INSTRUCTIONS FOR USE EN
•Place the angle indicator on the tool and quickly press button (S/S) to start tightening. The angle indicator is fitted with a magnet,
to provide perfect stability (picture 2-o).
•When 80% of the selected angle is reached, the first green LED will turn on and the buzzer will sound.
•When the set angle value is reached, the red LED will turn on.
•To store the value of the torque angle, press button M.
CAUTION:
If the tightening process is interrupted for a few seconds, the display will blink, confirming that the required angle has
been reached. To resume tightening, press button (S/S). To zero the device, press button C.
•To start a new tightening operation, press button S/S.
If the display is not used for approximately 2 minutes, it will automatically turn off.
SETTING UP MENU
Keep button S/S pressed to enter the configuration menu. Press button S/S several times to enter the menus: CHANGING
TORQUE DIRECTION, TORQUE MEMORIES AND RESETTING TORQUE MEMORIES.
CHANGING TORQUE DIRECTION MENU
-The display will show PoS for the clockwise direction of rotation, and nEG for the anticlockwise direction
of rotation respectively.
-
Press buttons Kand
7to
change the direction of rotation.
-To quit the menu, press button (S/S) several times.
TORQUE MEMORIES MENU
-This menu provides the values of the measured and stored torque angles (up to 50 values stored).
-If no values have been stored, the display will show nonE.
-
Whenever buttons Kand 7are pressed, the display will show the stored values of the torque angle.
-To delete one of the stored values, press button C twice.
-To quit the menu, press button (S/S) several times.
RESETTING TORQUE MEMORIES MENU
-This menu allows all the values stored in the TORQUE MEMORIES MENU to be deleted.
-The display will show ClrA
-To delete all the stored values, press button C.
-The display will show no?
-To delete all the stored values, press button C. To cancel the operation, press button S/S.
-To quit the menu, press button S/S twice.
ERROR MESSAGES
-Er4 indicates that the value has not been set correctly. Press button C to repeat the operation. Do not move the
angle indicator while setting.
-Er5 indicates that the angle indicator is not working correctly. Press the RESET button.
-Er--- indicates that the angle indicator was rotated too quickly during a measurement. Press button C to repeat the
operation.
-Full indicates that no data can be stored in the memory; the memory is full. Delete some of the 50 stored data.
RESET
-If the angle indicator is not working correctly, press the RESET button to zero the device (picture 2-r). The angle
indicator can also be zeroed by removing the batteries.