IRING
....................................................................................26
5.5
AV-96
S
INGLE
L
INE
S
TATION
W
IRING
....................................................................................27
5.6
AV-96
D
OOR
P
HONE
I
NSTALLATION
......................................................................................28
5.7
AV-96
M
ULTI
-
FUNCTION
S
ENSOR
I
NSTALLATION
.....................................................................29

System Installation Manual
CONTENT
96
AV
5.8
AV-96
M
ULTI
-
FUNCTION
R
ELAY
—D
OOR
S
WITCH
I
NSTALLATION
...............................................30
5.9
AV-96
E
XTERNAL
M
USIC
S
OURCE
I
NSTALLATION
...................................................................31
5.10
AV-96
E
XTERNAL
P
AGING
I
NSTALLATION
...............................................................................32
5.11
AV-96
RS232
(SMDR)
I
NSTALLATION
..................................................................................33

System Installation Manual
1
96
AV
1 General Description
Thanks for choosing our AV-96 key telephone system.
AV-96 possesses the most advanced technology with 12 free I/O interface slots,
provides maximum 96 ports. Trunk Unit each has 4 CO ports, while Station Unit each
has 8 extension ports. Also every system can be installed with one piece of hybrid
station unit, whose all 8 ports were designed as hybrid ports and can be connected
directly with the key phone or SLT. According to customers’ requirements, you can
choose KP station unit, SLT unit or hybrid unit optionally. The Caller ID function is
supported not only to the key phone but also the SLT for all incoming calls and the
transferred calls.
AV-96 is equipped with many peripherals, such as RS-232 for data output, door phone,
multi-function sensor, multi-function relay, remote programming maintenance,
external music source, external paging, voice auto-attendant and so forth. We are
proud to say, this system is a break-through product among the key telephone
systems.
AV-96 KTS is of a cards insertion designs. The ports of Mother Board, Power Unit,
Trunk/station Unit and peripherals act independently. All system’s ports use RJ45
Module Connector Wiring disregarding the traditional wiring method. This change
makes the construction more efficiently and reliably. All functions of this system can
be programmed to realize “One-Touch” action.
This installation manual presents the detailed descriptions of all the steps of
installation and the notices. We hope to assist you to complete the system installation
successfully and obtain the telecommunication service, efficient management to the
utmost extent.
If there is any query in this field, please feel free to contact the nearest authorized
agent for assistance.

System Installation Manual
2
96
AV
2 System’s Specification
2.1 Basic Specification
System Capacity96 free ports
CO lines: 0~20
Station lines: 0~96
System dimensions440mm × 305.6mm × 202mm
System ControlStored Program Control
Switch ControlSpace Division Matrix
Maximum Power Consumption170W
Working Temperature0~45
Working Humidity10~90 non-condensing
2.2 System’s General Specification
The trunk cards and station units should be installed at any 12 free I/O interface slots.
All the peripherals cards should be installed at the specified sockets.
AV-96 Basic Capacity Expansion
Capacity
Maximum
Capacity
Co Line 0 4 20
Key Phone 0 8 / 0 96 / 0
Extension
SLT 0 0 / 8 0 / 96
Door Phone 0 2 2
Relay Switch 0 2 2
Sensor Interface 0 2 2
Auto-Attendant 0 1 / 2 2 / 4
RS232 for SMDR 1 0 1
UPS Interface 1 0 1
Speed Dial 1000 0 1000
Power Failure Transfer Phone
(PFT) 0 4 20
Table 1 System’s General Specification

System Installation Manual
3
96
AV
2.3
Electrical & Other Specifications
AV-series AV-96
Input AC Voltage AC10024050/60hz
System 170W
Key Telephone 1~2W
SLT 0.85W
Power
Consumption
Door Phone 0.5W
System Power Back-up Battery 7AH 1~2 hours
Outgoing Dialing Tone / Pulse
Dialing Signal Intercom Dialing Tone / Pulse / Digital
Co Line Maximum1.5K
Key Telephone Maximum40
SLT Maximum400
Door Phone Maximum40
Loop Resistance
External Paging Maximum800
Co Line 2-conductor wiring
Key Phone 4-conductor wiring
SLT 2-conductor wiring
Door Phone 2-conductor wiring
External Paging 2-conductor wiring
External Music Source 2-conductor wiring
Relay 2-conductor wiring
Sensor 2-conductor wiring
Fax 2-conductor wiring
Wiring Installation
SMDR D-TYPE 9 pins
Type SPDT (just 1 set is enough)
Power Capacity Maximum 120V7A
Relay
Function
Supported by system software: Door Switch,
External Paging, Account Code, Adjustable
Ringing Volume…
System Dimension (mm) 440mm305.6mm202mm
Key Phone Dimension (mm) 200 * 180 * 75mm
Working Temperature 0~ 45
Working Humidity 10~90non-condensing
Switch Mode SDMSpace Division Matrix
Control Mode Stored Program Control (SPC)
Table 2 Electric standard for System
Subject to the changes without notice.
The correct specification to be mentioned on the quotation or contract.

System Installation Manual
4
96
AV
2.4 System Modules
Model No.
Description Remark
A9-96A MAIN EQUIPMENT, consisting of (A9CBMA + A9MPUA) Standard Shipment
A9CBMA MAIN CABINET, consisting of (Plastic Cabinet + A9MBUA +
A9PWUA) Spare Part
A9PWUA SWITCHING POWER SUPPLY UNIT Spare Part
A9MBUA MOTHER BOARD UNIT, consisting of 12 I/O slots. Spare Part
A9MPUA MAIN PROCESSING UNIT, consisting of RS-232 interface Spare Part
A9TKUA TRUNK UNIT, consisting of 4 CO Line Ports, with Lightening
Protection Expansion Card
D1CIDC FSK/DTMF CLI INTERFACE,
one Channel of POTS Caller
Number Identification card. Optional Card
A9STUA KEY STATION UNIT, consisting of 8 Key Station Ports Expansion Card
A9HYUA HYBRID STATION UNIT, consisting of 8 Fully Hybrid Station
Ports (maximum one card in the system) Expansion Card
A9SLUA SINGLE LINE STATION UNIT, consisting of 8 Single Line
Station Ports Expansion Card
A9VSCA VOICE SERVICE CARD, consisting of 2 Voice Channels (60
seconds per channel) Optional Card
A6MFCA MULTI FUNCTION CARD, consisting of (2 Sensors + 2 Relays
+
2 Door Phone Interfaces) Optional Card
A6MDCA METERING DETECTION CARD (for both 12KHz and 16KHz
Metering Pulse) Optional Card
A6RPCA REMOTE PROGRAMMING CARD (standard Modem design) Optional Card
Table 3 System’s Accessories
Subject to the changes without notice.
The correct specification to be mentioned on the quotation or contract.

System Installation Manual
5
96
AV
2.5 System Capacity Configurations
System
capacity
Station Unit Quantity
(Key Phone /SLT/Hybrid Station Unit; but only one pieces of Hybrid Station can be installed.)
Trunk Unit Qty
1 2 3 4 5 6 7 8 9 10 11 12
0 008
016
024
032
040
048
056
064
072
080
088
096
1 408 416 424 432
440
448
456
464
472
480
488
2 808 816 824 832
840
848
856
864
872 880
3 1208
1216
1224
1232
1240
1248
1256
1264
1272
4 1608
1616
1624
1632
1640
1648
1656
1664
5 2008
2016
2024
2032
2040
2048
2056
Table 4 System Capacity Configurations
This system provides12 free I/O interface slots. Any Trunk Units or Station Units can be
installed to these 12 slots according to user’s requirements.
Three different Station Units (Key phone station unit, SLT station unit or Hybrid station unit)
are at user’s option. But only one pieces of Hybrid station unit can be installed.

System Installation Manual
6
96
AV
3 Preparation & Note for the System’s Installation
3.1 Preparation for System Installation
Please check whether the system capacity and the quantity of phones are suitable
or not.
Please prepare the necessary wires and instruments for installation.
Please carefully read this manual before installation and follow up the procedures
of installation on this manual.
3.2 Special Requirements for Installation Environment
Input AC Voltage: Universal AC100 ~ 240V
Back-up Battery: Built-in charger included. Connect directly to DC24V battery for
power-off.
Wiring Requirements
CO Line: 2-conductor wiring
Key Phone: 4-conductor wiring
SLT2-conductor wiring
Door Phone: 2-conductor wiring
Relay / Sensor: 2-conductor wiring
External Music Source / External Paging: 2-conductor wiring
3.3 Equipment Remarks
The system should be installed at a clean, dry and secure position, 10 centimeters
above the ground to avoid the vibration.
The location must have adequate ventilation and a temperature range between 0 ~
45
o
C with a 10 ~ 90% non-condensing relative humidity.
The installation site should have sufficient room to mount the KSU along with the
necessary connecting blocks and ancillary equipment. The installation site should
not be at the area with static electricity (e.g. Dry copiers), or vibration (e.g. Heavy
duty machinery).
This system must use the independent power input. The power should better not
share with other power-consumption equipment, for example: huge power
consumption machine and be controlled directly by main switch. In addition, the
location must be far away from high frequency & noise soundings to avoid the
interference from radiation EMI.
The power must use three-way socket (with grounding connector).
Voltage Stabilizer is recommended if the electricity supply is not so stable.
Please use the lightning-protection equipment to guarantee system’s stability.
Suggest using twist wires for CO line & station line to avoid noise and interruption.
SLT wiring must be away from some other disturbance (e.g.radio wave).
Otherwise a separate earth is required in addition to the third earth wire on the AC
circuit.

System Installation Manual
7
96
AV
4 AV-96 PCB & Cabinet Layout
4.1 AV-96 Three-dimensional View Layout
Chart 1
AV-96 Three-dimensional View Layout
System dimensionsmm: 440mm305.6mm202mm
System Wiring Outlet
AC Power Connector
Battery Connector Fuse Socket
DC Power Switch
AC
AC
AC
AC Power Switch
Side Cover
Radiator Hole
Fan Installation Hole
Main Cover
Screw Socket
Main Cover
Radiator Hole
Cabinet Handhold
Installation Socket
96

System Installation Manual
8
96
AV
4.2 AV-96 Built-in Standard Rack Layout
Chart 2
AV-96 built-in Standard Rack Layout
Fixed to Rack
Hole
CO/Station Line Port
Cabinet
Handhold
RS232 Port
Wire harness
Hole
External music/Paging
Interface
Peripherals
Wiring Outlet

System Installation Manual
9
96
AV
Fan
LABEL
LABEL
Main Processing
Unit (A9MPUA)
12 free I/O interface slots for A9TKUA,
A9STUA, A2SLUA or A9HYUA
Voice Service Card
(A9VSCA)
Power Unit (A9PWUA)
Grounding
Connector
Multi-function
Card (A6MFCA)
Remote Programming
Card (A6RPCA)
4.3 AV-96 Inter-Circuit Layout
Chart 3
AV-96 Inter-circuit Layout
AV-96 Maximum Capacity: 96 Ports/12 free I/O interface slots
CO Line Max. Capacity: 20 Ports
Station Line Max. Capacity: 96 Ports (Key phone, SLT Station or Hybrid Station unit. But only
one pieces of Hybrid station unit can be installed in one system)
Auto Attendant, Maximum 4 channels (60 seconds)
Note: Please fasten the snap-close after fitting well all I/O Units in the correct slots.

System Installation Manual
10
96
AV
Wall Mounting
Method
Hanging measure scale
Side Cover
inside View
4.4 AV-96 System Wall Mounting Installation
Chart 4
AV-96 System Wall Mounting Installation
System Suggested to be installed 10cm or more above ground, avoiding humidity.
There are the two-way hanging measure scales on the inside-surface of System Side Cover,
which is convenient for customer’s installation.

System Installation Manual
11
96
AV
4.5 AV-96 Mother Board Unit (A9MBUA)
Chart 5
AV-96 Mother Board Unit
A9MBUA
A9MPUA and A9PWUA should be installed at the specified slots.
The Station cards (A9STUA, A9HYUA or A9SLUA) can be installed at any 12 free I/O
interface slots on A9MBUA. IO1~IO12: 12 free I/O interface slots for A9TKUA, A9STUA,
A2SLUA or A9HYUA. Only one piece of A9HYUA can be used.
Four peripheral cards (2 A6VSCA, 1 A6RPCA and 1 A6MFCA) should be installed at the
designed slots.
A9MBUA is directly mounted on the System’s Plastic cabinet.
VSC
MFC RPC
VSC
Grounding
Connector
12 free I/O interface slots for A9TKUA,
A9STUA, A2SLUA or A9HYUA
Power Unit Slot
1
2
3
4
5
6
7
8
9
10
11
12
Multi-function
Card Socket
Main Processing
Unit Slot
Voice Service
Card Socket 2
Remote Programming
Card Socket
Voice Service
Card Socket 1

System Installation Manual
12
96
AV
4.6 AV-96 Power Unit (A9PWUA)
Chart 6
AV-96 Power Unit
A9PWUA
This switching power provides Power Factor Correction (PFC).
A9PWUA is a Full-Range Power Unit with AC100V~240V.
AC Power
Switch
Power Fuse
5A /250V
Fan Power
Connector
Back-up
Battery
Connector
AC Power
Connector
Power Unit Output
Pin designation

System Installation Manual
13
96
AV
CO Line
Expansion
Jumper
External
Music/Paging
Port
RS232 Connector
Aristel
Main Program IC
CPU
Program protection
Battery
4.7 AV-96 Main Processing Unit (A9MPUA)
Chart 7
AV-96 Main Processing Unit (A9MPUA)
A9MPUA should be inserted in the specified Slot on A9MBUA.
System Main Program IC is inserted on A9MPUA.
There are standard RS232, external music source and external paging ports on A9MPUA.
When adding Trunk Units to the system, the CO Line Expansion Jumper on A9MPUA should
be corresponding with the Jumper to select Trunk Unit Position on A9TKUASee Table 6.
CO Line Expansion Jumper (0: OFF1: ON)
Trunk Unit Slot
TK1 TK2 TK3 TK4 TK5
1
12
123
1234
12345
Table 5
CO Line Expansion Jumper on A9MPUA

System Installation Manual
14
96
AV
CO Line Port
The Jumper to Select the Position
of A9TKUA in the System
Caller ID
Card Socket
Pulse exploration
Card Socket
Power-failure
SLT Port
4.8 AV-96 Trunk Unit (A9TKUA)
Chart 8
AV-96 Trunk Unit (A9TKUA)
A9TKUA should be installed at any free slot from IO1 to IO5 on A9MBUA in sequence.
The jumper to select the position of A9TKUA in the system should be corresponding with the
CO Line Expansion Jumper (See Table 5) on A9MPUA.
The Jumper to select Trunk Unit Position (0: OFF1: ON)
Trunk Unit Position
TK1 TK2 TK3 TK4 TK5
I01 1111 0000 0000 0000 0000
I02 0000 1111 0000 0000 0000
I03 0000 0000 1111 0000 0000
I04 0000 0000 0000 1111 0000
I05 0000 0000 0000 0000 1111
Table 6
Trunk Unit Position Selection Jumper on A9TKUA

System Installation Manual
15
96
AV
Socket
4.9 AV-96 Caller ID Card (D1CIDC)
Chart 9
AV-96 Caller ID Card (A9CIDC)
Each DICIDC can be added to one A9TKUA CO Line.
Caller ID function as well as incoming call forward can be supported not only key phone but
also SLT (with DTMF signal) phone.

System Installation Manual
16
96
AV
Key Phone
Station Line Port
4.10 AV-96 Key Phone Station Unit (A9STUA)
Chart 10
AV-96 Key Phone Station Unit (A9STUA)
A9STUA can be installed at any free slots from IO1 to IO12 on A9MBUA.
Each A9STUA contains 8 Key Phone station ports.
All the station ports have short-circuit protector.

System Installation Manual
17
96
AV
SLT Station
Line Port
4.11 AV-96 SLT Station Unit (A9SLUA)
Chart 11
AV-96 SLT Station Unit (A9SLUA)
A9SLUA can be installed at any free slot from IO1 to IO12 on A9MBUA.
Each A9SLUA contains 8 Standard SLT station ports.
All the station ports have short-circuit protector.

System Installation Manual
18
96
AV
Hybrid Station
Line Port
4.12 AV-96 Hybrid Station Unit (A9HYUA)
Chart12
AV-96 Hybrid Station Unit (A9HYUA)
A9HYUA can be installed at any free slot from IO1 to IO12 on A8MBUA.
Each A9HYUA contains 8 station line ports, which was designed as hybrid ports for key
phone or SLT.
All the station ports have short-circuit protector.
Table of contents
Other Aristel Telephone manuals

Aristel
Aristel AN208 User manual

Aristel
Aristel Genius X2 User manual

Aristel
Aristel AV SERIES User manual

Aristel
Aristel AV SERIES User manual

Aristel
Aristel DV-38 User manual

Aristel
Aristel DV-38 User guide

Aristel
Aristel 50 Series User manual

Aristel
Aristel AV 32A User manual

Aristel
Aristel KP-30 User manual

Aristel
Aristel AV-8 User manual