Atop MB5201 Series Manual

Industrial Serial Device Sever
Industrial Modbus Gateway
SE5201 / MB5201 / SE5201C / MB5201C Series
Version 1.1
Updated in January, 2019
P/N : 89900532G
Tel: 886-3-5508137
Fax: 886-3-5508131
www.atop.com.tw
Inside the package you will find the following items:
■ Industrial Serial Device Sever x 1
■ 3-Pin Terminal Block x 1 or 5-Pin Terminal Block x 1 (Depend on model)
■ Wall mount screws x 2
■ Installation Guide with Warranty Card x 1
Front View
3. DC Jack Power Input
4. Terminal Block Power Input
(SE5201/MB5201 series only)
5. Reset
6. 10/100M LAN port
7. RUN LED
8. LAN LED
9. COM LED
1. COM Port - Terminal Block 2. COM Port -DB9
Top View
RUN LAN COM
7 8 9
Back View
V- V+FG
3 4 65
1 2
You can then choose whether to plug in
the other peripheral ports at this point
or do it later depending on the actual
location of the device or level of
comfort for performing such operation.
3.
Once the plate has been firmly put in
place, proceed to mount the whole
device as shown in (Fig. 3).Proceed to
(Fig. 4) if you want to remove the
device from DIN-Rail.
4.
Next we can then proceed to connect
the device to the LAN (switch or PC,
depending on the case), take care on
using the RJ-45 connector; after this
we can then proceed to the device’s
settings
5.
If you have purchased the wall mount
kit, proceed to place the screws on the
back of the device as show in (Fig. 1).
1.
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect
your device, it is still strongly advised
to ground the device properly; hazard-
ous ESD can come into contact and
damage your equipment. On the power
terminal block, there is a terminal for
Frame Ground, you can choose
whether to connect it to the grounding
or you may opt to connect to the
grounding screw next to the terminal
block ( the one chosen should be
connected at all times ) (Fig. 2)
■ The Serial Sever’s factory IP by default
is 10.0.50.100 Web UI once it is
connected to a physical network (or
using Management Utility, for more
information on Management Utility,
please refer to its manual). Please be
aware that the PC needed for this
procedure needs to be in the same
subnet, or you may refer yourself to
the device User’s Manual.
■ The opening to the sides are for the device’s heat dissipation please never
obstruct or cover them with any objects or try to insert them through it.
FG V- V+
FG V- V+
1
2
1
2
Color State
LED Description
LAN
RUN
COM
Orange
Green
Green
Green
Blinking
Blinking
Off
Blinking
Off
Transmission is active (100Mbps)
No transmission is made
COM is transmitting/receiving
COM is not transmitting/receiving
Transmission is active (10Mbps)
On
System is booted up and not running AP
Blinking
System is booted up and running
Off
System is still booting up or powered off
Off
No transmission is made
Power Input of Terminal Block : 9-30V DC; 0.2A max.
(SE5201/MB5201 series only)
Power Input of DC Jack : 5V with power adapter only
DB9
Pin
1
2
3
4
5
6
7
8
9
Pin
1
2
3
4
5
RS-232
DCD
RxD
TxD
DTR
SG
DSR
RTS
CTS
RI
RS-232
RxD
CTS
TxD
RTS
SG
RS-422 and 4-wire RS-485
-
TxD+
RxD+
-
SG
-
RxD-
TxD-
-
RS-422 / 4-W RS-485
TxD+
TxD-
RxD+
RxD-
SG
RS-485 (2W)
-
Data+
-
-
SG
-
-
Data-
-
2-W RS-485
Data+
Data-
-
-
-
Terminal Block
Terminal Block for Power input (SE5201/MB5201 series only)
Pin / Signal
FG V- V+
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only
harm the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on section
of your User’s Manual.
Field Maintenance and Service
40 25 10
65.3
76.3
88.5
39.15
78.3
27.8
Front View
Back View
27.8
SE5201 / MB5201SE5201C / MB5201C
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
shall be replaced with a new one within 3 months after purchase. The shipping
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Atop shall not be held responsible for any consequential losses from using Atop’s
product.
Warranty Policy
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty Conditions
RMA and Shipping Costs Reimbursement
Limited Liability
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:[email protected]
Web Site:www.atop.com.cn, e-mail:[email protected]
Atop Customer Services and Supports
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Warranty Period
─ Any changes to this material will be announced on Atop website. ─

This manual suits for next models

3

Other Atop Gateway manuals

Atop MB5404D Series User manual

Atop

Atop MB5404D Series User manual

Atop CR5201B Series User manual

Atop

Atop CR5201B Series User manual

Atop PG5901B Series Instruction sheet

Atop

Atop PG5901B Series Instruction sheet

Atop PG5901B Series Instruction sheet

Atop

Atop PG5901B Series Instruction sheet

Atop MB5400 User manual

Atop

Atop MB5400 User manual

Atop MB5001C User manual

Atop

Atop MB5001C User manual

Atop MB5904D User manual

Atop

Atop MB5904D User manual

Atop PG59 Series User manual

Atop

Atop PG59 Series User manual

Atop MB5001C User manual

Atop

Atop MB5001C User manual

Atop MB52 Series User manual

Atop

Atop MB52 Series User manual

Atop SE5901 Series Manual

Atop

Atop SE5901 Series Manual

Atop MB5404D-X Series Manual

Atop

Atop MB5404D-X Series Manual

Popular Gateway manuals by other brands

AT&T MicroCell user guide

AT&T

AT&T MicroCell user guide

Climax Vesta ESGW Series installation guide

Climax

Climax Vesta ESGW Series installation guide

Comtrend Corporation WR-6891u user manual

Comtrend Corporation

Comtrend Corporation WR-6891u user manual

LevelOne AMG-2100 user manual

LevelOne

LevelOne AMG-2100 user manual

Crest Audio NDP-ENG ETHERNET NEXSYS GATEWAY Specifications

Crest Audio

Crest Audio NDP-ENG ETHERNET NEXSYS GATEWAY Specifications

Gemtek GIoT Femto WLRGFM-100 user guide

Gemtek

Gemtek GIoT Femto WLRGFM-100 user guide

Yeastar Technology NeoGate TG200 user manual

Yeastar Technology

Yeastar Technology NeoGate TG200 user manual

Teltonika RUT950 manual

Teltonika

Teltonika RUT950 manual

Mennekes eMobility-Gateway Professional+ OPERATING AND INSTALLATION Manual

Mennekes

Mennekes eMobility-Gateway Professional+ OPERATING AND INSTALLATION Manual

HMS HMS-EN2MB-R user manual

HMS

HMS HMS-EN2MB-R user manual

Encom Harmony IP I/O8 user manual

Encom

Encom Harmony IP I/O8 user manual

AudioCodes Mediant 1000B Hardware installation manual

AudioCodes

AudioCodes Mediant 1000B Hardware installation manual

Sixnet EtherTRAK ET-GT-ST-3 user manual

Sixnet

Sixnet EtherTRAK ET-GT-ST-3 user manual

COX Technicolor CGM4331 Getting started

COX

COX Technicolor CGM4331 Getting started

RTA 460ETCPS-N700 Product user guide

RTA

RTA 460ETCPS-N700 Product user guide

WePresent WiPG-1600 quick start guide

WePresent

WePresent WiPG-1600 quick start guide

Pepperl+Fuchs VBG-PN-K20-D-BV Installation instruction

Pepperl+Fuchs

Pepperl+Fuchs VBG-PN-K20-D-BV Installation instruction

RTA 460TCP-N2E Product user guide

RTA

RTA 460TCP-N2E Product user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.