Installation
1. Turn off the PC and DVI monitor.
2. Connect the DVI extension cable between the PC and
the “DVI IN” port of DVI-ELW.
3. Connect the DVI extension cable between the DVI
monitor and the “DVI OUT” port of DVI-ERW.
4. Connect the CAT.5 cables between the DVI-ELW “LINK”
port and the DVI-ERW “LINK” port of extender.
5. Connect the power cord and turn on the extender.
6. Turn on the PC and DVI monitor.
IR Receiver Cable Directions:
Put it into the DVI-ERW “IR2 IN” port and place the IR
Receiver Cable, so that you can point to it easily with your
IR remote controller.
IR Blaster Cable Directions:
Plug IR blaster cable plug into DVI-ELW “IR OUT” port, it
sits in front of the device receiver’s IR sensor, which is
located on the front-panel.
Additional Options
Select any additional options you may require.
1. IR Receiver Cable
GND
+V
Sig
2. IR Blaster Cable
NC
P+
N-
-3-
Technical Specifications Output Signal
1 T.M.D.S Data 2- 16 Hot Plug Detect
2 T.M.D.S Data 2+ 17 T.M.D.S Data 0-
3 T.M.D.S Data 2/4 Shield
18 T.M.D.S Data 0+
4 T.M.D.S Data 4- 19 T.M.D.S Data 0/5 Shield
5 T.M.D.S Data 4+ 20 T.M.D.S Data 5-
6 DDC Clock 21 T.M.D.S Data 5+
7 DDC Data 22 T.M.D.S Clock Shield
8 Analog Vert. Sync 23 T.M.D.S Clock+
9 T.M.D.S Data 1- 24 T.M.D.S Clock-
10 T.M.D.S Data 1+
11 T.M.D.S Data 1/3 Shield
C1 Analog Red
12 T.M.D.S Data 3- C2 Analog Green
13 T.M.D.S Data 3+ C3 Analog Blue
14 +5V Power C4 Analog Horz Sync
15 GND C5 Analog Ground
Wiring Information & Coding
Identification
Assignment
Conductor
Pair 1 5 White-Blue
4 Blue
Pair 2 1 White-Orange
2 Orange
Pair 3 3 White-Green
6 Green
Pair 4 7 White-Brown
8 Brown
-4-