EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Arjo
  6. •
  7. Medical Equipment
  8. •
  9. Arjo Sapphire Comfort Turn User manual

Arjo Sapphire Comfort Turn User manual

Other Arjo Medical Equipment manuals

Arjo Huntleigh WoundExpress User manual

Arjo

Arjo Huntleigh WoundExpress User manual

Arjo Lifeguard LG20 User manual

Arjo

Arjo Lifeguard LG20 User manual

Arjo MAA8000 User manual

Arjo

Arjo MAA8000 User manual

Arjo Enterprise 9000X User manual

Arjo

Arjo Enterprise 9000X User manual

Arjo Stretcher Slings User manual

Arjo

Arjo Stretcher Slings User manual

Arjo MAA4020M User manual

Arjo

Arjo MAA4020M User manual

Arjo Maxi Sky 2 PLUS User manual

Arjo

Arjo Maxi Sky 2 PLUS User manual

Arjo Prioma Couch Electric User manual

Arjo

Arjo Prioma Couch Electric User manual

Arjo HUNTLEIGH Sonicaid Team3 User manual

Arjo

Arjo HUNTLEIGH Sonicaid Team3 User manual

Arjo TORNADO FD1800 User manual

Arjo

Arjo TORNADO FD1800 User manual

Arjo Maxi Sky 600 ECS User manual

Arjo

Arjo Maxi Sky 600 ECS User manual

Arjo Flowtron Excel User manual

Arjo

Arjo Flowtron Excel User manual

Arjo Sara Combilizer User manual

Arjo

Arjo Sara Combilizer User manual

Arjo Maxi Sky 2 User manual

Arjo

Arjo Maxi Sky 2 User manual

Arjo Walker Manual

Arjo

Arjo Walker Manual

Arjo FIRST STEP User manual

Arjo

Arjo FIRST STEP User manual

Arjo HUNTLEIGH Hydroven 1 User manual

Arjo

Arjo HUNTLEIGH Hydroven 1 User manual

Arjo Alpha Active 4 User manual

Arjo

Arjo Alpha Active 4 User manual

Arjo Enterprise ENT-ACC32 User manual

Arjo

Arjo Enterprise ENT-ACC32 User manual

Arjo TheraKair Visio User manual

Arjo

Arjo TheraKair Visio User manual

Arjo Auralis User manual

Arjo

Arjo Auralis User manual

Arjo Maxi Sky 1000 User manual

Arjo

Arjo Maxi Sky 1000 User manual

Arjo LGMAT/13 User manual

Arjo

Arjo LGMAT/13 User manual

Arjo Alpha Active 5 User manual

Arjo

Arjo Alpha Active 5 User manual

Popular Medical Equipment manuals by other brands

TekTone Tek-CARE160 Installation and operation manual

TekTone

TekTone Tek-CARE160 Installation and operation manual

NeuroMetrix Quell 2.0 user manual

NeuroMetrix

NeuroMetrix Quell 2.0 user manual

AMT XLR8 Quick reference guide

AMT

AMT XLR8 Quick reference guide

EDAN SONOTRAX Pro user manual

EDAN

EDAN SONOTRAX Pro user manual

Restorative Therapies RT300 Service guide

Restorative Therapies

Restorative Therapies RT300 Service guide

Gendex Expert DC installation manual

Gendex

Gendex Expert DC installation manual

Dexcowin ADX4000W user manual

Dexcowin

Dexcowin ADX4000W user manual

Libelium MySignals user manual

Libelium

Libelium MySignals user manual

Acelity V.A.C.ULTA 4 user manual

Acelity

Acelity V.A.C.ULTA 4 user manual

Caputron ActivaDose II tDCS quick start guide

Caputron

Caputron ActivaDose II tDCS quick start guide

Plinth 2000 93CDT Service manual

Plinth 2000

Plinth 2000 93CDT Service manual

GE SENOGRAPHE 800T Operator's manual

GE

GE SENOGRAPHE 800T Operator's manual

GE Definium 5000 Operator's manual

GE

GE Definium 5000 Operator's manual

Kanmed GE-1380 user manual

Kanmed

Kanmed GE-1380 user manual

Huntleigh FD1 Instructions for use

Huntleigh

Huntleigh FD1 Instructions for use

Stryker SPR Plus Operation manual

Stryker

Stryker SPR Plus Operation manual

Tobii Dynavox I-Series user manual

Tobii Dynavox

Tobii Dynavox I-Series user manual

S-Capepod Evac Cocoon Step-by-step guide

S-Capepod

S-Capepod Evac Cocoon Step-by-step guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

TURN ASSIST LOW AIR LOSS MATTRESS REPLACEMENT SYSTEM
Sapphire Comfort Turn
The Sapphire Comfort Turn® mattress replacement system is a therapeutic
mattress that provides either active or reactive pressure redistribution and low air
loss therapy.
When mobility, moisture and/or inactivity are healthcare concerns, it is indicated
for the prevention and treatment of pressure ulcers and other skin related injuries.
Features include:
• Static Mode with adjustable comfort level setting
• Soft – decreases airflow for a softer setting
• Fowler mode which is used when head section of the bed is elevated and increases airflow to the mattress for seat
inflation
• Pulsate mode with cycle time options (3-20 minutes) and adjustable comfort level setting
• Turning mode options of Right Turn, Left Turn or Full Turn - approximately 40° rotation
• In full turn mode the control unit has a preset of 3-minute intervals, these may be adjusted from 3 to 20 minutes, 30,
45, 60, 75 or 90 minutes
• Autofirm – quickly inflates mattress to maximum firmness
• Lockout – locks all functions automatically after 3 mins. To disable, press and hold lockout button for 3 seconds
• Quick Deflation or CPR Use
• Low Pressure – light will indicate when pressure is getting too low
• Power Failure – light will indicate when power is no longer being provided to unit
• Alarm Silence – mutes the audible alarm. (Visual light will not turn off until failure is resolved)
• Weight capacity in static/pulse mode up to 453.59kg
• Weight capacity in turning mode up to 204.11kg
AMF-33
DISTRIBUTED BY MANUFACTURED BY
The following Product Specification is intended to assist the user in understanding the basic functions of the product.
This information does not replace the safety warnings, cautions and other important information provided in the
Instructions for Use (IFU) supplied with the equipment; copies of the IFU are available electronically on request from Arjo.
Refer to the product instructions for use before using the product.
This chart is to be used as a reference ONLY. Final patient settings must be completed by the
patient’s caregiver.
Cycle Time
Increases or decreases the
time of cycle between 3 to
90 minutes.
Alarm Silence
Mutes the audible alarm.
(Visual light will not turn
off until failure is resolved.)
Soft
Decreases airflow for a
softer setting.
Fowler
Used when head section of
bed is elevated. Increases
airflow to the mattress.
Mode
Press the Mode button to
select Right Turn, Left Turn
or Full Turn.
Autofirm
Quickly inflates mattress to
maximum firmness.
Lockout
Locks all functions
automatically after 3 mins.
To disable, press and hold
lockout button for 3 sec.
Firm
Increases airflow for a
firmer setting.
Power Failure
Light will indicate when power is no
longer being provided to unit.
Low Pressure
Light will indicate when pressure is
getting too low.
Pulsate
Press to begin
Pulsation therapy
KEYPAD QUICK REFERENCE GUIDE
Sapphire Comfort Turn
AMF-33
Reference: Doc. #8092, Rev. 2.0, Rev. ECO 053118-1, Date: 06/04/2018
DISTRIBUTED BY MANUFACTURED BY
This Quick Reference Guide (QRG) is intended to assist the user in understanding the basic functions of this product.
The QRG does not replace the safety warnings, cautions and other important information provided in the Instructions for
Use (IFU) supplied with the equipment; copies of the IFU are available on request from Arjo.
Refer to the product instructions for use before using this product.