Bartec SILASPZ User manual

Manual Ex p Control Unit
SILASpz

BARTEC GmbH
Max-Eyth-Straße 16
97980 Bad Mergentheim
GERMANY
Phone: +49 7931 597-0
Fax: +49 7931 597-480
Internet: www.bartec.de
Operating Instructions
Ex p Control unit
SILASpz, Type A7-37S2-2111/*520
Stainless steel version
ATEX / IECEx Zone 2 / 22
Document number: A1-37S2-7D0001
Revision: 0
Order code: 413915

Page 2 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0

Ex p Control unit
SILASpz
Table of contents
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 3 of 88
0Table of contents
0Table of contents........................................................................................................ 3
1About these operating instructions ............................................................................. 7
Highlighting in the document ......................................................................................... 8
Warnings ........................................................................................................................ 8
Symbols and icons ......................................................................................................... 9
Technical changes.......................................................................................................... 9
Languages...................................................................................................................... 9
2Safety ...................................................................................................................... 10
Intended use ................................................................................................................ 10
Exclusive purpose ........................................................................................................ 10
Improper use................................................................................................................ 10
Warranty ...................................................................................................................... 10
Safety instructions....................................................................................................... 11
General ........................................................................................................................ 11
Safety instructions for operation.................................................................................. 11
Avoidance of damage to property ................................................................................. 12
Short circuit due to improper connection ..................................................................... 12
Triggering the safety function....................................................................................... 12
EMC-compliant connection.......................................................................................... 12
Storage at an excessively high temperature ................................................................. 12
Aggressive cleaning agents .......................................................................................... 13
Danger to health due to improper disposal................................................................... 13
Obligations of the owner............................................................................................... 13
Instructions for use ...................................................................................................... 13
Marking and test certificate ......................................................................................... 14
Ex p control unit SILAS, type A7-37S2-2111/*520 ........................................................ 14
Standards complied with ............................................................................................. 14
Ex p control unit SILAS, type A7-37S2-2111/*520 ........................................................ 14

Table of contents
Ex p Control unit
SILASpz
Page 4 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
3Product description.................................................................................................. 16
General information ..................................................................................................... 16
Ex p control units SILAS ............................................................................................... 16
SILAS design, type A7-37S2-2111/*520 ....................................................................... 17
Accessories.................................................................................................................. 18
Valve fuse..................................................................................................................... 18
Pressure outlet............................................................................................................. 18
Purge gas valve ............................................................................................................ 18
p-operator panel .......................................................................................................... 18
Programming switch .................................................................................................... 19
Programming cable ...................................................................................................... 19
4Transport and storage .............................................................................................. 20
Scope of delivery.......................................................................................................... 20
Packaging..................................................................................................................... 20
Transport ..................................................................................................................... 20
Storage ........................................................................................................................ 21
Disposal ....................................................................................................................... 21
5Installation............................................................................................................... 22
Installation Ex p control unit, type A7-37S2-2111/*520................................................ 22
Installation of the pressure outlet ................................................................................ 22
Assembly "Internal mounting kit, type 05-0091-0275" ................................................. 23
Assembly "External mounting kit, type 05-0091-0280"................................................. 24
Installation purging gas supply..................................................................................... 25
Version G1/4” ............................................................................................................... 26
Version G1/2” ............................................................................................................... 27
Version G1/4” (Dust application)................................................................................... 28
Pneumatic Connections ............................................................................................... 29
Pneumatic connections SILAS, type A7-37S2-2111/*520 ............................................. 29
Typical installations ..................................................................................................... 29
Typical arrangement - outside installation / gas application ........................................ 30
Typical arrangement - inside installation / gas application .......................................... 31
Typical arrangement - outside installation / dust application....................................... 32
Typical arrangement - inside installation / dust application......................................... 33
6Electrical connections .............................................................................................. 34
General ........................................................................................................................ 35
Connection notes ......................................................................................................... 35
EMC-compliant connection.......................................................................................... 36
Pre-Fuse ...................................................................................................................... 37
Inductive loads............................................................................................................. 38
Electrical wiring SILAS ................................................................................................. 39
“Ex e” connection terminals ......................................................................................... 40
Connection terminals “Ex i”.......................................................................................... 44

Ex p Control unit
SILASpz
Table of contents
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 5 of 88
7Operation................................................................................................................. 48
WEB interface .............................................................................................................. 48
Adjusting the LAN connection ...................................................................................... 48
Operation of the WEB interface .................................................................................... 50
Logging onto the WEB interface.................................................................................... 50
Navigation in the WEB interface ................................................................................... 50
Input of parameters...................................................................................................... 51
LED Indicators.............................................................................................................. 51
Menu structure WEB-Interface..................................................................................... 52
WEB-Interface operating menu .................................................................................... 53
Purge parameter .......................................................................................................... 53
Start page .................................................................................................................... 56
Status .......................................................................................................................... 56
Messages..................................................................................................................... 56
Parameter .................................................................................................................... 57
Temperature sensors ................................................................................................... 57
Extended...................................................................................................................... 59
Menu „Network“........................................................................................................... 62
Menu „Language“......................................................................................................... 62
System status .............................................................................................................. 63
Reading container data ................................................................................................ 64
8Commissioning......................................................................................................... 65
General ........................................................................................................................ 65
Sequence for the settings ............................................................................................ 65
Parameterization of purge gas valve............................................................................. 65
Setting for "Leakage air compensation" digital valves.................................................. 66
Configuration for gas applications................................................................................ 66
Ex p settings –Manual purge ....................................................................................... 66
Ex p settings –Automatic purge................................................................................... 70
Configuration for dust applications .............................................................................. 73
Ex p settings................................................................................................................. 73
9Functional test and procedure .................................................................................. 75
Safety during operation................................................................................................ 75
Functional flow diagram for the Ex p control station .................................................... 75
Ex p control flow chart.................................................................................................. 75
Functional flow diagram –dust.................................................................................... 76

Table of contents
Ex p Control unit
SILASpz
Page 6 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
10 Maintenance and care .............................................................................................. 77
Types of purging gas..................................................................................................... 77
Maintenance work........................................................................................................ 77
Maintenance intervals.................................................................................................. 77
Visual inspection .......................................................................................................... 78
Cleaning ....................................................................................................................... 78
Regular maintenance ................................................................................................... 78
Repairs......................................................................................................................... 78
Faults and troubleshooting .......................................................................................... 78
Faults........................................................................................................................... 79
Error messages ............................................................................................................ 81
11 Technical data.......................................................................................................... 83
12 Order numbers ......................................................................................................... 84
Ex p control unit SILAS, standard ................................................................................. 84
Pressure outlet module ................................................................................................ 84
Valve fuse..................................................................................................................... 84
Purge gas valve ............................................................................................................ 84
Operator panel ............................................................................................................. 84
Installation accessories ............................................................................................... 84
Protective circuits ........................................................................................................ 84
13 Annex....................................................................................................................... 85
Purge diagram .............................................................................................................. 85
Sequence diagram........................................................................................................ 86
Dimensions .................................................................................................................. 87
Ex p control unit SILAS, type A7-37S2-2111/*520 ........................................................ 87
Pressure outlet, type 17-51P3-1603............................................................................. 87
Software packages used .............................................................................................. 87
14 Declaration of conformity ......................................................................................... 88
Ex p control unit SILAS, type A7-37S2-*1*1/****......................................................... 88

Ex p Control unit
SILASpz
About these operating instructions
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 7 of 88
1About these operating instructions
Please read carefully before putting the device into operation.
Please observe the corresponding user manual.
This manual contains the information required for using the control unit in
accordance with its intended purpose. It is addressed to technically qualified
personnel.
Familiarity with and the technically perfect implementation of the safety
instructions and warnings described in this manual are preconditions for safe
installation and commissioning. The safety notes and warnings in these
operating instructions are given in a general manner and only qualified
personnel will have the necessary know how to interpret and implement them
correctly in specific individual cases.
These operating instructions are an integral part of the scope of delivery even if,
for logistical reasons, they can be ordered and delivered separately.
Should you require further information, please request the required
information from your local or responsible BARTEC branch. Read the
operating instructions and in particular the safety instructions carefully
before using the device.
Keep the operating instructions during the entire service life of the
device.
Make the brief instructions accessible to all persons entrusted with
handling the device.

About these operating instructions
Ex p Control unit
SILASpz
Page 8 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
Highlighting in the document
Warnings
Warnings are used in this user manual to warn of property damage and personal
injury.
Always read and follow these warnings.
Warnings are specially highlighted in this user manual and identified by symbols:
DANGER
DANGER indicates a hazardous situation which, if safety measures are not
observed, may result in death or serious injuries with permanent damage.
WARNING
WARNING indicates a hazardous situation which, if safety measures are not
observed, may result in serious injuries without permanent damage.
CAUTION
CAUTION indicates a hazardous situation which, if safety measures are not
observed, can result in minor injuries.
ATTENTION
ATTENTION indicates a hazardous situation which, if the safety measures
are not observed, may result in damage to property.
Explanation of the structure of a warning notice
WARNING WORD
Identifies the source of danger, cause of danger or type of danger
Consequence of non-compliance with the described safety measure.
Safety measure
Example of a warning notice
DANGER
Operation of the control unit in the case of damage!
Death or serious injury.
Put the control unit out of operation and secure it against restart.

Ex p Control unit
SILASpz
About these operating instructions
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 9 of 88
Symbols and icons
Symbol
Explanation
Important notices and information for the effective, efficient and
environmentally friendly use of the product.
Ex application; this symbol indicates special information for Ex
applications
Table 1: Symbols and icons
Technical changes
The current versions of the datasheets, operating instructions, certificates and
EC declarations of conformity as well as information on new accessories can be
downloaded from www.bartec.de under “Products” in the product area “Control
and Connection Equipment”, or requested directly from BARTEC GmbH.
Languages
The original user manual is written in German. All other available languages are
translations of the original user manual.
The user manual is available in German and English. If further languages are
required, these must be requested from BARTEC or stated when placing the
order.

Safety
Ex p Control unit
SILASpz
Page 10 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
2Safety
Intended use
Exclusive purpose
The Ex p control unit SILAS serves exclusively as a controlling and monitoring
device for pressurized enclosures and is intended for use in explosion group II,
category 2GD (EPL Gb and EPL Db) and temperature class T4 or T5 or for use in
dusty environments with surface temperatures of T95 °C or T130 °C.
Furthermore, the safety function of the Ex p control unit satisfies the
requirements on SIL 2 according to IEC 61508 and performance level “d”
according to EN ISO 13849-1. The permissible operating data of the device used
must be observed.
Improper use
Any other use is not in accordance with the intended purpose and may lead to
damage and accidents. The manufacturer will not be liable for any use beyond
that of its intended purpose.
Warranty
WARNING
UNAUTHORISED MODIFICATIONS AND/OR ALTERATIONS TO THE CONTROL
SYSTEM.
Explosion protection as well as design and manufacture in line with strain
and safety requirements are no longer guaranteed.
Before making any modifications or alterations, contact the
manufacturer to obtain written approval.
Use only original spare parts and original wearing parts.
Assumption of warranty
The manufacturer assumes the complete warranty only and
exclusively for the spare parts ordered from the manufacturer.
As a basic rule, our “General Terms, Conditions of Sale, and Delivery” apply. They
are available to the managing operator on conclusion of contract at the latest.
Warranty and liability claims for personal injury and damage to property are
excluded if they are due to one or several of the following reasons:
Improper use of the Ex p control unit.
Incorrect installation, commissioning, operation and maintenance of the
Ex p control unit.
Non-compliance with the instructions in the manual with respect to
transport, storage, assembly, commissioning, operation and maintenance.
Unauthorized structural changes to the Ex p control unit.
Inadequate monitoring of parts that are subject to wear.
Improperly performed repairs.
Disasters caused by foreign bodies and force majeure.

Ex p Control unit
SILASpz
Safety
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 11 of 88
We guarantee the Ex p control unit and its accessories for a period of one year
starting on the date of delivery from the Bad Mergentheim plant. This warranty
covers all parts of the delivery and is restricted to the replacement free of charge
or the repair of the defective parts in our Bad Mergentheim plant. Any packaging
delivered here should be kept where possible. If necessary, the goods should be
sent to us after written agreement. There is no entitlement to rectification at the
site of installation.
Safety instructions
General
Do not dry wipe or clean devices in hazardous areas!
Do not open devices in hazardous areas.
The general statutory regulations or guidelines relating to safety at work,
accident prevention and environmental protection legislation must be
observed, e.g. the German Industrial Health and Safety Ordinance
(BetrSichV) or the applicable national ordinances.
Wear suitable clothing and footwear in view of the risk of dangerous
electrostatic charges.
Avoid exposure to heat outside the specified temperature range (see
Chapter “General technical data”).
Avoid exposure to moisture.
Safety instructions for operation
Commissioning
Before commissioning, check that all components and documents are
available.
Inspection
Under EN/IEC 60079-17 / ГОСТ IEC 60079-17-2013, the owner of electrical
systems in hazardous areas is obliged to have them checked by a qualified
electrician to ensure that they are in a proper condition.
Maintenance
For electrical systems, the relevant installation and operating regulations
must be observed (e.g. Directive 99/92/EC, Directive 2014/34/EUEC,
BetrSichV or the nationally applicable ordinances EN/IEC 60079-14 /
ГОСТ IEC 60079-14-2013 and the DIN VDE 0100, TR TS 012/2011 series)!
Please observe the national waste disposal regulations for disposal.
Servicing
Regular servicing is not necessary if the device is operated correctly in
accordance with the installation instructions and ambient conditions.
BARTEC recommends annual servicing and inspection.
See Chapter “Maintenance and care”.

Safety
Ex p Control unit
SILASpz
Page 12 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
Repairs
Only authorized persons working in accordance with the latest
development in technology and using original spare parts may do repairs
on explosion-protected equipment. The applicable provisions must be
observed.
Repairs must be carried out in accordance with EN / IEC 60079-19 /
ГОСТ 31610.19-2014.
For SIL-qualified devices, only a corresponding electronics module with
SIL qualification may be used.
All application settings must be re-entered. Therefore, you must conduct a
restart after a repair. If you have saved the data of parameter assignment
the first time you commissioned the Ex p control unit, you can transfer
them back to the replacement control unit. Detailed information on the
replacement of spare parts can be found in these operating instructions.
After restart or transfer of the parameter assignment data, you must verify
the parameters. Only then will the device be ready for operation again.
For Ex applications, only one device and one electronic module may be
used with corresponding Ex approval. Order the spare parts from your local
representative. The serial number can be found on the type plate of the
device, inside the enclosure.
Avoidance of damage to property
Short circuit due to improper connection
An incorrect connection of the power supply will destroy the electronics and void
the warranty.
Triggering the safety function
Switching on again too quickly after switching off can cause internal voltage
peaks in the power supply unit and thus trigger a safety function. After switching
off the voltage path, wait at least 30 seconds before switching on again.
EMC-compliant connection
For the safe function of the Ex p control unit it is important to carry out the wiring
in accordance with EMC. This includes observing the chapter Electrical
connections with regard to EMC-compliant wiring and inductive loads.
Storage at an excessively high temperature
Store the Ex p control unit at the intended storage temperature since otherwise
damage to the electronics or seals may occur. Ensure adequate air conditioning
at high storage temperatures.

Ex p Control unit
SILASpz
Safety
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 13 of 88
Aggressive cleaning agents
When selecting the correct cleaning agent, it is essential that it is suitable for
use since otherwise damage may occur to seals and connections. Combustible
products are generally not permitted.
Danger to health due to improper disposal
According to the European WEEE Directive, electrical and electronic equipment
may not be disposed of with household waste. Their components must be sent
separately for recycling or disposal because toxic and hazardous components
can cause long-term damage to health and the environment if not disposed of
properly.
As consumers, you are obliged under the Electrical and Electronic Equipment Act
(ElektroG) to return electrical and electronic equipment at the end of its
serviceable life free of charge to the manufacturer, the point of sale or to public
collection points set up for this purpose. Details of this are regulated by the
respective national law. The symbol on the product, the operating instructions
or/and the packaging refers to these regulations. With this type of material
separation, recycling and disposal of old devices, you make an important
contribution to the protection of our environment.
Obligations of the owner
The owner undertakes to restrict permission to work with and on the SILAS
control unit to people who:
are familiar with the basic regulations on safety and accident prevention
and have been instructed in the use of the SILAS control unit;
have read and understood the documentation, the chapter on safety and
the warnings.
The owner must check that the safety regulations and accident prevention
rules valid for the respective application are observed.
Instructions for use
The overvoltage category II of the non-intrinsically safe circuits according
to IEC 60664-1 must be observed.
The warning “WARNING –DO NOT OPEN UNDER VOLTAGE” must be part of
the external marking of the entire electrical device or the enclosure must
have a locking system to prevent the fuses from being energized during
replacement.

Safety
Ex p Control unit
SILASpz
Page 14 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
Marking and test certificate
The Ex p control unit is approved for the following areas.
Ex p control unit SILAS, type A7-37S2-2111/*520
ATEX (Europe)
Marking
II 3G Ex ec mc ic [ic pzc] IIC T5/T4 Gb
II 3D Ex tc [ic pzc] IIIC T130 °C / T95 °C Db
Test certificate
BVS 19 ATEX E 016 X
IECEx (International)
Marking
Ex ec mc ic [ic pzc] IIC T5/T4 Gb
Ex tc [ic pzc] IIIC T130 °C / T95 °C Db
Test certificate
IECEx BVS 19.0038X
EAC (Eurasian Economic Union)
Marking
2Ex ic e mc [ic pz] [ia Ga] IIC T5 Gc X
2Ex ic e mc [ic pz] [ia Ga] IIC T4 Gb X
Ex tc [ic pz] IIIC T95 °C Dc X
Ex tc [ib pz] IIIC T130 °C Dc X
Test certificate
ЕАЭС RU С-DE.АЖ58.В.01809/21
Standards complied with
Ex p control unit SILAS, type A7-37S2-2111/*520
Standard
Designation
EN IEC 60079-0:2018/AC:2020
IEC 60079-0:2011 Edition: 6.0
ГОСТ 31610.0-2014
Explosive atmospheres –Part 0: General
requirements
EN 60079-2:2014
IEC 60079-2:2007 Edition: 5.0
ГОСТ IEC 60079-2-2011
Explosive atmospheres - Part 2: Equipment
protection by pressurised enclosure “p”
EN 60079-7:2015/A1:2018
IEC 60079-7:2006 Edition: 4.0
ГОСТ РМЭК 60079-7-2012
Explosive atmospheres - Part 7: Equipment
protection by increased safety “e”
EN 60079-11:2012
IEC 60079-11:2011 Edition: 6.0
ГОСТ 31610.11-2014
Explosive atmospheres - Part 11: Equipment
protection by intrinsic safety “i”
EN 60079-18:2015/A1:2017
IEC 60079-18:2014 Edition: 4.0
ГОСТ РМЭК 60079-18-2012
Explosive atmospheres - Part 18: Equipment
protection by cast encapsulation “m”

Ex p Control unit
SILASpz
Safety
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 15 of 88
Standard
Designation
EN 60079-31:2014
IEC 60079-31:2013 Edition: 2.0
ГОСТ IEC 60079-31-2013
Explosive atmospheres - Part 31:
Equipment dust ignition protection by enclosure
“t”
EN 61010-1:2010
IEC 61010-1:2010 Edition 3.0
Safety requirements for electrical equipment for
measurement, control and laboratory use –Part 1:
General requirements
EN 61000-6-4:2007 + A1:2011
IEC 61000-6-4:2018 Edition 3.0
Electromagnetic compatibility (EMC) –
Part 6-4: Generic standards –Emission standard
for industrial environments
EN 61000-3-2:2014
IEC 61000-3-2:2018 Edition 5.0
Electromagnetic compatibility (EMC) –
Part 3-2: Limits –Limits for harmonic current
emissions (equipment input current <= 16 A per
phase)
EN 61000-3-3:2013
EN 61000-3-3:2013 +
AMD1:2017 Edition 3.1
Electromagnetic compatibility (EMC) –
Part 3-3: Limits –Limitations of voltage changes,
voltage fluctuations and flicker in public low-
voltage supply systems for equipment with rated
current <= 16 A per phase, and not subject to
conditional connection
EN 61326-1:2013
IEC 61326-1:2012
Electrical equipment for measurement, control
and laboratory use –EMC requirements –Part 1:
General requirements
EN ISO 13849-1:2015
Safety of machinery - Safety-related parts of
control systems - Part 1: General principles for
design
EN ISO 13849-2:2012
Safety of machinery - Safety-related parts of
control systems - Part 2: Validation
DIN EN 62061:2016
IEC 62061:2015
Safety of machinery - Functional safety of safety-
related of electrical, electronic and programmable
electronic control systems

Product description
Ex p Control unit
SILASpz
Page 16 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
3Product description
General information
The Ex p type of protection, referred to as “pressurized enclosure”, is based on
the measure of purging out any explosive gases that are in a closed enclosure
and then generating and maintaining a level of pressure that is higher than that
of the ambient atmosphere. As the pressure inside the enclosure is higher as the
atmospheric pressure, it is not possible at any time for explosive gases to
penetrate the inside of the enclosure. This creates an Ex-free area in which
electrical devices that are not themselves explosion-proof can be mounted and
operated.
The SILAS control units described in these operating instructions function on the
principle of “pressurized enclosure with leakage loss compensation”.
Specifically, this means that an overpressure in an enclosure is maintained by
the addition of purging gas to compensate for the leakage losses from the
enclosure.
To ensure that an explosive atmosphere that has penetrated during downtimes
cannot become a hazard, the enclosure must be flushed with purging gas
(compressed air or inert gas) before commissioning. The quantity depends on the
inspection carried out during initial commissioning. The rate of flow is measured
or determined at the outlet of the pressurized enclosure.
Since a safe state in the enclosure is only reached when the operation phase is
started, it is necessary to use explosion-proof versions of the SILAS control unit
with its system components.
Ex p control units SILAS
The control unit SILAS with its system components is an
automatic controller for monitoring, controlling and
regulating pressurized enclosures in the hazardous
areas of Zone 2 and Zone 22.
The control unit SILAS is suitable for all standard
applications for pressurized enclosures of Zone 2 and
Zone 22.
The electrical installed parts inside the pressurized
enclosure are enabled by the control unit SILAS directly or by an additional
switching device.
Once the control unit SILAS, the purging gas valve and the pressure outlet have
been mounted on the pressurized enclosure and after connection of mains
voltage and purging gas, the pressurized system starts automatically.The control
unit SILAS regulates the purging gas flow and the pressure inside the enclosure
during the purging phase. When the operating phase is initiated, the SILAS
control unit automatically activates the components mounted in the pressurized
enclosure.The pressure inside the pressurized enclosure is maintained
automatically during the operating phase and any leakage losses are
compensated

Ex p Control unit
SILASpz
Product description
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 17 of 88
SILAS design, type A7-37S2-2111/*520
The enclosure of variant two is available for the Ex p
control unit SILAS and is made of stainless steel.
In this enclosure variant, the associated pressure
measurement card is integrated.
Ex p control units of this enclosure variant can be
mounted internally or externally on the pressurized
enclosure.
In terms of explosion protection, the enclosure provides
Ex e protection for gas and Ex t protection for dust.
Item
Designation
Control electronics SILAS
Protection enclosure
Outer earthing connection
Ex e cable entry
Ex i cable entry
Pressure measurement connections

Product description
Ex p Control unit
SILASpz
Page 18 of 88 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Rev. 0
Accessories
Valve fuse
Valve fuse, type 05-0080-10**
The valve fuse serves to secure the connected purging gas valve
and is connected on the Ex e board of the control unit.
Pressure outlet
Pressure outlet, Type 17-51P3-1604
The pressure outlet serves as a pressure relief valve for Ex pzc
systems
Purge gas valve
Purge gas valve, Type 05-0056-****
Different versions as digital purging gas valve (open/close)
with integrated manual leakage air needle valve or
proportional purging gas valve (regulating).
p-operator panel
p-Operator Panel, Type 17-51P5-*1111
The p-operator panel is a visualization unit for the control unit
SILAS or SILAS. It can be optionally connected and is used to
display the system states and to parameterize the control units.
By means of mounting brackets, it can be used both as an add-
on or in basic variant for installation.
It can be connected or disconnected during operation and it is therefore not
necessary for it to be permanently connected to the control unit.
For the p-operator panel, the application is use is described in a separate
operating manual.

Ex p Control unit
SILASpz
Product description
Rev. 0 A1-37S2-7D0001_pz_Manual_Exp-Control-Unit_20210923_0_en.docx Page 19 of 88
Programming switch
The programming switch must be connected to the control unit
in order to change parameters and switching values.
The control unit SILAS does not accept values, which are
changed without an active connected programming switch.
Programming cable
The programming cable is used to connect the Ex p control unit
to the PC. This must be connected to the control unit and PC in
order to change parameters and switching values.
Table of contents
Other Bartec Control Unit manuals

Bartec
Bartec PBTC-200 Specification sheet

Bartec
Bartec 17-A1Z0-0005 User manual

Bartec
Bartec 07-3323-1.00 Quick start guide

Bartec
Bartec APEXmv 07-37A2-2211 730 Series User manual

Bartec
Bartec PBTC-300 Specification sheet

Bartec
Bartec 07-61.1 Series Quick start guide

Bartec
Bartec VOLUTANK Petro 3003 User manual

Bartec
Bartec RFID Snap-on Module User manual

Bartec
Bartec APEXpy 07-37A2-2111/ 520Series User manual

Bartec
Bartec 17-A1Z0-0005 User manual